Two Is Not too Small; a Case of a Ventricular Aveir AR2 for Ventricular Pacing in a 12.2-kg Two-Year-Old

Pacemaker implants in pediatric patients can be filled with potential complications. Epicardial pacemaker implants are the usual mainstay for those under 15 kg and transvenous devices can have infectious and pocket erosion risk. Retrievable leadless pacemakers seem to be a potential option. Retrospective review of a 2-year-old patient with high grade AV block and overall lowering average junctional rate was performed. Internal review board approval was obtained. A 2-year-old, 12.2-kg female underwent successful right internal jugular vein implant of an Aveir AR2 into the right ventricle for backup ventricular pacing need. No complications occurred. Follow-up at 12 months demonstrated a threshold of 0.5 Volts @0.2 ms, impedance at 420 ohms and sensing at 10milliVolts with 30% pacing noted with programming at VVI 50 bpm, with predicted longevity at 20.2 years. Feasibility of internal jugular vein implant of an Aveir AR2 is possible without complication in a 2-year-old, 12.2 kg child. Further prospective studies are needed to assess true feasibility in this population.

Authors

Institutions

Publication Details

Journal
Pediatric Cardiology
Published
2026-11-24
DOI
https://doi.org/10.1007/s00246-026-04536-1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Two Is Not too Small; a Case of a Ventricular Aveir AR2 for Ventricular Pacing in a 12.2-kg Two-Year-Old

Daniel Cortez, Nandita Sharma
2 links
Pediatric Cardiology
Cardiac pacing and defibrillation studies
article

Two Is Not too Small; a Case of a Ventricular Aveir AR2 for Ventricular Pacing in a 12.2-kg Two-Year-Old

Daniel Cortez, Nandita Sharma
article en

Abstract

Pacemaker implants in pediatric patients can be filled with potential complications. Epicardial pacemaker implants are the usual mainstay for those under 15 kg and transvenous devices can have infectious and pocket erosion risk. Retrievable leadless pacemakers seem to be a potential option. Retrospective review of a 2-year-old patient with high grade AV block and overall lowering average junctional rate was performed. Internal review board approval was obtained. A 2-year-old, 12.2-kg female underwent successful right internal jugular vein implant of an Aveir AR2 into the right ventricle for backup ventricular pacing need. No complications occurred. Follow-up at 12 months demonstrated a threshold of 0.5 Volts @0.2 ms, impedance at 420 ohms and sensing at 10milliVolts with 30% pacing noted with programming at VVI 50 bpm, with predicted longevity at 20.2 years. Feasibility of internal jugular vein implant of an Aveir AR2 is possible without complication in a 2-year-old, 12.2 kg child. Further prospective studies are needed to assess true feasibility in this population.

Pediatric Cardiology
University of California Davis Medical Center (US), University of California, Davis (US)
University of California, Davis
Good health and well-being
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Two Is Not too Small; a Case of a Ventricular Aveir AR2 for Ventricular Pacing in a 12.2-kg Two-Year-Old — Daniel Cortez, Nandita Sharma · Pediatric Cardiology (2026) | TGRS Research Map | TGRS