Research on trace synovial fluid in multiple-stage osteoarthritis using HOF-ATR-FTIR spectroscopy and machine learning

Osteoarthritis (OA) is an irreversible degenerative joint disease, which requires sensitive and minimally invasive diagnostic approaches for early detection. A novel strategy based on a self-designed hollow optical fiber attenuated total reflection FTIR (HOF-ATR-FTIR) probe for trace synovial fluid (SF) detection was proposed. The HOF-ATR architecture enables high-quality infrared spectral acquisition with flexible sampling, ultra-low sample consumption, and remote detection. Compared with micro-Raman detection, this approach enables faster trace-volume analysis without prolonged drying or additional signal enhancement. It effectively eliminates coffee-ring induced molecular redistribution during droplet drying, thereby improving spectral quality, measurement reproducibility, and quantitative reliability. Spectral analysis revealed progressive decreases in hyaluronic acid and glycosaminoglycans, accompanied by increased collagen peptides in SF during OA progression. A mechanism-constrained feature selection targeting the polysaccharide region (1000–1300 cm−1) was further introduced to directly associate spectral signatures with OA-related biochemical alterations, transforming the classification from conventional full-spectrum modeling toward biologically guided modeling. Combined with machine learning, the proposed method achieved 94.29% classification accuracy between early and non-early OA with an AUC of 0.932, indicating promising classification performance in the present cohort. Overall, the integration of HOF-ATR-FTIR spectroscopy detection points out OA progression by spectral analysis on SF with high spectral quality, and provides a reliable and minimally invasive framework with mechanism-constrained modeling for OA diagnosis, offering strong potential for early OA assessment and future clinical translation.

Authors

Institutions

Publication Details

Journal
Spectroscopy Letters
Published
2026-11-24
DOI
https://doi.org/10.1080/00387010.2026.2761921
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Research on trace synovial fluid in multiple-stage osteoarthritis using HOF-ATR-FTIR spectroscopy and machine learning

Jiachun Dong, Linwei Shang, Jianhua Yin, Jinjin Wu et al.
3 links
Spectroscopy Letters
Spectroscopy Techniques in Biomedical and Chemical Research
article

Research on trace synovial fluid in multiple-stage osteoarthritis using HOF-ATR-FTIR spectroscopy and machine learning

Jiachun Dong, Linwei Shang, Jianhua Yin, Jinjin Wu, Bozhan Li, Huijie Wang, Xinyi Ji, Chaochao Ji
article en

Abstract

Osteoarthritis (OA) is an irreversible degenerative joint disease, which requires sensitive and minimally invasive diagnostic approaches for early detection. A novel strategy based on a self-designed hollow optical fiber attenuated total reflection FTIR (HOF-ATR-FTIR) probe for trace synovial fluid (SF) detection was proposed. The HOF-ATR architecture enables high-quality infrared spectral acquisition with flexible sampling, ultra-low sample consumption, and remote detection. Compared with micro-Raman detection, this approach enables faster trace-volume analysis without prolonged drying or additional signal enhancement. It effectively eliminates coffee-ring induced molecular redistribution during droplet drying, thereby improving spectral quality, measurement reproducibility, and quantitative reliability. Spectral analysis revealed progressive decreases in hyaluronic acid and glycosaminoglycans, accompanied by increased collagen peptides in SF during OA progression. A mechanism-constrained feature selection targeting the polysaccharide region (1000–1300 cm−1) was further introduced to directly associate spectral signatures with OA-related biochemical alterations, transforming the classification from conventional full-spectrum modeling toward biologically guided modeling. Combined with machine learning, the proposed method achieved 94.29% classification accuracy between early and non-early OA with an AUC of 0.932, indicating promising classification performance in the present cohort. Overall, the integration of HOF-ATR-FTIR spectroscopy detection points out OA progression by spectral analysis on SF with high spectral quality, and provides a reliable and minimally invasive framework with mechanism-constrained modeling for OA diagnosis, offering strong potential for early OA assessment and future clinical translation.

Spectroscopy Letters
People's Hospital of Bishan District (CN), Anshan Hospital (CN), Nanjing Medical University (CN), Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China, Government of Jiangsu Province, Nanjing University of Aeronautics and Astronautics, Nanjing Medical University, Fundamental Research Funds for the Central Universities
Good health and well-being
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon