Do Documented Risk Controls Hold? A Pre-Registered Method for Verifying Control Performance and Hand-Off Responsibility in Multi-Supplier Clinical AI Workflows

Primary care practices increasingly chain AI tools from several suppliers, such as triage, ambient scribes, automated filing and coding, and task agents. Governance work on clinical AI has so far taken a single system, or a system together with its human reviewer, as the unit of analysis. The risk in a multi-supplier workflow, however, sits in the controls that each supplier documents and in the hand-offs that no supplier owns. The UK National Commission into the Regulation of AI in Healthcare (September 2026) asks manufacturers to specify the controls needed for safe deployment and contracts to allocate responsibility for delivering them; the government accepted these recommendations in October 2026. This paper presents a pre-registered method for checking both. Each documented control is classified against its documented effectiveness and against a severity-based floor using Wilson intervals on walkthrough counts from synthetic test cases, with exact power and the walkthrough sample size required. Parameter uncertainty is propagated through the workflow in closed form, separating escape to the record from undetected escape, and every gap is mapped to a draft hazard-log entry under the English clinical risk management standards DCB0129 and DCB0160. In an invented six-step workflow with six controls and ten fault types, three controls fell below their documented effectiveness, and no control could be shown to meet a floor of 0.80 with 40 walkthrough cases; about 100 cases per control would be needed. Three of five hand-offs had no owner, one fault type had no control, and two fault types were covered only by a retrospective audit. Full correlation between a scribe confidence flag and clinician review removed the benefit of the second barrier. The method turns control performance and hand-off responsibility into checkable statements; all inputs of the worked example are invented.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-24
DOI
https://doi.org/10.21203/rs.3.rs-11325071/v1
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Do Documented Risk Controls Hold? A Pre-Registered Method for Verifying Control Performance and Hand-Off Responsibility in Multi-Supplier Clinical AI Workflows

Thomas Frese, Florian Odilo Stummer
1 links
Research Square
Artificial Intelligence in Healthcare and Education
preprint

Do Documented Risk Controls Hold? A Pre-Registered Method for Verifying Control Performance and Hand-Off Responsibility in Multi-Supplier Clinical AI Workflows

Thomas Frese, Florian Odilo Stummer
preprint en

Abstract

Primary care practices increasingly chain AI tools from several suppliers, such as triage, ambient scribes, automated filing and coding, and task agents. Governance work on clinical AI has so far taken a single system, or a system together with its human reviewer, as the unit of analysis. The risk in a multi-supplier workflow, however, sits in the controls that each supplier documents and in the hand-offs that no supplier owns. The UK National Commission into the Regulation of AI in Healthcare (September 2026) asks manufacturers to specify the controls needed for safe deployment and contracts to allocate responsibility for delivering them; the government accepted these recommendations in October 2026. This paper presents a pre-registered method for checking both. Each documented control is classified against its documented effectiveness and against a severity-based floor using Wilson intervals on walkthrough counts from synthetic test cases, with exact power and the walkthrough sample size required. Parameter uncertainty is propagated through the workflow in closed form, separating escape to the record from undetected escape, and every gap is mapped to a draft hazard-log entry under the English clinical risk management standards DCB0129 and DCB0160. In an invented six-step workflow with six controls and ten fault types, three controls fell below their documented effectiveness, and no control could be shown to meet a floor of 0.80 with 40 walkthrough cases; about 100 cases per control would be needed. Three of five hand-offs had no owner, one fault type had no control, and two fault types were covered only by a retrospective audit. Full correlation between a scribe confidence flag and clinician review removed the benefit of the second barrier. The method turns control performance and hand-off responsibility into checkable statements; all inputs of the worked example are invented.

Research Square
Martin Luther University Halle-Wittenberg (DE)
Good health and well-being
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon