Feasibility of an Intermittently Powered Bioelectronic Sensing System for Smart Knee Implants: A Coupled Electromagnetic–Thermal–Circuit Simulation Study

Smart knee implants can provide objective functional information during postoperative follow-up, but long-term autonomous monitoring requires an implanted energy source capable of supporting sensing, processing, and wireless communication over extended periods. This study investigates an alternative architecture based on intermittent, physician-supervised operation, in which energy is transferred wirelessly immediately before a predefined measurement session. A 150 kHz inductive wireless power-transfer system was modeled in COMSOL Multiphysics to quantify the electrical output of an implanted receiver and evaluate electromagnetic losses and associated thermal effects in the receiver assembly, metallic tibial implant, bone, and surrounding soft tissue. The COMSOL-derived receiver port was subsequently reduced to a Thévenin equivalent and incorporated into an LTspice model comprising rectification, DC filtering, supercapacitor charging, regulated power delivery, and representative low-power implant electronics. The simulations showed that the received energy was sufficient to charge an 8 F, 2.7 V electric double-layer capacitor and subsequently maintain the modeled 3.0 V electronic supply for approximately 19.8 min after removal of the external power source. For the Main+Aux configuration, the maximum simulated temperature rise remained below 1 °C during 600 s of continuous excitation with a fixed 220 Ω receiver load. This thermal exposure was evaluated separately from the EDLC charging transient. All reported results for wireless power transfer, temperature rise, and post-charging operating time are based solely on simulations. These predictions support further evaluation of the proposed intermittent operating concept through prototype testing, including verification of electrical and thermal performance and assessment of mechanical integration, biocompatibility, and MR safety. The present simulation framework therefore provides a quantitative basis for subsequent prototype development and experimental validation, while identifying the electrical, thermal, and energy-storage conditions that should be verified in future studies.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-11-24
DOI
https://doi.org/10.3390/bios16120685
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Feasibility of an Intermittently Powered Bioelectronic Sensing System for Smart Knee Implants: A Coupled Electromagnetic–Thermal–Circuit Simulation Study

Oana Roxana Oprea, Ildiko Peter, Dana Rus, Dorin Bică et al.
1 links
Biosensors
Wireless Power Transfer Systems
article

Feasibility of an Intermittently Powered Bioelectronic Sensing System for Smart Knee Implants: A Coupled Electromagnetic–Thermal–Circuit Simulation Study

Oana Roxana Oprea, Ildiko Peter, Dana Rus, Dorin Bică, Radu Ilinca, Albert Zsolt Barabas, Magdalena Miana Radu
article en

Abstract

Smart knee implants can provide objective functional information during postoperative follow-up, but long-term autonomous monitoring requires an implanted energy source capable of supporting sensing, processing, and wireless communication over extended periods. This study investigates an alternative architecture based on intermittent, physician-supervised operation, in which energy is transferred wirelessly immediately before a predefined measurement session. A 150 kHz inductive wireless power-transfer system was modeled in COMSOL Multiphysics to quantify the electrical output of an implanted receiver and evaluate electromagnetic losses and associated thermal effects in the receiver assembly, metallic tibial implant, bone, and surrounding soft tissue. The COMSOL-derived receiver port was subsequently reduced to a Thévenin equivalent and incorporated into an LTspice model comprising rectification, DC filtering, supercapacitor charging, regulated power delivery, and representative low-power implant electronics. The simulations showed that the received energy was sufficient to charge an 8 F, 2.7 V electric double-layer capacitor and subsequently maintain the modeled 3.0 V electronic supply for approximately 19.8 min after removal of the external power source. For the Main+Aux configuration, the maximum simulated temperature rise remained below 1 °C during 600 s of continuous excitation with a fixed 220 Ω receiver load. This thermal exposure was evaluated separately from the EDLC charging transient. All reported results for wireless power transfer, temperature rise, and post-charging operating time are based solely on simulations. These predictions support further evaluation of the proposed intermittent operating concept through prototype testing, including verification of electrical and thermal performance and assessment of mechanical integration, biocompatibility, and MR safety. The present simulation framework therefore provides a quantitative basis for subsequent prototype development and experimental validation, while identifying the electrical, thermal, and energy-storage conditions that should be verified in future studies.

BiosensorsVol. 16(12)
Carol Davila University of Medicine and Pharmacy (RO), Universitatea de Medicină, Farmacie, Științe și Tehnologie „George Emil Palade” din Târgu Mureș (RO)
European Commission
Good health and well-being
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon