Comparison of Fine-tuned and Frozen BiomedCLIP Encoders for Image Captioning of Cervical VIA Images with LSTM and BiLSTM Decoders

Visual Inspection with Acetic Acid (VIA) is a low-cost cervical cancer screening method, but its interpretation depends on the examiner and is often subjective. Existing artificial intelligence models for VIA images mostly output class labels or lesion areas without stating the visual findings behind the decision. This study applies image captioning to describe the findings in a VIA image as a sentence and examines which component most affects caption quality. Four configurations were built by combining two encoder treatments, a fine-tuned and a frozen BiomedCLIP encoder, with two decoders, Long Short-Term Memory (LSTM) and Bidirectional LSTM (BiLSTM). The dataset consists of 185 image–caption pairs from the IARC Image Bank VIA, split by stratification into 166 training and 19 test pairs. Caption quality was measured with BLEU, METEOR, ROUGE-L, and CIDEr, supported by the cosine similarity between test image features and the conclusion accuracy against a majority-class baseline. The fine-tuned encoder with the BiLSTM decoder achieved the highest scores, with a BLEU-4 of 74.98, METEOR of 83.77, ROUGE-L of 80.70, and CIDEr of 7.0212. The frozen encoder produced nearly uniform features, with a cosine similarity of 0.7634 compared with 0.2192 after fine-tuning, and generated only one or two distinct sentences across 19 test images. Its conclusion accuracy was 47.06%, below the baseline of 52.94%, whereas the fine-tuned encoder reached 70.59%. These results indicate that encoder fine-tuning is the main factor in captioning VIA images, while the choice between LSTM and BiLSTM has a smaller effect.

Authors

Institutions

Publication Details

Journal
Teknika
Published
2026-11-24
DOI
https://doi.org/10.34148/teknika.v15i3.1593
Primary Topic
Multimodal Machine Learning Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of Fine-tuned and Frozen BiomedCLIP Encoders for Image Captioning of Cervical VIA Images with LSTM and BiLSTM Decoders

Siti Nurmaini, Tengku Kevin Juldianto, Firdaus
2 links
Teknika
Multimodal Machine Learning Applications
article

Comparison of Fine-tuned and Frozen BiomedCLIP Encoders for Image Captioning of Cervical VIA Images with LSTM and BiLSTM Decoders

Siti Nurmaini, Tengku Kevin Juldianto, Firdaus
article en

Abstract

Visual Inspection with Acetic Acid (VIA) is a low-cost cervical cancer screening method, but its interpretation depends on the examiner and is often subjective. Existing artificial intelligence models for VIA images mostly output class labels or lesion areas without stating the visual findings behind the decision. This study applies image captioning to describe the findings in a VIA image as a sentence and examines which component most affects caption quality. Four configurations were built by combining two encoder treatments, a fine-tuned and a frozen BiomedCLIP encoder, with two decoders, Long Short-Term Memory (LSTM) and Bidirectional LSTM (BiLSTM). The dataset consists of 185 image–caption pairs from the IARC Image Bank VIA, split by stratification into 166 training and 19 test pairs. Caption quality was measured with BLEU, METEOR, ROUGE-L, and CIDEr, supported by the cosine similarity between test image features and the conclusion accuracy against a majority-class baseline. The fine-tuned encoder with the BiLSTM decoder achieved the highest scores, with a BLEU-4 of 74.98, METEOR of 83.77, ROUGE-L of 80.70, and CIDEr of 7.0212. The frozen encoder produced nearly uniform features, with a cosine similarity of 0.7634 compared with 0.2192 after fine-tuning, and generated only one or two distinct sentences across 19 test images. Its conclusion accuracy was 47.06%, below the baseline of 52.94%, whereas the fine-tuned encoder reached 70.59%. These results indicate that encoder fine-tuning is the main factor in captioning VIA images, while the choice between LSTM and BiLSTM has a smaller effect.

TeknikaVol. 15(3)
Sriwijaya University (ID)
Good health and well-being
Multimodal Machine Learning Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon