Re-framing photobiomodulation dosimetry: tissue as a dynamic optical medium

Photobiomodulation dose is conventionally reported as radiant exposure at the tissue surface, in joules per square centimetre. We argue that this descriptor cannot represent the quantity which governs biological effect, and set out what an adequate descriptor is required to contain. Five requirements follow from the physics: the absorbed photon number at the target chromophore under its action spectrum, net of competition from loss chromophores; the distribution of effect through depth, obtained by mapping depth-resolved fluence through a multiphasic response function; the lateral irradiance profile rather than its average, with an explicit convention for beam area; the evolution of the optical properties as tissue heats, perfuses and remodels during exposure; and the stability of the source itself across the exposure. The fourth makes irradiated tissue a self-modifying medium, so the therapeutically relevant dose is a coupled optical, thermal and physiological quantity evaluated over space and time. The class of source and the baseline temperature of the preparation are identified as further variables which a figure in J cm⁻² cannot carry. Reporting practices which would partly meet these requirements now are proposed.

Authors

Publication Details

Published
2026-11-24
DOI
https://doi.org/10.1364/opticaopen.35091292
Primary Topic
Laser Applications in Dentistry and Medicine
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Re-framing photobiomodulation dosimetry: tissue as a dynamic optical medium

Michael Richard Hamblin, Kinga Grzech‐Leśniak, Mark Cronshaw, Steven Parker
2 links
Laser Applications in Dentistry and Medicine
preprint

Re-framing photobiomodulation dosimetry: tissue as a dynamic optical medium

Michael Richard Hamblin, Kinga Grzech‐Leśniak, Mark Cronshaw, Steven Parker
preprint en

Abstract

Photobiomodulation dose is conventionally reported as radiant exposure at the tissue surface, in joules per square centimetre. We argue that this descriptor cannot represent the quantity which governs biological effect, and set out what an adequate descriptor is required to contain. Five requirements follow from the physics: the absorbed photon number at the target chromophore under its action spectrum, net of competition from loss chromophores; the distribution of effect through depth, obtained by mapping depth-resolved fluence through a multiphasic response function; the lateral irradiance profile rather than its average, with an explicit convention for beam area; the evolution of the optical properties as tissue heats, perfuses and remodels during exposure; and the stability of the source itself across the exposure. The fourth makes irradiated tissue a self-modifying medium, so the therapeutically relevant dose is a coupled optical, thermal and physiological quantity evaluated over space and time. The class of source and the baseline temperature of the preparation are identified as further variables which a figure in J cm⁻² cannot carry. Reporting practices which would partly meet these requirements now are proposed.

Good health and well-being
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon