Periprosthetic femoral fracture risk varies across cemented femoral stem designs: a nationwide Swiss joint registry study

PURPOSE: Cemented fixation is associated with lower periprosthetic femoral fracture (PPFx) risk than uncemented fixation; however, risk variations between cemented stem fixation philosophies remain unclear. Using data from the Swiss National Joint Registry (SIRIS), this nationwide study compared PPFx risk among different cemented femoral stem designs used in primary hip arthroplasty. METHODS: A total of 290,639 primary arthroplasties performed between 2012 and 2025 were identified in SIRIS. Cemented stems were classified into Type 1 traditional (Type 1t) taper-slip with a distal centralizer, Type 1 fit-and-fill (Type 1ff), or Type 2 composite beam designs. Multivariable Cox regression models assessed associations between stem design and PPFx risk, stratified by indication (osteoarthritis versus fracture) and adjusted for age and sex. RESULTS: Among 290,639 primary arthroplasties, 2149 (0.74%) were revised for PPFx. Cemented fixation was associated with a lower risk than uncemented fixation in both osteoarthritis (hazard ratio (HR) 0.30-0.70) and fracture patients (HR 0.26-0.74). In THA for osteoarthritis, Type 2 composite beams stems showed the lowest fracture risk and remained superior to Type 1ff stems after multivariable adjustment (HR 0.63, 95% CI 0.41-0.97). Type 1t stems were associated with a lower risk in primary analysis but not after additional adjustment. In fracture patients, no significant differences were observed between cemented stem designs. Male sex (HR 1.62-1.67) and age ≥ 80 years (HR 1.67, 95% CI 1.20-2.32) were associated with a higher risk. Type 2 performed best in osteoarthritis, while no differences were observed in fracture patients. CONCLUSION: Cemented fixation was associated with a lower PPFx risk, but not uniformly across designs. In osteoarthritis, Type 2 composite-beam stems showed the most robust risk reduction compared with Type 1ff fit-and-fill stems, despite Type 1ff being the most used design in Switzerland. In fracture patients, no cemented design was superior.

Authors

Institutions

Publication Details

Journal
International Orthopaedics
Published
2026-11-24
DOI
https://doi.org/10.1007/s00264-026-07075-9
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Periprosthetic femoral fracture risk varies across cemented femoral stem designs: a nationwide Swiss joint registry study

Marlene Mauch, Ioanna Bozonelou, Christian Brand, Karl Kilian Stoffel et al.
6 links
International Orthopaedics
Orthopaedic implants and arthroplasty
article

Periprosthetic femoral fracture risk varies across cemented femoral stem designs: a nationwide Swiss joint registry study

Marlene Mauch, Ioanna Bozonelou, Christian Brand, Karl Kilian Stoffel, Tamara Horn Lang
article en

Abstract

PURPOSE: Cemented fixation is associated with lower periprosthetic femoral fracture (PPFx) risk than uncemented fixation; however, risk variations between cemented stem fixation philosophies remain unclear. Using data from the Swiss National Joint Registry (SIRIS), this nationwide study compared PPFx risk among different cemented femoral stem designs used in primary hip arthroplasty. METHODS: A total of 290,639 primary arthroplasties performed between 2012 and 2025 were identified in SIRIS. Cemented stems were classified into Type 1 traditional (Type 1t) taper-slip with a distal centralizer, Type 1 fit-and-fill (Type 1ff), or Type 2 composite beam designs. Multivariable Cox regression models assessed associations between stem design and PPFx risk, stratified by indication (osteoarthritis versus fracture) and adjusted for age and sex. RESULTS: Among 290,639 primary arthroplasties, 2149 (0.74%) were revised for PPFx. Cemented fixation was associated with a lower risk than uncemented fixation in both osteoarthritis (hazard ratio (HR) 0.30-0.70) and fracture patients (HR 0.26-0.74). In THA for osteoarthritis, Type 2 composite beams stems showed the lowest fracture risk and remained superior to Type 1ff stems after multivariable adjustment (HR 0.63, 95% CI 0.41-0.97). Type 1t stems were associated with a lower risk in primary analysis but not after additional adjustment. In fracture patients, no significant differences were observed between cemented stem designs. Male sex (HR 1.62-1.67) and age ≥ 80 years (HR 1.67, 95% CI 1.20-2.32) were associated with a higher risk. Type 2 performed best in osteoarthritis, while no differences were observed in fracture patients. CONCLUSION: Cemented fixation was associated with a lower PPFx risk, but not uniformly across designs. In osteoarthritis, Type 2 composite-beam stems showed the most robust risk reduction compared with Type 1ff fit-and-fill stems, despite Type 1ff being the most used design in Switzerland. In fracture patients, no cemented design was superior.

International Orthopaedics
University of Bern (CH), Bern University of Applied Sciences (CH), Swissmedic (CH), University of Basel (CH), University Hospital of Basel (CH), Kantonsspital Münsterlingen (CH)
Universität Basel
Good health and well-being
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon