Cross-State Transfer and Threshold Calibration of a Multi-Source Near-Real-Time Municipal Fire-Alert Framework in Northeastern Brazil

Municipal hotspot-alert thresholds tuned in one Brazilian state often fail when copied to neighbors with denser dry-season fire regimes. We do not propose a new fire detector or a burned-area map. We evaluate a deployment protocol for transferring municipality-day three-class hotspot alerts (NO/UNCERTAIN/YES) from Ceará to Maranhão, Piauí, and Tocantins (Cerrado), and for calibrating the YES threshold τ under domain shift. The prediction target is next-day municipal hotspot activity derived from INPE BDQueimadas—not confirmed incidents, suppression demand, or MapBiomas burned area. Experiments EXP-TRANSFER-001/002 use chronological 70/10/20 date splits and XGBoost on INPE-native or Open-Meteo+biome features (single dry season 2025; 15 municipalities per state). On the Ceará holdout (n=555 municipality-days; YES prevalence 81.1%), the INPE-native model at τ=0.30 reaches 84.8% YES precision (95% CI [81.6, 87.7]) and 91.6% recall. Zero-shot precision falls to 59.5% (MA), 58.8% (PI), and 35.7% (TO) as YES prevalence drops to ≈38% and 16%. State-specific τ* chosen on each target calibration slice (not on the test set; not on Ceará alone) recovers precision to 76.4% (MA), 68.6% (PI), and 44.4% (TO). That recovery is a deliberate precision–recall trade-off: on Maranhão, CE+τ* cuts false YES from 142 to 38 but raises missed YES from 4 to 90. EXP-TRANSFER-003 shows CE+τ* can exceed target-trained precision on MA/PI under the same temporal rules, while a fire-count baseline still leads on Tocantins precision (45.9%). EXP-TRANSFER-004 attributes the TO failure to joint prevalence and feature shift (YES 16%; SMD drought/fire_t ≈ 0.8). EXP-TRANSFER-005 shows that dropping same-day fire_t leaves calibrated MA/PI precision nearly unchanged (76.4%→73.4%; 68.6%→66.5%), so the transfer finding is not a same-day label reconstruction artifact. EXP-TRANSFER-006/007 replicate CE+τ* across dry seasons 2023–2025 with significant bootstrap ΔP on MA/PI, leave-one-municipality-out precision 0.88±0.08 on Ceará, and a top-30 sensitivity check. EXP-TRANSFER-010 shows Maranhão CE+τ* precision holds on 212 municipalities (near-statewide). EXP-TRANSFER-008/009 corroborate municipal hotspot activity with MapBiomas Fire Collection 5: annual burned area vs focos Spearman ρ=0.93 (n=120), and month-resolved GeoTIFF burned area vs focos ρ=0.84 (n=720 mun×month; 99.7% of BA-positive months have INPE focos). The protocol is useful as a low-false-alarm operating point where agencies accept lower recall (MA/PI) and flags where local rules remain preferable (TO under low prevalence). Findings concern hotspot-based municipal prioritization—not daily burned-area mapping. This is a preprint submitted to Remote Sensing Applications: Society and Environment (RSASE). It has not been peer reviewed. The record is an unpublished draft.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-24
DOI
https://doi.org/10.5281/zenodo.24516566
Primary Topic
Fire effects on ecosystems
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Cross-State Transfer and Threshold Calibration of a Multi-Source Near-Real-Time Municipal Fire-Alert Framework in Northeastern Brazil

Adriano Bessa Albuquerque, João Alexandre Lôbo Marques, Francisco Nauber Bernardo Gois, Vladia Celia Monteiro Pinheiro et al.
3 links
Zenodo (CERN European Organization for Nuclear Research)
Fire effects on ecosystems
preprint

Cross-State Transfer and Threshold Calibration of a Multi-Source Near-Real-Time Municipal Fire-Alert Framework in Northeastern Brazil

Adriano Bessa Albuquerque, João Alexandre Lôbo Marques, Francisco Nauber Bernardo Gois, Vladia Celia Monteiro Pinheiro, Daniel Macedo
preprint en

Abstract

Municipal hotspot-alert thresholds tuned in one Brazilian state often fail when copied to neighbors with denser dry-season fire regimes. We do not propose a new fire detector or a burned-area map. We evaluate a deployment protocol for transferring municipality-day three-class hotspot alerts (NO/UNCERTAIN/YES) from Ceará to Maranhão, Piauí, and Tocantins (Cerrado), and for calibrating the YES threshold τ under domain shift. The prediction target is next-day municipal hotspot activity derived from INPE BDQueimadas—not confirmed incidents, suppression demand, or MapBiomas burned area. Experiments EXP-TRANSFER-001/002 use chronological 70/10/20 date splits and XGBoost on INPE-native or Open-Meteo+biome features (single dry season 2025; 15 municipalities per state). On the Ceará holdout (n=555 municipality-days; YES prevalence 81.1%), the INPE-native model at τ=0.30 reaches 84.8% YES precision (95% CI [81.6, 87.7]) and 91.6% recall. Zero-shot precision falls to 59.5% (MA), 58.8% (PI), and 35.7% (TO) as YES prevalence drops to ≈38% and 16%. State-specific τ* chosen on each target calibration slice (not on the test set; not on Ceará alone) recovers precision to 76.4% (MA), 68.6% (PI), and 44.4% (TO). That recovery is a deliberate precision–recall trade-off: on Maranhão, CE+τ* cuts false YES from 142 to 38 but raises missed YES from 4 to 90. EXP-TRANSFER-003 shows CE+τ* can exceed target-trained precision on MA/PI under the same temporal rules, while a fire-count baseline still leads on Tocantins precision (45.9%). EXP-TRANSFER-004 attributes the TO failure to joint prevalence and feature shift (YES 16%; SMD drought/fire_t ≈ 0.8). EXP-TRANSFER-005 shows that dropping same-day fire_t leaves calibrated MA/PI precision nearly unchanged (76.4%→73.4%; 68.6%→66.5%), so the transfer finding is not a same-day label reconstruction artifact. EXP-TRANSFER-006/007 replicate CE+τ* across dry seasons 2023–2025 with significant bootstrap ΔP on MA/PI, leave-one-municipality-out precision 0.88±0.08 on Ceará, and a top-30 sensitivity check. EXP-TRANSFER-010 shows Maranhão CE+τ* precision holds on 212 municipalities (near-statewide). EXP-TRANSFER-008/009 corroborate municipal hotspot activity with MapBiomas Fire Collection 5: annual burned area vs focos Spearman ρ=0.93 (n=120), and month-resolved GeoTIFF burned area vs focos ρ=0.84 (n=720 mun×month; 99.7% of BA-positive months have INPE focos). The protocol is useful as a low-false-alarm operating point where agencies accept lower recall (MA/PI) and flags where local rules remain preferable (TO under low prevalence). Findings concern hotspot-based municipal prioritization—not daily burned-area mapping. This is a preprint submitted to Remote Sensing Applications: Society and Environment (RSASE). It has not been peer reviewed. The record is an unpublished draft.

Zenodo (CERN European Organization for Nuclear Research)
Saint Joseph University (LB), University of Saint Joseph (US), Saxion (NL), Universidade de Fortaleza (BR)
Sustainable cities and communities
Fire effects on ecosystems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon