Central Composite Design-Based Optimization of a CMC/HA/PEO Hydrogel Matrix as Cargo Delivery Vehicle: Rheological and Textural Attributes

Impaired healing, post-operative tissue adhesion and, after oncological surgery, residual tumour cells remain major challenges in the wound bed left by surgical resection. We developed and optimized a potentially bioadhesive carboxymethyl cellulose (CMC)/hyaluronic acid (HA)/polyethylene oxide (PEO) hydrogel as a cargo delivery vehicle for the surgical wound bed. A rotatable central composite design (CCD) was constructed with CMC and HA (each 0.417–0.983 g/25 mL buffer) as independent variables at a fixed PEO content (25 mg). Viscosity at 20 rpm, hardness, compressibility, adhesiveness, and cohesiveness were modelled with quadratic polynomials over thirteen runs. All models were significant (model p ≤ 0.0042; adequate precision > 9), with R2 of 0.947–0.998 and a non-significant lack of fit for all responses except cohesiveness, which was interpreted qualitatively. CMC was the strongest contributor to viscosity, hardness, and compressibility, while HA dominated adhesiveness. Numerical optimization yielded 0.500 g CMC, 0.900 g HA, and 25 mg PEO per 25 mL of buffer, and all measured responses (viscosity of 258.7 Pa·s; hardness of 0.388 N; compressibility of 1.102 N·s; adhesiveness of 0.653 N·s; cohesiveness of 0.968) fell within the 95% confidence interval of the predicted point. The optimized hydrogel showed a maximum detachment force of 2.713 ± 0.019 N and a work of mucoadhesion of 2.424 ± 0.216 N·s on a mucin wetted surface, which were about 4.7-fold and 49-fold higher than those of the control without hydrogel. The optimized gel preserved its structural integrity and cohesiveness during 6 months of storage at 4 °C, with only a moderate softening that levelled off after the first month. These results support the formulation as a robust matrix for further development in local drug applications.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2026-11-24
DOI
https://doi.org/10.3390/molecules31234278
Primary Topic
Hydrogels: synthesis, properties, applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Central Composite Design-Based Optimization of a CMC/HA/PEO Hydrogel Matrix as Cargo Delivery Vehicle: Rheological and Textural Attributes

Umut Can Öz, Süheyl Furkan KONCA, Asuman Bozkır, Özge Inal
3 links
Molecules
Hydrogels: synthesis, properties, applications
article

Central Composite Design-Based Optimization of a CMC/HA/PEO Hydrogel Matrix as Cargo Delivery Vehicle: Rheological and Textural Attributes

Umut Can Öz, Süheyl Furkan KONCA, Asuman Bozkır, Özge Inal
article en

Abstract

Impaired healing, post-operative tissue adhesion and, after oncological surgery, residual tumour cells remain major challenges in the wound bed left by surgical resection. We developed and optimized a potentially bioadhesive carboxymethyl cellulose (CMC)/hyaluronic acid (HA)/polyethylene oxide (PEO) hydrogel as a cargo delivery vehicle for the surgical wound bed. A rotatable central composite design (CCD) was constructed with CMC and HA (each 0.417–0.983 g/25 mL buffer) as independent variables at a fixed PEO content (25 mg). Viscosity at 20 rpm, hardness, compressibility, adhesiveness, and cohesiveness were modelled with quadratic polynomials over thirteen runs. All models were significant (model p ≤ 0.0042; adequate precision > 9), with R2 of 0.947–0.998 and a non-significant lack of fit for all responses except cohesiveness, which was interpreted qualitatively. CMC was the strongest contributor to viscosity, hardness, and compressibility, while HA dominated adhesiveness. Numerical optimization yielded 0.500 g CMC, 0.900 g HA, and 25 mg PEO per 25 mL of buffer, and all measured responses (viscosity of 258.7 Pa·s; hardness of 0.388 N; compressibility of 1.102 N·s; adhesiveness of 0.653 N·s; cohesiveness of 0.968) fell within the 95% confidence interval of the predicted point. The optimized hydrogel showed a maximum detachment force of 2.713 ± 0.019 N and a work of mucoadhesion of 2.424 ± 0.216 N·s on a mucin wetted surface, which were about 4.7-fold and 49-fold higher than those of the control without hydrogel. The optimized gel preserved its structural integrity and cohesiveness during 6 months of storage at 4 °C, with only a moderate softening that levelled off after the first month. These results support the formulation as a robust matrix for further development in local drug applications.

MoleculesVol. 31(23)
Ankara University (TR), Erciyes University (TR)
Ankara Universitesi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Good health and well-being
Hydrogels: synthesis, properties, applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon