Design and Preliminary Characterization of an IoT-Enabled Multi-Sensor Monitoring and Control System for a Dual-Temperature Laboratory-Scale Biogas Fermenter

This paper presents the design, implementation, and preliminary experimental characterization of an IoT-enabled multi-sensor monitoring and control system integrated into a laboratory-scale biogas fermenter designed for dual-temperature operation (mesophilic: 35–40 °C; thermophilic: 50–60 °C). The platform acquires, time-aligns, and displays data streams from temperature (DS18B20), ultrasonic liquid-level (HC-SR04), and semiconductor gas (MQ2/MQ135) sensors within a distributed Master–Slave sensing and control architecture (ESP32/Arduino) and closes a PID temperature loop. The PID loop was tuned from experimentally identified first-order-plus-dead-time (FOPDT) process dynamics (Kr = 0.98 °C/%, L = 122 s, Tp = 5977 s). Closed-loop tests were performed with water as a thermal simulant at a single 37 °C setpoint (mesophilic range); thermophilic setpoints were not tested. After retuning from the Chien–Hrones–Reswick (CHR) values (KP = 28, KI = 0.005, KD = 350), the overshoot decreased from 2.9 °C to ≈0.6 °C and the DS18B20 reading settled within ±0.1 °C of the setpoint (setpoint-holding stability; the specified sensor accuracy is ±0.5 °C). A non-invasive ultrasonic communicating-vessels subsystem was tested with compressed air as a gas-volume surrogate, with a 10 mL volume-display resolution, while a cloud telemetry layer (15 s reporting interval) presents the multi-sensor data on a common time axis for remote monitoring and data export. The results demonstrate the operation of the hardware, control, and telemetry chain. The platform provides a basis for future validation and for systematic comparison of mesophilic versus thermophilic anaerobic digestion in laboratory-scale bioprocess monitoring.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-24
DOI
https://doi.org/10.3390/app162311635
Primary Topic
Arduino and IoT Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design and Preliminary Characterization of an IoT-Enabled Multi-Sensor Monitoring and Control System for a Dual-Temperature Laboratory-Scale Biogas Fermenter

Gabriela Cristina Ionescu, Cristina Roxana Popa, Marian Ion, B. Nicolae Musat
1 links
Applied Sciences
Arduino and IoT Applications
article

Design and Preliminary Characterization of an IoT-Enabled Multi-Sensor Monitoring and Control System for a Dual-Temperature Laboratory-Scale Biogas Fermenter

Gabriela Cristina Ionescu, Cristina Roxana Popa, Marian Ion, B. Nicolae Musat
article en

Abstract

This paper presents the design, implementation, and preliminary experimental characterization of an IoT-enabled multi-sensor monitoring and control system integrated into a laboratory-scale biogas fermenter designed for dual-temperature operation (mesophilic: 35–40 °C; thermophilic: 50–60 °C). The platform acquires, time-aligns, and displays data streams from temperature (DS18B20), ultrasonic liquid-level (HC-SR04), and semiconductor gas (MQ2/MQ135) sensors within a distributed Master–Slave sensing and control architecture (ESP32/Arduino) and closes a PID temperature loop. The PID loop was tuned from experimentally identified first-order-plus-dead-time (FOPDT) process dynamics (Kr = 0.98 °C/%, L = 122 s, Tp = 5977 s). Closed-loop tests were performed with water as a thermal simulant at a single 37 °C setpoint (mesophilic range); thermophilic setpoints were not tested. After retuning from the Chien–Hrones–Reswick (CHR) values (KP = 28, KI = 0.005, KD = 350), the overshoot decreased from 2.9 °C to ≈0.6 °C and the DS18B20 reading settled within ±0.1 °C of the setpoint (setpoint-holding stability; the specified sensor accuracy is ±0.5 °C). A non-invasive ultrasonic communicating-vessels subsystem was tested with compressed air as a gas-volume surrogate, with a 10 mL volume-display resolution, while a cloud telemetry layer (15 s reporting interval) presents the multi-sensor data on a common time axis for remote monitoring and data export. The results demonstrate the operation of the hardware, control, and telemetry chain. The platform provides a basis for future validation and for systematic comparison of mesophilic versus thermophilic anaerobic digestion in laboratory-scale bioprocess monitoring.

Applied SciencesVol. 16(23)
Petroleum & Gas University of Ploieşti (RO), National Institute for Research and Development in Microtechnologies (RO)
European Regional Development Fund
Industry, innovation and infrastructure, Affordable and clean energy
Arduino and IoT Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon