A novel microbeam radiosurgery treatment for intractable seizures utilizing tissue-sparing 25- to 50-μm synchrotron-derived x-rays

OBJECTIVE Approximately one-third of patients with epilepsy meet criteria for drug-resistant epilepsy despite adequate trials of appropriately chosen antiseizure medications. Minimally invasive treatments such as laser interstitial thermal therapy, noninvasive focused ultrasound, and radiosurgical approaches (linear accelerator, Gamma Knife, and proton beam) are treatment options, yet therapeutic effects are delayed by months and often fail to spare normal tissue. Microbeam radiosurgery (MBRS) is a radiosurgical technique using synchrotron-generated x-rays spatially fractionated at the micrometer scale. This narrative review synthesizes > 3 decades of preclinical research on MBRS for epilepsy, examining mechanisms of action, safety profiles, therapeutic efficacy, and the pathway toward clinical translation. METHODS The authors conducted a narrative review of the literature on MBRS from 1992 to 2025, including preclinical studies in rodent epilepsy models, technical development papers, mechanistic investigations, and clinical perspective articles. RESULTS MBRS delivers peak experimental entrance doses of 125–250 Gy (and in some cases up to 600 Gy) through parallel microbeam arrays (width 25–50 µm, spacing 200–400 µm), generating peak-to-valley dose ratios of 20:1 to 50:1, enabling normal tissue sparing while achieving therapeutic effects. In the GAERS (Genetic Absence Epilepsy Rats from Strasbourg) model, MBRS interlaced to the somatosensory cortex achieved quasi-complete suppression of spike-wave discharges for > 4 months without functional deficits. Electrophysiological studies confirmed that irradiated pyramidal neurons retain physiological properties but lose the capacity for pathological synchronization. In kainate-induced temporal lobe epilepsy models, MBRS demonstrated dose-dependent seizure control with optimal efficacy at 125- to 250-Gy peak doses; five-port convergent delivery provided superior therapeutic ratios compared to those of single-port approaches. Cortical and hippocampal transection studies confirmed preservation of eloquent function and the feasibility of deep structure targeting. Histopathological analyses consistently demonstrated tissue preservation in valley regions, with damage confined to microbeam paths, mediated by rapid vascular repair and minimal inflammatory response. CONCLUSIONS MBRS represents a promising, tissue-sparing, noninvasive alternative for focal DRE, deliverable in a single session with rapid irreversible tissue effect. It combines stereotactic precision with spatial fractionation, avoiding the morbidities of invasive surgery. Critical next steps include large animal validation, long-term safety studies exceeding 12 months, compact source development, and phase I clinical trials. The primary limitation remains restricted access, as MBRS requires specialized synchrotron facilities, necessitating patient travel to designated centers.

Authors

Institutions

Publication Details

Journal
Neurosurgical FOCUS
Published
2026-11-25
DOI
https://doi.org/10.3171/2026.9.focus26576
Primary Topic
Epilepsy research and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A novel microbeam radiosurgery treatment for intractable seizures utilizing tissue-sparing 25- to 50-μm synchrotron-derived x-rays

Fred Harden Geisler, Sunil V. Manjila, Jithin Madhusudanan Sreekala
1 links
Neurosurgical FOCUS
Epilepsy research and treatment
article

A novel microbeam radiosurgery treatment for intractable seizures utilizing tissue-sparing 25- to 50-μm synchrotron-derived x-rays

Fred Harden Geisler, Sunil V. Manjila, Jithin Madhusudanan Sreekala
article en

Abstract

OBJECTIVE Approximately one-third of patients with epilepsy meet criteria for drug-resistant epilepsy despite adequate trials of appropriately chosen antiseizure medications. Minimally invasive treatments such as laser interstitial thermal therapy, noninvasive focused ultrasound, and radiosurgical approaches (linear accelerator, Gamma Knife, and proton beam) are treatment options, yet therapeutic effects are delayed by months and often fail to spare normal tissue. Microbeam radiosurgery (MBRS) is a radiosurgical technique using synchrotron-generated x-rays spatially fractionated at the micrometer scale. This narrative review synthesizes > 3 decades of preclinical research on MBRS for epilepsy, examining mechanisms of action, safety profiles, therapeutic efficacy, and the pathway toward clinical translation. METHODS The authors conducted a narrative review of the literature on MBRS from 1992 to 2025, including preclinical studies in rodent epilepsy models, technical development papers, mechanistic investigations, and clinical perspective articles. RESULTS MBRS delivers peak experimental entrance doses of 125–250 Gy (and in some cases up to 600 Gy) through parallel microbeam arrays (width 25–50 µm, spacing 200–400 µm), generating peak-to-valley dose ratios of 20:1 to 50:1, enabling normal tissue sparing while achieving therapeutic effects. In the GAERS (Genetic Absence Epilepsy Rats from Strasbourg) model, MBRS interlaced to the somatosensory cortex achieved quasi-complete suppression of spike-wave discharges for > 4 months without functional deficits. Electrophysiological studies confirmed that irradiated pyramidal neurons retain physiological properties but lose the capacity for pathological synchronization. In kainate-induced temporal lobe epilepsy models, MBRS demonstrated dose-dependent seizure control with optimal efficacy at 125- to 250-Gy peak doses; five-port convergent delivery provided superior therapeutic ratios compared to those of single-port approaches. Cortical and hippocampal transection studies confirmed preservation of eloquent function and the feasibility of deep structure targeting. Histopathological analyses consistently demonstrated tissue preservation in valley regions, with damage confined to microbeam paths, mediated by rapid vascular repair and minimal inflammatory response. CONCLUSIONS MBRS represents a promising, tissue-sparing, noninvasive alternative for focal DRE, deliverable in a single session with rapid irreversible tissue effect. It combines stereotactic precision with spatial fractionation, avoiding the morbidities of invasive surgery. Critical next steps include large animal validation, long-term safety studies exceeding 12 months, compact source development, and phase I clinical trials. The primary limitation remains restricted access, as MBRS requires specialized synchrotron facilities, necessitating patient travel to designated centers.

Neurosurgical FOCUSVol. 61(6)
University of Wisconsin–Madison (US), University of Saskatchewan (CA)
Good health and well-being
Epilepsy research and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon