Techno‐Economic Assessment of AMP/PZ Solvent for Industrial‐Scale CO 2 Capture From a Refinery Power Plant

The use of blended amine solvents for carbon capture has emerged as a promising alternative to conventional monoethanolamine (MEA) due to their lower regeneration energy and improved thermodynamic performance. In this study, a pilot‐validated techno‐economic evaluation is conducted for an aqueous solvent blend containing 28 wt% 2‐amino‐2‐methyl‐1‐propanol (AMP) and 17 wt% piperazine (PZ), with performance benchmarked against the conventional 30 wt% MEA process. AMP/H 2 O and PZ/H 2 O thermodynamic parameters were regressed from literature using vapor–liquid equilibrium data and implemented in a rate‐based Aspen Plus V14 model with established reaction kinetics. The simulation was validated against pilot plant data, showing average deviations of 4.39% for capture efficiency, solvent loading, and reboiler duty. The validated model was applied to a refinery power plant producing 434 MWe, treating a flue gas stream of 212,600 kg h −1 containing 12.74 mol% CO 2. At 91.28% capture efficiency, optimal performance was achieved at a liquid‐to‐gas ratio of approximately 2.6 and a stripper pressure of 2.2 bar. The AMP/PZ system achieved a specific reboiler duty of 3.57 GJ t −1 CO 2, slightly lower than 3.61 GJ t −1 CO 2 for MEA. The economic assessment estimates a capital cost of $49.69 million and annual operating costs of $24.04 million, resulting in a CO 2 avoidance cost of $95.13 t −1 CO 2. Compared with the published MEA benchmark ($163.05 t −1 CO 2), the proposed AMP/PZ process exhibited lower estimated avoidance cost under the respective process configurations and economic assumptions. These results demonstrate the technical feasibility of the assessed AMP/PZ configuration for refinery‐scale CO 2 capture at an efficiency above 90%, whereas the economic findings should be interpreted in the context of the assumptions and limitations of the comparative assessment.

Authors

Institutions

Publication Details

Journal
Greenhouse Gases Science and Technology
Published
2026-11-24
DOI
https://doi.org/10.1002/ghg.70054
Primary Topic
Carbon Dioxide Capture Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Techno‐Economic Assessment of AMP/PZ Solvent for Industrial‐Scale CO 2 Capture From a Refinery Power Plant

Kabiru Bab Muritala, Jamiu Adetayo Adeniran, Sherif Ishola Mustapha, Saviour Tertindi Tile
1 links
Greenhouse Gases Science and Technology
Carbon Dioxide Capture Technologies
article

Techno‐Economic Assessment of AMP/PZ Solvent for Industrial‐Scale CO 2 Capture From a Refinery Power Plant

Kabiru Bab Muritala, Jamiu Adetayo Adeniran, Sherif Ishola Mustapha, Saviour Tertindi Tile
article en

Abstract

The use of blended amine solvents for carbon capture has emerged as a promising alternative to conventional monoethanolamine (MEA) due to their lower regeneration energy and improved thermodynamic performance. In this study, a pilot‐validated techno‐economic evaluation is conducted for an aqueous solvent blend containing 28 wt% 2‐amino‐2‐methyl‐1‐propanol (AMP) and 17 wt% piperazine (PZ), with performance benchmarked against the conventional 30 wt% MEA process. AMP/H 2 O and PZ/H 2 O thermodynamic parameters were regressed from literature using vapor–liquid equilibrium data and implemented in a rate‐based Aspen Plus V14 model with established reaction kinetics. The simulation was validated against pilot plant data, showing average deviations of 4.39% for capture efficiency, solvent loading, and reboiler duty. The validated model was applied to a refinery power plant producing 434 MWe, treating a flue gas stream of 212,600 kg h −1 containing 12.74 mol% CO 2. At 91.28% capture efficiency, optimal performance was achieved at a liquid‐to‐gas ratio of approximately 2.6 and a stripper pressure of 2.2 bar. The AMP/PZ system achieved a specific reboiler duty of 3.57 GJ t −1 CO 2, slightly lower than 3.61 GJ t −1 CO 2 for MEA. The economic assessment estimates a capital cost of $49.69 million and annual operating costs of $24.04 million, resulting in a CO 2 avoidance cost of $95.13 t −1 CO 2. Compared with the published MEA benchmark ($163.05 t −1 CO 2), the proposed AMP/PZ process exhibited lower estimated avoidance cost under the respective process configurations and economic assumptions. These results demonstrate the technical feasibility of the assessed AMP/PZ configuration for refinery‐scale CO 2 capture at an efficiency above 90%, whereas the economic findings should be interpreted in the context of the assumptions and limitations of the comparative assessment.

Greenhouse Gases Science and Technology
University of Ilorin (NG), Durban University of Technology (ZA), University of the Witwatersrand (ZA)
Ernest Oppenheimer Memorial Trust
Climate action, Affordable and clean energy, Responsible consumption and production
Carbon Dioxide Capture Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon