Revised Reference Intervals for Serum Free Light Chains: Implementation at the Mayo Clinic
BACKGROUND: Universal reference intervals (RIs) for serum free light chains (FLCs) were established in 2002 using nephelometric instrumentation and early-generation reagents. Since then, assay platforms have evolved, renal effects have been characterized, and lot-to-lot drift has been documented. Large population-based studies also proposed age- and kidney function-stratified RIs. We evaluated whether legacy RIs remain appropriate following transition to a turbidimetric platform with stabilized reagents and established updated RIs. METHODS: Serum samples from 489 screened healthy adults were analyzed using the Optilite assay with stabilized κ calibrators. Samples with monoclonal proteins assayed by MASS-FIX, mass spectrometry-based monoclonal protein detection assay, were excluded. Central 99% RIs were derived using nonparametric methods. A secondary cohort of 106 individuals with chronic kidney disease (CKD) was analyzed to evaluate the effect of renal function. To assess clinical impact, 2025 clinical results, including >20 000 MASS-FIX-negative samples, were reclassified using legacy and revised RIs. RESULTS: The 2002 RIs were not verified in this contemporary cohort with 24.9% and 5.3% exceeding the historical upper limits for κFLC and κ/λ ratio, respectively. Newly established 99% RIs are 0.61 to 4.02 mg/dL for κ, 0.67 to 3.46 mg/dL for λ, and 0.57 to 2.45 for the κ/λ ratio. Lower estimated glomerular filtration rate (eGFR) was associated with increased FLC concentrations but smaller effects on the κ/λ ratio. Among MASS-FIX negative clinical samples, revised RIs reduced abnormal high flagging for κ/λ ratio from 17.6% to 4.1%. CONCLUSIONS: Legacy FLC RIs do not verify due to assay updates. Nonparametric 99% RIs better reflect contemporary assay performance and substantially reduce clinically meaningful misclassification.
Authors
- Angela A. Dispenzieri (ORCID: https://orcid.org/0000-0001-8780-9512)
- Grant M. Spears (ORCID: https://orcid.org/0000-0001-7781-975X)
- Carin Y. Smith (ORCID: https://orcid.org/0000-0002-3610-6945)
- Stephanie Kalass
- Maria Alice V. Willrich (ORCID: https://orcid.org/0000-0002-9318-7091)
- Erin J. Kaleta
- Michael W. Ettore
- David L. Murray (ORCID: https://orcid.org/0000-0003-1720-335X)
- Jonathan B. Hoyne (ORCID: https://orcid.org/0000-0002-6617-7568)
- Melissa K. Hart
- Jonathan Coker
- Brandon Copet
- Jack L Wu
- Brandon T Copet
- Ashley R Thompson
Institutions
- Mayo Clinic (US)
- Mayo Clinic Health System (US)
- Mayo Clinic in Arizona (US)
- Mayo Clinic in Florida (US)
Publication Details
- Journal
- The Journal of Applied Laboratory Medicine
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1093/jalm/jfag157
- Primary Topic
- Clinical Laboratory Practices and Quality Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00