Low-Intensity Focused Ultrasound for Facial Volume Restoration: A Retrospective Case Series

Purpose: Loss of facial volume due to aging or lipoatrophy significantly impacts appearance and psychosocial well-being. This study reports preliminary clinical outcomes of a non-injectable alternative: low-intensity, linear-focused ultrasound for facial volume restoration. Patients and methods: This retrospective case series included three female patients (aged 39, 43, and 52 years) with temporal or malar hollowing who declined injectables. All were treated in 2024 at a single aesthetic center using the LinearZ device (Jeisys Medical Inc., South Korea). Treatment was individualized by region (0.2–0.4 J, 20–100 shots, 4.5 mm cartridges). Standardized photographs were obtained at baseline and follow-up (3 months for all patients, and up to 6 months for one). A board-certified dermatologist blinded to the procedure assessed outcomes by comparing photographs and patient feedback. Results: Patient 1 (39 years) showed sustained improvement in bilateral temporal volume and contour at 3 and 6 months. Patient 2 (52 years) demonstrated increased left cheek volume with improved symmetry at 3 months. Patient 3 (43 years) exhibited enhanced midface volume, mandibular contour, and reduced laxity following dual-region treatment at 3 months. No adverse events or safety concerns were reported across patients. Improvements appeared gradually, consistent with remodeling processes rather than immediate filling. Conclusion: A single session of low-intensity, linear-focused ultrasound was associated with visible improvement in temporal and malar volume, as well as mandibular contour, without adverse events. These findings support the potential of subablative ultrasound as a safer, non-injectable alternative for mild to moderate facial volume loss. However, the small sample size, lack of volumetric measurements, and short follow-up limit generalizability. Controlled trials with objective endpoints and long-term evaluation are warranted.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-24
DOI
https://doi.org/10.21203/rs.3.rs-11684994/v1
Primary Topic
Facial Rejuvenation and Surgery Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Low-Intensity Focused Ultrasound for Facial Volume Restoration: A Retrospective Case Series

Yuri Yogya
5 links
Research Square
Facial Rejuvenation and Surgery Techniques
preprint

Low-Intensity Focused Ultrasound for Facial Volume Restoration: A Retrospective Case Series

Yuri Yogya
preprint en

Abstract

Purpose: Loss of facial volume due to aging or lipoatrophy significantly impacts appearance and psychosocial well-being. This study reports preliminary clinical outcomes of a non-injectable alternative: low-intensity, linear-focused ultrasound for facial volume restoration. Patients and methods: This retrospective case series included three female patients (aged 39, 43, and 52 years) with temporal or malar hollowing who declined injectables. All were treated in 2024 at a single aesthetic center using the LinearZ device (Jeisys Medical Inc., South Korea). Treatment was individualized by region (0.2–0.4 J, 20–100 shots, 4.5 mm cartridges). Standardized photographs were obtained at baseline and follow-up (3 months for all patients, and up to 6 months for one). A board-certified dermatologist blinded to the procedure assessed outcomes by comparing photographs and patient feedback. Results: Patient 1 (39 years) showed sustained improvement in bilateral temporal volume and contour at 3 and 6 months. Patient 2 (52 years) demonstrated increased left cheek volume with improved symmetry at 3 months. Patient 3 (43 years) exhibited enhanced midface volume, mandibular contour, and reduced laxity following dual-region treatment at 3 months. No adverse events or safety concerns were reported across patients. Improvements appeared gradually, consistent with remodeling processes rather than immediate filling. Conclusion: A single session of low-intensity, linear-focused ultrasound was associated with visible improvement in temporal and malar volume, as well as mandibular contour, without adverse events. These findings support the potential of subablative ultrasound as a safer, non-injectable alternative for mild to moderate facial volume loss. However, the small sample size, lack of volumetric measurements, and short follow-up limit generalizability. Controlled trials with objective endpoints and long-term evaluation are warranted.

Research Square
Padjadjaran University (ID)
Good health and well-being
Facial Rejuvenation and Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon