High-Frequency Gallium Arsenide Self-Injection-Locked and Super-Regenerative Oscillator Radar Sensors for Noncontact Vital Sign Monitoring

Microwave and millimeter-wave radar enables noncontact vital-sign monitoring by detecting the small body-surface movements associated with respiration and heartbeat. Commercial patient monitors and contactless radar-based sleep monitors provide an established application context, motivating research into the circuitry and signal processing needed for compact noncontact sensors. Higher carrier frequencies increase the phase change produced by a given displacement and permit smaller antennas and circuit structures. However, realizing these benefits in an integrated sensor requires weak-motion sensitivity to be balanced against hardware complexity, power consumption, and signal-processing latency. Range and angular discrimination are also needed to distinguish targets at different locations. This dissertation develops W-band and D-band gallium arsenide (GaAs) radar sensors based on self-injection-locked (SIL) and super-regenerative-oscillator (SRO) architectures in 0.1-µm and 70-nm pseudomorphic high-electron-mobility-transistor technologies. Both architectures use the oscillator directly as a sensing element. In SIL operation, the reinjected echo encodes target motion as a variation in the locked oscillation frequency. In SRO operation, a periodic quench signal controls transient oscillation build-up, allowing the echo to modulate the pulse envelope. These mechanisms reduce the need for separate RF sensing and demodulation blocks. Two W-band SIL sensors integrate an oscillator, directional coupler, and substrate-integrated-waveguide monopole antenna. The first extracts a frequency-versus-time track using a short-time Fourier transform, followed by a fast Fourier transform (FFT) to identify respiration and heartbeat. The second incorporates a first-order millimeter-wave frequency differentiator that converts frequency modulation into amplitude modulation before digitization, enabling envelope detection followed by a single FFT. Both sensors demonstrate human vital-sign detection up to 0.9 m; the differentiator-based approach reduces measured post-processing time by approximately a factor of ten under the tested conditions. A W-band SRO sensor uses quench-controlled transient regeneration and envelope detection to recover actuator motion, respiration, and heartbeat. A two-chip pulsed configuration adds range estimation through time-domain cross-correlation while retaining FFT-based motion extraction. Extended measurements demonstrate metallic-target ranging up to 3.2 m and both human range and vital-sign detection up to 2.0 m. The architecture supports both observables, although acquisition constraints require separate records for range and motion estimation in the expanded experiments. The sensing concepts are extended to D-band in a 70-nm GaAs process. A SIL sensor with an integrated frequency differentiator provides a reference for a multimode SRO sensor characterized across quench frequencies, waveforms, and duty cycles. Under the technology-matched actuator comparison, the SRO achieves a 25.8-dB improvement in spectral amplitude relative to SIL operation. It also detects a 55-µm displacement at 1.5 Hz and extends human vital-sign detection to 1.4 m, establishing quench control as a key variable governing regenerative response. A D-band two-transmitter–one-receiver SRO array further introduces spatial selectivity. Relative timing between synchronized quench signals controls the effective inter-element excitation phase without conventional D-band RF phase shifters. Actuator measurements verify complementary enhancement and suppression near −1° and 28°. Two-subject measurements at 1 m demonstrate selective emphasis of the intended subject’s vital-sign components, with partial or strong suppression of the other subject depending on the steering state. Together, these results establish a progression from single-element SIL sensing to quench-controlled SRO systems with high sensitivity, range estimation, and angular selectivity. The work demonstrates how oscillator dynamics and integrated circuit design can jointly reduce sensing and demodulation complexity while extending noncontact monitoring capability.

Authors

Publication Details

Journal
Rutgers University Community Repository (Rutgers University)
Published
2026-11-24
DOI
https://doi.org/10.7282/t3-6780-5w70
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

High-Frequency Gallium Arsenide Self-Injection-Locked and Super-Regenerative Oscillator Radar Sensors for Noncontact Vital Sign Monitoring

Donglin Gao
2 links
Rutgers University Community Repository (Rutgers University)
Non-Invasive Vital Sign Monitoring
article

High-Frequency Gallium Arsenide Self-Injection-Locked and Super-Regenerative Oscillator Radar Sensors for Noncontact Vital Sign Monitoring

Donglin Gao
article en

Abstract

Microwave and millimeter-wave radar enables noncontact vital-sign monitoring by detecting the small body-surface movements associated with respiration and heartbeat. Commercial patient monitors and contactless radar-based sleep monitors provide an established application context, motivating research into the circuitry and signal processing needed for compact noncontact sensors. Higher carrier frequencies increase the phase change produced by a given displacement and permit smaller antennas and circuit structures. However, realizing these benefits in an integrated sensor requires weak-motion sensitivity to be balanced against hardware complexity, power consumption, and signal-processing latency. Range and angular discrimination are also needed to distinguish targets at different locations. This dissertation develops W-band and D-band gallium arsenide (GaAs) radar sensors based on self-injection-locked (SIL) and super-regenerative-oscillator (SRO) architectures in 0.1-µm and 70-nm pseudomorphic high-electron-mobility-transistor technologies. Both architectures use the oscillator directly as a sensing element. In SIL operation, the reinjected echo encodes target motion as a variation in the locked oscillation frequency. In SRO operation, a periodic quench signal controls transient oscillation build-up, allowing the echo to modulate the pulse envelope. These mechanisms reduce the need for separate RF sensing and demodulation blocks. Two W-band SIL sensors integrate an oscillator, directional coupler, and substrate-integrated-waveguide monopole antenna. The first extracts a frequency-versus-time track using a short-time Fourier transform, followed by a fast Fourier transform (FFT) to identify respiration and heartbeat. The second incorporates a first-order millimeter-wave frequency differentiator that converts frequency modulation into amplitude modulation before digitization, enabling envelope detection followed by a single FFT. Both sensors demonstrate human vital-sign detection up to 0.9 m; the differentiator-based approach reduces measured post-processing time by approximately a factor of ten under the tested conditions. A W-band SRO sensor uses quench-controlled transient regeneration and envelope detection to recover actuator motion, respiration, and heartbeat. A two-chip pulsed configuration adds range estimation through time-domain cross-correlation while retaining FFT-based motion extraction. Extended measurements demonstrate metallic-target ranging up to 3.2 m and both human range and vital-sign detection up to 2.0 m. The architecture supports both observables, although acquisition constraints require separate records for range and motion estimation in the expanded experiments. The sensing concepts are extended to D-band in a 70-nm GaAs process. A SIL sensor with an integrated frequency differentiator provides a reference for a multimode SRO sensor characterized across quench frequencies, waveforms, and duty cycles. Under the technology-matched actuator comparison, the SRO achieves a 25.8-dB improvement in spectral amplitude relative to SIL operation. It also detects a 55-µm displacement at 1.5 Hz and extends human vital-sign detection to 1.4 m, establishing quench control as a key variable governing regenerative response. A D-band two-transmitter–one-receiver SRO array further introduces spatial selectivity. Relative timing between synchronized quench signals controls the effective inter-element excitation phase without conventional D-band RF phase shifters. Actuator measurements verify complementary enhancement and suppression near −1° and 28°. Two-subject measurements at 1 m demonstrate selective emphasis of the intended subject’s vital-sign components, with partial or strong suppression of the other subject depending on the steering state. Together, these results establish a progression from single-element SIL sensing to quench-controlled SRO systems with high sensitivity, range estimation, and angular selectivity. The work demonstrates how oscillator dynamics and integrated circuit design can jointly reduce sensing and demodulation complexity while extending noncontact monitoring capability.

Rutgers University Community Repository (Rutgers University)
Good health and well-being
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon