Explainable and Uncertainty-Aware Machine Learning for Groundwater Hardness Screening in Dadra and Nagar Haveli and Daman and Diu, India: A Station-Grouped Evaluation Against a Conductivity Baseline

Machine learning is widely used to screen groundwater quality, but models are rarely compared with a simple conductivity baseline or validated spatially. We analysed 262 pre-monsoon records (2000–2021) from 33 Central Ground Water Board stations in Dadra and Nagar Haveli (DNH), Daman and Diu, India (239 with total hardness), to classify exceedance of the BIS acceptable limit (200 mg/L). Logistic regression, random forest and XGBoost were compared with an electrical-conductivity (EC) baseline under repeated station-grouped cross-validation with station-level bootstrap intervals; calcium and magnesium were excluded. With the full 11-input laboratory suite, ROC-AUC in DNH was 0.92 for EC and 0.94–0.98 for the models (territory 0.87 against 0.89–0.91), partly reflecting ionic balance. With low-cost inputs no model reliably exceeded EC. After Holm adjustment no advantage was significant, which with 22 to 33 stations is inconclusive and not evidence of equivalence. Spatially blocked validation lowered the tree models' territory AUC by 0.02 to 0.05, to the EC level. Best EC cut-offs differed between districts (432 and 701 µS/cm) with overlapping intervals. Random-forest probabilities were approximately calibrated in slope. Conformal sets (nominal 90%) gave 92.9% coverage with 38.9% of records uncertain, and flagged hard records no better than a matched probability band. A rule-based scheme, driven mainly by each station's latest observed hardness, assigned 13 stations to confirmatory re-testing, 7 to enhanced monitoring, 9 to routine monitoring and 4 to re-baseline sampling. Nitrate and fluoride were unavailable.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-24
DOI
https://doi.org/10.5281/zenodo.24492408
Primary Topic
Water Quality and Pollution Assessment
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Explainable and Uncertainty-Aware Machine Learning for Groundwater Hardness Screening in Dadra and Nagar Haveli and Daman and Diu, India: A Station-Grouped Evaluation Against a Conductivity Baseline

Paras Palawat
4 links
Zenodo (CERN European Organization for Nuclear Research)
Water Quality and Pollution Assessment
preprint

Explainable and Uncertainty-Aware Machine Learning for Groundwater Hardness Screening in Dadra and Nagar Haveli and Daman and Diu, India: A Station-Grouped Evaluation Against a Conductivity Baseline

Paras Palawat
preprint en

Abstract

Machine learning is widely used to screen groundwater quality, but models are rarely compared with a simple conductivity baseline or validated spatially. We analysed 262 pre-monsoon records (2000–2021) from 33 Central Ground Water Board stations in Dadra and Nagar Haveli (DNH), Daman and Diu, India (239 with total hardness), to classify exceedance of the BIS acceptable limit (200 mg/L). Logistic regression, random forest and XGBoost were compared with an electrical-conductivity (EC) baseline under repeated station-grouped cross-validation with station-level bootstrap intervals; calcium and magnesium were excluded. With the full 11-input laboratory suite, ROC-AUC in DNH was 0.92 for EC and 0.94–0.98 for the models (territory 0.87 against 0.89–0.91), partly reflecting ionic balance. With low-cost inputs no model reliably exceeded EC. After Holm adjustment no advantage was significant, which with 22 to 33 stations is inconclusive and not evidence of equivalence. Spatially blocked validation lowered the tree models' territory AUC by 0.02 to 0.05, to the EC level. Best EC cut-offs differed between districts (432 and 701 µS/cm) with overlapping intervals. Random-forest probabilities were approximately calibrated in slope. Conformal sets (nominal 90%) gave 92.9% coverage with 38.9% of records uncertain, and flagged hard records no better than a matched probability band. A rule-based scheme, driven mainly by each station's latest observed hardness, assigned 13 stations to confirmatory re-testing, 7 to enhanced monitoring, 9 to routine monitoring and 4 to re-baseline sampling. Nitrate and fluoride were unavailable.

Zenodo (CERN European Organization for Nuclear Research)
National Institution for Transforming India Aayog (IN)
Clean water and sanitation
Water Quality and Pollution Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Explainable and Uncertainty-Aware Machine Learning for Groundwater Hardness Screening in Dadra and Nagar Haveli and Daman and Diu, India: A Station-Grouped Evaluation Against a Conductivity Baseline — Paras Palawat · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS