The endotracheal cuff sealing–perfusion margin depends on mean arterial pressure: an analytical framework with a contact-mechanics test of its premise
Background Endotracheal cuff over-pressure causes tracheal mucosal ischaemia and, in time, stenosis. Practice recommends cuff pressures of 20–30 cmH 2 O, although the threshold at which mucosal perfusion falls is known to scale with systemic blood pressure. We asked what sets the margin between the pressure needed to seal the airway and the pressure at which mucosal perfusion begins to fall. Methods For a cuff that conforms to the tracheal wall, contact pressure equals cuff pressure, so the margin follows in closed form from literature-derived perfusion-to-MAP ratios and clinical sealing pressures; we propagated the uncertainty of these inputs by variance-based sensitivity analysis. A two-dimensional, finite-strain contact model of a D-shaped trachea (neo-Hookean cartilage, Holzapfel–Gasser–Ogden membranous wall) was used to examine the premise of that result, contrasting a conforming cuff with an over-distended cuff that forces the lumen circular. Results We assumed that perfusion begins to fall within the range of contact-pressure/MAP ratios at which marked flow reduction has been observed (0.20–0.30). Under this assumption the margin became negative below a critical MAP equal to the sealing pressure divided by the onset ratio, spanning 49–110 mmHg across that range and a sealing pressure of 20–30 cmH 2 O (59–88 mmHg at the mid-range ratio); an earlier true onset would raise it. Below it, no cuff pressure both seals and avoids some reduction of mucosal perfusion. MAP and the sealing pressure dominated the output variance. The assumed onset pressure at MAP 75 mmHg (20.4–30.6 cmH 2 O) overlapped an independent empirical injury-prevention estimate (95% CI 19.27–29.37 cmH 2 O). When the cuff no longer conformed, contact pressure became strongly non-uniform and was governed by tissue geometry, chiefly the cartilage fraction, rather than by the cuff-pressure reading. Conclusions At low MAP a fixed 30 cmH 2 O ceiling can exceed the pressure at which mucosal perfusion is assumed to begin to fall, and even the minimum effective sealing pressure may do so. The critical MAP is a band rather than a patient-level cut-off. Whether cuff management should be individualised against blood pressure is a hypothesis that requires prospective testing against mucosal injury and stenosis outcomes.
Authors
- Ming-Yu Hsieh (ORCID: https://orcid.org/0000-0002-5797-3474)
Institutions
- Chung Shan Medical University Hospital (TW)
- Chung Shan Medical University (TW)
Publication Details
- Journal
- Frontiers in Medicine
- Published
- 2026-11-24
- DOI
- https://doi.org/10.3389/fmed.2026.2009235
- Primary Topic
- Airway Management and Intubation Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00