StageMatch: Cross-domain estimation of energy storage battery health degradation via degradation-stage matching and soft-weighted adaptation
1.1 ML2032 The battery identifiers for Cell1–Cell16 are '2-1', '2-2', '2-3', '2-4', '2-5', '2-6', '2-7', '2-8', '3-1', '3-2', '3-3', '3-4', '3-5', '3-6', '3-7', and '3-8'. These are lithium–manganese coin cells with specially treated MnO₂ cathodes and lithium–aluminum alloy anodes. The nominal capacity is 65 mAh, and the nominal voltage is 3.0 V. Cycling tests were conducted at room temperature. The charging protocol consisted of constant-current–constant-voltage (CC–CV) charging, followed by constant-current discharging. The charging and discharging rates were 0.1C, and the cutoff current was 0.01C. The charging cutoff voltage and discharging cutoff voltage (V1 and V2) were configured as follows: - For '2-1', '2-2', '2-3', and '3-1', V1 and V2 were 3 V and 2 V, respectively. - For '2-4', '2-5', '2-6', and '3-3', V1 and V2 were 3 V and 1.5 V, respectively. - For '2-7', '2-8', '3-2', and '3-4', V1 and V2 were 3.2 V and 2 V, respectively. - For '3-5', '3-6', '3-7', and '3-8', V1 and V2 were 3.2 V and 1.5 V, respectively. The number of complete charge–discharge cycles is reported as 100–300. At experiment termination, remaining health at the EOL test point ranged from 5% to 15% across cells (the most degraded cell ended at 5% and the least degraded cell at 15%). 1.2 LIR2032 The battery identifiers for Cell17–Cell37 are '8-1', '8-2', '8-3', '8-7', '9-1-1', '9-2-1', '9-3-1', '9-4-1', '9-5-1', '9-6-1', '9-6', '9-7-1', '9-7', '9-8-1', '10-1', '10-2', '10-3', '10-4', '10-5', '10-6', and '10-7'. These are lithium-ion coin cells with LiCoO₂ cathodes and graphite anodes. The nominal capacity is 40 mAh, and the nominal voltage is 3.6 V. Cycling tests were conducted at room temperature. The charging protocol consisted of constant-current–constant-voltage (CC–CV) charging, followed by constant-current discharging, and is denoted by C1–C2. The charging cutoff voltage was 4.2 V, the charging cutoff current was 0.01C, the discharge cutoff voltage was 2.7 V, and the discharge cutoff current was 0.01C. The charging and discharging rates (C1 and C2) were configured as follows: - For '8-1', '8-2', '8-3', and '10-1', both C1 and C2 were 0.5C. - For '9-1-1', '9-2-1', '9-6', and '10-2', C1 and C2 were 0.5C and 1C, respectively. - For '9-3-1', '9-4-1', '9-7', and '10-3', C1 and C2 were 0.5C and 1.25C, respectively. - For '9-5-1', '9-6-1', '10-4', and '10-6', both C1 and C2 were 1C. - For '9-7-1', '9-8-1', '10-5', and '10-7', C1 and C2 were 1C and 1.25C, respectively. Before cycling tests, '8-1', '8-2', '8-3', '9-1-1', '9-2-1', '9-3-1', '9-4-1', '9-5-1', '9-6-1', '9-7-1', and '9-8-1' were stored at room temperature for one month. The number of complete charge–discharge cycles is reported as 135–300. At experiment termination, remaining health at the EOL test point ranged from 50% to 95% across cells (the most degraded cell ended at 50% and the least degraded cell at 95%). 1.3 LIR2016 The battery identifiers for Cell38–Cell42 are '9-1', '9-2', '9-3', '9-4', and '9-5'. These are lithium-ion coin cells with LiCoO₂ cathodes and graphite anodes. The nominal capacity is 18 mAh, and the nominal voltage is 3.6 V. Cycling tests were conducted at room temperature. The charging protocol consisted of constant-current–constant-voltage (CC–CV) charging, followed by constant-current discharging. For '9-1', the battery was charged at a constant current of 18 mA (1C) until the voltage reached the cutoff value of 4.2 V, followed by constant-voltage charging at 4.2 V until the cutoff current reached 0.18 mA (0.01C). Discharging was performed at a constant current of 18 mA (1C) until the voltage reached the cutoff value of 2.7 V. For '9-2', '9-3', '9-4', and '9-5', the charging procedure was identical: a constant current of 18 mA (1C) was applied until the voltage reached 4.2 V, followed by constant-voltage charging at 4.2 V until the cutoff current reached 0.18 mA (0.01C). Discharging was performed at a constant current of 36 mA (2C) until the voltage reached the cutoff value of 2.7 V. The number of complete charge–discharge cycles ranged from 180 to 300. At experiment termination, remaining health at the EOL test point ranged from 35% to 65% across cells (the most degraded cell ended at 35% and the least degraded cell at 65%).
Authors
- Changsheng Zhao (ORCID: https://orcid.org/0009-0004-6014-5268)
Institutions
- South China University of Technology (CN)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-24
- DOI
- https://doi.org/10.5281/zenodo.24457233
- Primary Topic
- Battery Modeling and Management
- Type
- article
- Field-Weighted Citation Impact
- 0.00