Power quality is an important consideration in solar–battery–motor–flywheel systems, as variations in alternator terminal voltage and waveform distortion may affect electrical performance. Evaluating the voltage characteristics of single-phase and three-phase alternators under different operating conditions is essential for understanding their power-quality behaviour and suitability for practical applications. This study characterises the output-voltage quality of two 10 kVA STC-type synchronous alternators operated separately in a photovoltaic–battery–electric-motor–flywheel arrangement. A 34 kg flywheel and a 2.2 kW drive motor were incorporated into the test assembly. Voltage waveforms, rotational speeds and selected electrical powers were documented using an oscilloscope, a tachometer and electrical meters. During 12 observations at five-minute intervals, the single-phase alternator delivered a mean no-load voltage of 239.50 V at recorded mean flywheel and alternator speeds of 1,485.58 and 1,526.08 rpm, respectively. The single-phase waveform was visibly distorted relative to the observed utility waveform. Using the reported harmonic amplitudes of 35, 28 and 18 V and an assumed RMS convention, the corresponding three-component voltage THD estimate is 20.59%. For the three-phase test, the 12 operating observations gave mean phase and line voltages of 476.92 and 786.85 V, with a recorded mean rotational speed of 2,672.25 rpm. During a separate 3 kW load trial, the reported phase and line voltages were 236 and 410 V. The observations identify output-voltage distortion and substantial differences between unloaded and loaded voltages. They also motivate improved excitation regulation, load-specific power-quality assessment and synchronised electrical–mechanical monitoring for this class of generator arrangement.

Authors

Institutions

Publication Details

Journal
Journal of Energy Research and Reviews
Published
2026-11-24
DOI
https://doi.org/10.9734/jenrr/2026/v18i12557
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Power Quality of Single-Phase and Three-Phase 10 kVA STC Alternators in a Solar–Battery–Motor–Flywheel System

KAM Sié, YE Siédouba Georges, ZONGO Lamoussa Bernard
1 links
Journal of Energy Research and Reviews
Power Quality and Harmonics
article

Power Quality of Single-Phase and Three-Phase 10 kVA STC Alternators in a Solar–Battery–Motor–Flywheel System

KAM Sié, YE Siédouba Georges, ZONGO Lamoussa Bernard
article en

Abstract

Power quality is an important consideration in solar–battery–motor–flywheel systems, as variations in alternator terminal voltage and waveform distortion may affect electrical performance. Evaluating the voltage characteristics of single-phase and three-phase alternators under different operating conditions is essential for understanding their power-quality behaviour and suitability for practical applications. This study characterises the output-voltage quality of two 10 kVA STC-type synchronous alternators operated separately in a photovoltaic–battery–electric-motor–flywheel arrangement. A 34 kg flywheel and a 2.2 kW drive motor were incorporated into the test assembly. Voltage waveforms, rotational speeds and selected electrical powers were documented using an oscilloscope, a tachometer and electrical meters. During 12 observations at five-minute intervals, the single-phase alternator delivered a mean no-load voltage of 239.50 V at recorded mean flywheel and alternator speeds of 1,485.58 and 1,526.08 rpm, respectively. The single-phase waveform was visibly distorted relative to the observed utility waveform. Using the reported harmonic amplitudes of 35, 28 and 18 V and an assumed RMS convention, the corresponding three-component voltage THD estimate is 20.59%. For the three-phase test, the 12 operating observations gave mean phase and line voltages of 476.92 and 786.85 V, with a recorded mean rotational speed of 2,672.25 rpm. During a separate 3 kW load trial, the reported phase and line voltages were 236 and 410 V. The observations identify output-voltage distortion and substantial differences between unloaded and loaded voltages. They also motivate improved excitation regulation, load-specific power-quality assessment and synchronised electrical–mechanical monitoring for this class of generator arrangement.

Journal of Energy Research and ReviewsVol. 18(12)
Université Joseph Ki-Zerbo (BF), Centre National de la Recherche Scientifique et Technologique (BF)
Affordable and clean energy
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Power Quality of Single-Phase and Three-Phase 10 kVA STC Alternators in a Solar–Battery–Motor–Flywheel System — KAM Sié, YE Siédouba Georges, et al. · Journal of Energy Research and Reviews (2026) | TGRS Research Map | TGRS