COMPARATIVE EVALUATION OF INTRAOCULAR PRESSURE DYNAMICS FOLLOWING STEROID INDUCTION AND EPISCLERAL VEIN CAUTERIZATION FOR ESTABLISHING RABBIT MODELS OF GLAUCOMA: A PRE-EXPERIMENTAL STUDY

Background: Experimental animal models are essential for understanding glaucoma pathophysiology and evaluating potential therapeutic interventions. Rabbits are commonly used in glaucoma research because of their anatomical similarities to the human eye and their relatively low maintenance cost. However, the comparative effectiveness of different glaucoma induction methods in rabbits remains insufficiently explored. Objective: To compare the effectiveness of steroid administration and episcleral vein cauterization methods in inducing experimental glaucoma in rabbit models based on intraocular pressure (IOP) elevation. Methods: This preliminary experimental study involved eight male New Zealand rabbits divided into four intervention groups: topical steroid eye drops, subconjunctival steroid injection, three-vein episcleral cauterization, and four-vein episcleral cauterization. IOP measurements were obtained daily for one month using iCare and TonoVet tonometers. Comparative analyses were performed to evaluate the magnitude and duration of IOP elevation among groups. Results: Steroid-induced models demonstrated higher and more sustained IOP elevation compared with episcleral vein cauterization methods. The mean IOP values were 20.45 mmHg in the topical steroid group, 19.98 mmHg in the subconjunctival steroid group, 19.45 mmHg in the four-vein cauterization group, and 16.69 mmHg in the threevein cauterization group. Episcleral vein cauterization produced only transient IOP elevation lasting approximately 24 hours. Conclusion: Steroid-based methods, particularly topical steroid administration, were more effective in producing stable and sustained IOP elevation in rabbit glaucoma models than episcleral vein cauterization techniques.

Authors

Institutions

Publication Details

Journal
International Journal of Drug Delivery Technology
Published
2026-11-24
DOI
https://doi.org/10.25258/ijddt.16.80s.229
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

COMPARATIVE EVALUATION OF INTRAOCULAR PRESSURE DYNAMICS FOLLOWING STEROID INDUCTION AND EPISCLERAL VEIN CAUTERIZATION FOR ESTABLISHING RABBIT MODELS OF GLAUCOMA: A PRE-EXPERIMENTAL STUDY

Andi Muhammad Ichsan, Ririn Nislawati, Itzar Chaidir Islam, Noro Waspodo et al.
International Journal of Drug Delivery Technology
Glaucoma and retinal disorders
article

COMPARATIVE EVALUATION OF INTRAOCULAR PRESSURE DYNAMICS FOLLOWING STEROID INDUCTION AND EPISCLERAL VEIN CAUTERIZATION FOR ESTABLISHING RABBIT MODELS OF GLAUCOMA: A PRE-EXPERIMENTAL STUDY

Andi Muhammad Ichsan, Ririn Nislawati, Itzar Chaidir Islam, Noro Waspodo, Arief Abdurrazaq Dharma
article en

Abstract

Background: Experimental animal models are essential for understanding glaucoma pathophysiology and evaluating potential therapeutic interventions. Rabbits are commonly used in glaucoma research because of their anatomical similarities to the human eye and their relatively low maintenance cost. However, the comparative effectiveness of different glaucoma induction methods in rabbits remains insufficiently explored. Objective: To compare the effectiveness of steroid administration and episcleral vein cauterization methods in inducing experimental glaucoma in rabbit models based on intraocular pressure (IOP) elevation. Methods: This preliminary experimental study involved eight male New Zealand rabbits divided into four intervention groups: topical steroid eye drops, subconjunctival steroid injection, three-vein episcleral cauterization, and four-vein episcleral cauterization. IOP measurements were obtained daily for one month using iCare and TonoVet tonometers. Comparative analyses were performed to evaluate the magnitude and duration of IOP elevation among groups. Results: Steroid-induced models demonstrated higher and more sustained IOP elevation compared with episcleral vein cauterization methods. The mean IOP values were 20.45 mmHg in the topical steroid group, 19.98 mmHg in the subconjunctival steroid group, 19.45 mmHg in the four-vein cauterization group, and 16.69 mmHg in the threevein cauterization group. Episcleral vein cauterization produced only transient IOP elevation lasting approximately 24 hours. Conclusion: Steroid-based methods, particularly topical steroid administration, were more effective in producing stable and sustained IOP elevation in rabbit glaucoma models than episcleral vein cauterization techniques.

International Journal of Drug Delivery TechnologyVol. 16(80s)
Hasanuddin University (ID)
Universitas Hasanuddin
Good health and well-being
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon