Improved performance in double-shell implosions through ablator-gap reduction at the National Ignition Facility

The performance of Double Shell (DS) capsules on the National Ignition Facility has improved rapidly, with neutron yields and ion temperatures increasing nearly 30 × and 2 × , respectively, over the first 11 shots. These improvements result from advances in capsule design and fabrication aimed at mitigating key degradation sources, including the ablator joint gap, fill tube, and surface roughness. Experimental measurements of x-ray self-emission and hot-spot velocities, combined with radiation-hydrodynamics simulations, reveal that DS implosions began in an ablator-gap dominated degradation regime wherein reducing the ablator gap size and impact led to significant improvements in performance. As the ablator gap was nearly closed, the impact of the ablator gap was reduced so significantly that the fill tube became the leading degradation source in the best performing DS implosions. From these results, fill-tube mitigation emerges as the next priority in DS development.

Authors

Publication Details

Journal
Physical review. E
Published
2026-11-24
DOI
https://doi.org/10.1103/1x2j-9bbz
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Improved performance in double-shell implosions through ablator-gap reduction at the National Ignition Facility

P. Donovan, J. W. Crippen, Nikolaus Christiansen, M. Durocher et al.
2 links
Physical review. E
Laser-Plasma Interactions and Diagnostics
article

Improved performance in double-shell implosions through ablator-gap reduction at the National Ignition Facility

P. Donovan, J. W. Crippen, Nikolaus Christiansen, M. Durocher, E. Gallardo-Diaz, E. N. Loomis, R. F. Sacks, S. D. Negussie, H. F. Robey, B. M. Medina, P. M. Kozlowski, H. Xu, A. M. Rasmus, S. Palaniyappan, R. S. Lester, K. H. Ma, B. M. Patterson, J. P. Sauppe, D. W. Schmidt, T. E. Quintana, R. L. Scott, C.-S. Wong, S. J. Stringfield, Z. L. Mohamed, W. Sweet
article en

Abstract

The performance of Double Shell (DS) capsules on the National Ignition Facility has improved rapidly, with neutron yields and ion temperatures increasing nearly 30 × and 2 × , respectively, over the first 11 shots. These improvements result from advances in capsule design and fabrication aimed at mitigating key degradation sources, including the ablator joint gap, fill tube, and surface roughness. Experimental measurements of x-ray self-emission and hot-spot velocities, combined with radiation-hydrodynamics simulations, reveal that DS implosions began in an ablator-gap dominated degradation regime wherein reducing the ablator gap size and impact led to significant improvements in performance. As the ablator gap was nearly closed, the impact of the ablator gap was reduced so significantly that the fill tube became the leading degradation source in the best performing DS implosions. From these results, fill-tube mitigation emerges as the next priority in DS development.

Physical review. E
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.