Proof-of-Concept Evaluation of a Hybrid Qualitative-Quantitative LC-HRMS Workflow for Nitrosamine Determination in Tomatoes and Cucumbers

Nitrosamine determination in food matrices requires both sensitive quantitative measurement and sufficient qualitative evidence to distinguish analytes from matrix-related interferences. This proof-of-concept study evaluated a hybrid liquid chromatography-high-resolution mass spectrometry (LC-HRMS) workflow for complementary quantitative determination and qualitative confirmation of nitrosamines in tomato and cucumber as representative high-moisture fresh-produce matrices. Samples were extracted using a QuEChERS-based procedure and analyzed using a UHPLC system coupled to an Orbitrap mass spectrometer with full-scan and data-dependent MS2 (ddMS2) acquisition. Sixteen nitrosamines were included in the quantitative proof-of-concept evaluation. For these analytes, neat-standard calibration produced coefficients of determination (R2) above 0.98, injection repeatability at 10 ng/mL showed relative standard deviation (RSD) values of 2–18% and estimated limits of quantification (LOQs) based on signal-to-noise ratios ≥10 were 1–5 ng/mL. Apparent response recovery, calculated by comparison of pre-extraction spiked samples with neat standards, ranged approximately from 83% to 126% for the 16-analyte set because post-extraction spikes and matrix-matched calibration were not included. These values represent combined extraction and matrix-response effects rather than isolated extraction recovery. Qualitative processing used Compound Discoverer with accurate-mass filtering, retention-time information, a user-defined mass list, mzCloud and ChemSpider. Automated annotation was supplemented by manual structural review where required, including N-nitrosopiperidine (NPIP), for which an alternative same-formula ChemSpider candidate was initially returned. No target nitrosamines were detected in the unspiked tomato and cucumber samples analyzed. The study demonstrates the feasibility of using a single HRMS data set to support targeted quantitative evaluation together with confirmatory qualitative interpretation while preserving data for potential retrospective interrogation. Broader matrix applicability and routine quantitative use would require matrix-specific validation.

Authors

Publication Details

Journal
Figshare
Published
2026-11-24
DOI
https://doi.org/10.6084/m9.figshare.35106844
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Proof-of-Concept Evaluation of a Hybrid Qualitative-Quantitative LC-HRMS Workflow for Nitrosamine Determination in Tomatoes and Cucumbers

Jyoti Rawat, Varun Khali
2 links
Figshare
Pesticide Residue Analysis and Safety
article

Proof-of-Concept Evaluation of a Hybrid Qualitative-Quantitative LC-HRMS Workflow for Nitrosamine Determination in Tomatoes and Cucumbers

Jyoti Rawat, Varun Khali
article en

Abstract

Nitrosamine determination in food matrices requires both sensitive quantitative measurement and sufficient qualitative evidence to distinguish analytes from matrix-related interferences. This proof-of-concept study evaluated a hybrid liquid chromatography-high-resolution mass spectrometry (LC-HRMS) workflow for complementary quantitative determination and qualitative confirmation of nitrosamines in tomato and cucumber as representative high-moisture fresh-produce matrices. Samples were extracted using a QuEChERS-based procedure and analyzed using a UHPLC system coupled to an Orbitrap mass spectrometer with full-scan and data-dependent MS2 (ddMS2) acquisition. Sixteen nitrosamines were included in the quantitative proof-of-concept evaluation. For these analytes, neat-standard calibration produced coefficients of determination (R2) above 0.98, injection repeatability at 10 ng/mL showed relative standard deviation (RSD) values of 2–18% and estimated limits of quantification (LOQs) based on signal-to-noise ratios ≥10 were 1–5 ng/mL. Apparent response recovery, calculated by comparison of pre-extraction spiked samples with neat standards, ranged approximately from 83% to 126% for the 16-analyte set because post-extraction spikes and matrix-matched calibration were not included. These values represent combined extraction and matrix-response effects rather than isolated extraction recovery. Qualitative processing used Compound Discoverer with accurate-mass filtering, retention-time information, a user-defined mass list, mzCloud and ChemSpider. Automated annotation was supplemented by manual structural review where required, including N-nitrosopiperidine (NPIP), for which an alternative same-formula ChemSpider candidate was initially returned. No target nitrosamines were detected in the unspiked tomato and cucumber samples analyzed. The study demonstrates the feasibility of using a single HRMS data set to support targeted quantitative evaluation together with confirmatory qualitative interpretation while preserving data for potential retrospective interrogation. Broader matrix applicability and routine quantitative use would require matrix-specific validation.

Figshare
Zero hunger
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon