Thirty Minute Ahead Risk Modeling of CGM Derived Personalized Glycemic Excursions from Food Log, Contextual, and Wearable Features: A Participant Level Evaluation

Continuous glucose monitoring (CGM) characterizes glycemic variability, but whether food log, contextual, and wrist sensor information can indicate a future participant relative excursion remains uncertain. We performed a retrospective feasibility analysis of the public PhysioNet BIG IDEAs Lab dataset: 16 participants with Dexcom G6 CGM, Empatica E4 streams, food logs, and demographic variables. PersLow, PersNorm, and PersHigh outcomes were defined from each participant's prior 24 hour CGM distribution; CGM was excluded from model predictors. Targets were matched at the exact clock time 30 minutes after prediction, and evaluation used leave-one-participant out folds with participant level uncertainty. The revised 87 variable full multimodal LightGBM model achieved mean participant macro F1 0.462 (95% bootstrap CI 0.424-0.499; median 0.488, IQR 0.410-0.518). A 39 variable food/context comparator achieved 0.443 (95% CI 0.409-0.476); the paired full-minus-comparator difference was +0.020 (95% CI 0.009-0.033). Removing explicit sensor missingness variables left predictions unchanged, and removing broader coverage proxies produced macro F1 0.465. A separate retrospective random-forest calibration analysis using personal CGM labels yielded common window macro F1 of 0.380 at 0 hours and 0.431 at 72 hours; this does not establish prospective personalization effectiveness. Most PersLow and PersHigh targets did not cross clinical glucose thresholds, and corrected event analyses retained nontrivial false alarm rates. The confidence intervals quantify participant variation conditional on the fitted analyses and do not account for the extensive model development and selection process. The small observed internal difference does not establish a clinically meaningful or externally generalizable wearable benefit. These exploratory findings do not establish glucose measurement, diagnosis, CGM free initialization, or prospective alerting.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-11-24
DOI
https://doi.org/10.1088/1873-4030/aec5fa
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Thirty Minute Ahead Risk Modeling of CGM Derived Personalized Glycemic Excursions from Food Log, Contextual, and Wearable Features: A Participant Level Evaluation

Turker Berk Donmez, Mohammed Mansour
1 links
Medical Engineering & Physics
Diabetes Management and Research
article

Thirty Minute Ahead Risk Modeling of CGM Derived Personalized Glycemic Excursions from Food Log, Contextual, and Wearable Features: A Participant Level Evaluation

Turker Berk Donmez, Mohammed Mansour
article en

Abstract

Continuous glucose monitoring (CGM) characterizes glycemic variability, but whether food log, contextual, and wrist sensor information can indicate a future participant relative excursion remains uncertain. We performed a retrospective feasibility analysis of the public PhysioNet BIG IDEAs Lab dataset: 16 participants with Dexcom G6 CGM, Empatica E4 streams, food logs, and demographic variables. PersLow, PersNorm, and PersHigh outcomes were defined from each participant's prior 24 hour CGM distribution; CGM was excluded from model predictors. Targets were matched at the exact clock time 30 minutes after prediction, and evaluation used leave-one-participant out folds with participant level uncertainty. The revised 87 variable full multimodal LightGBM model achieved mean participant macro F1 0.462 (95% bootstrap CI 0.424-0.499; median 0.488, IQR 0.410-0.518). A 39 variable food/context comparator achieved 0.443 (95% CI 0.409-0.476); the paired full-minus-comparator difference was +0.020 (95% CI 0.009-0.033). Removing explicit sensor missingness variables left predictions unchanged, and removing broader coverage proxies produced macro F1 0.465. A separate retrospective random-forest calibration analysis using personal CGM labels yielded common window macro F1 of 0.380 at 0 hours and 0.431 at 72 hours; this does not establish prospective personalization effectiveness. Most PersLow and PersHigh targets did not cross clinical glucose thresholds, and corrected event analyses retained nontrivial false alarm rates. The confidence intervals quantify participant variation conditional on the fitted analyses and do not account for the extensive model development and selection process. The small observed internal difference does not establish a clinically meaningful or externally generalizable wearable benefit. These exploratory findings do not establish glucose measurement, diagnosis, CGM free initialization, or prospective alerting.

Medical Engineering & Physics
Sakarya University (TR), Sakarya Uygulamalı Bilimler Üniversitesi (TR)
Sakarya Üniversitesi
Good health and well-being
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon