An automated computer vision framework for the systematic sizing and kinematic analysis of multiple droplets in ultra-high-speed videos

Measuring the size and motion of individual droplets in sprays remains challenging when many droplets coexist, overlap, or cross paths in ultra-high-speed recordings. We present Droplet Analyzer (DA), an automated open-source framework built on OpenCV that combines droplet detection, geometric characterization, trajectory reconstruction, and two-dimensional velocity estimation, and preserves the link between size, position, and velocity for each droplet. Performance was quantified with synthetic sequences with prescribed droplet sizes, positions, and velocities, processed with a configuration selected on an independent tuning set. Droplets of 4 pixels (px) and larger were detected under moderate noise, relative sizing errors were below 10 % for diameters of at least 15 px, and velocity errors for isolated droplets remained below 2.4 % for displacements of about 1.5 px per frame or more. Increasing scene density mainly degraded trajectory continuity. For a published Flow Blurring condition, DA median diameters (36.6–40.7 µm) were within 1–2 px of those obtained with an earlier image-analysis method and of the same order as laser-diffraction measurements. DA was then applied to electrically assisted Flow Blurring sprays from injectors with 700 and 900 µm orifices at seven voltages between 0 and 12 kV, using 3208 trajectories from 50 recordings. At 12 kV, the volume median diameter decreased by 62 % and 36 % for the 700 and 900 µm injectors, respectively, and local volume median diameters decreased in all sampled transverse regions, whereas the number median remained nearly constant and the 90th percentile of the diameter decreased. Droplet velocity decreased with increasing diameter and showed no systematic dependence on voltage. Trajectory-resolved imaging thus separates changes in the larger droplets from those in the bulk population and resolves how the size distribution varies across the spray. These droplet-level data are relevant to aerosol generation and to the subsequent transport and deposition of the droplets.

Authors

Institutions

Publication Details

Published
2026-11-24
DOI
https://doi.org/10.5194/ar-2026-52
Primary Topic
Fluid Dynamics and Heat Transfer
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

An automated computer vision framework for the systematic sizing and kinematic analysis of multiple droplets in ultra-high-speed videos

Manuel Carranza-García, Luis B. Modesto-López, Carlos Pérez-Cantalapiedra
Fluid Dynamics and Heat Transfer
preprint

An automated computer vision framework for the systematic sizing and kinematic analysis of multiple droplets in ultra-high-speed videos

Manuel Carranza-García, Luis B. Modesto-López, Carlos Pérez-Cantalapiedra
preprint en

Abstract

Measuring the size and motion of individual droplets in sprays remains challenging when many droplets coexist, overlap, or cross paths in ultra-high-speed recordings. We present Droplet Analyzer (DA), an automated open-source framework built on OpenCV that combines droplet detection, geometric characterization, trajectory reconstruction, and two-dimensional velocity estimation, and preserves the link between size, position, and velocity for each droplet. Performance was quantified with synthetic sequences with prescribed droplet sizes, positions, and velocities, processed with a configuration selected on an independent tuning set. Droplets of 4 pixels (px) and larger were detected under moderate noise, relative sizing errors were below 10 % for diameters of at least 15 px, and velocity errors for isolated droplets remained below 2.4 % for displacements of about 1.5 px per frame or more. Increasing scene density mainly degraded trajectory continuity. For a published Flow Blurring condition, DA median diameters (36.6–40.7 µm) were within 1–2 px of those obtained with an earlier image-analysis method and of the same order as laser-diffraction measurements. DA was then applied to electrically assisted Flow Blurring sprays from injectors with 700 and 900 µm orifices at seven voltages between 0 and 12 kV, using 3208 trajectories from 50 recordings. At 12 kV, the volume median diameter decreased by 62 % and 36 % for the 700 and 900 µm injectors, respectively, and local volume median diameters decreased in all sampled transverse regions, whereas the number median remained nearly constant and the 90th percentile of the diameter decreased. Droplet velocity decreased with increasing diameter and showed no systematic dependence on voltage. Trajectory-resolved imaging thus separates changes in the larger droplets from those in the bulk population and resolves how the size distribution varies across the spray. These droplet-level data are relevant to aerosol generation and to the subsequent transport and deposition of the droplets.

Instituto de Recursos Naturales y Agrobiología de Sevilla (ES), Universidad de Sevilla (ES)
Agencia Estatal de Investigación
Fluid Dynamics and Heat Transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon