Non-Invasive Liver Scores Can Predict Early Mortality After the Implantation of Durable Left Ventricular Assist Devices

Background/Objectives: Patient selection for durable left ventricular assist device (dLVAD) therapy remains challenging. Non-invasive liver scores have gained attention as potential predictors of heart failure-related mortality. Methods: A total of 323 patients undergoing dLVAD implantation were divided into a contemporary (predominantly Heartmate 3) cohort (2017–2024, n = 184) and a historical (predominantly HVAD) cohort (2008–2016, n = 139). Non-invasive liver scores were retrospectively calculated from preoperative laboratory parameters and correlated with 30-day mortality and severe right heart failure requiring temporary right ventricular assist device (tRVAD)implantation, with subsequent validation in our historical cohort. Results: Logistic regression and receiver operating characteristic analysis showed that the AST-to-platelet ratio index (APRI) was associated with the risk of tRVAD, with an area under the curve (AUC) of 0.71 (p < 0.01). The fibrosis-4 score (FIB-4, AUC = 0.82), the model of end-stage liver disease (MELD, AUC = 0.93), the non-alcoholic fatty liver disease score (NAFLD, AUC = 0.78), and APRI (AUC = 0.84) were the best scores associated with 30-day mortality after dLVAD implantation. After validation in the historical cohort, FIB-4 ≥ 2.25 and MELD ≥ 14.5 were identified as optimal risk scores and their cut-offs. In contrast, APRI failed to predict tRVAD implantation in the historical cohort (AUC = 0.31). Conclusions: Non-invasive liver scores offer a promising approach to improve risk stratification for dLVAD implantation. FIB-4 and MELD were consistently associated with 30-day mortality in univariate analyses, while APRI may be a valuable score for severe right heart failure requiring tRVAD implantation following univariate analysis in the contemporary cohort but not in the historical cohort. After adjustment for age and INTERMACS profile, FIB-4 was still independently associated with 30-day mortality. Nevertheless, the exact optimal cut-off values need to be further evaluated in larger cohorts.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-24
DOI
https://doi.org/10.3390/jcm15239216
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Non-Invasive Liver Scores Can Predict Early Mortality After the Implantation of Durable Left Ventricular Assist Devices

Moritz Benjamin Immohr, Nikolaus Pizanis, Payam Akhyari, Yukiharu Sugimura et al.
4 links
Journal of Clinical Medicine
Mechanical Circulatory Support Devices
article

Non-Invasive Liver Scores Can Predict Early Mortality After the Implantation of Durable Left Ventricular Assist Devices

Moritz Benjamin Immohr, Nikolaus Pizanis, Payam Akhyari, Yukiharu Sugimura, Arash Mehdiani, Tienush Rassaf, Markus Kamler, Achim Koch, Lars Michel
article en

Abstract

Background/Objectives: Patient selection for durable left ventricular assist device (dLVAD) therapy remains challenging. Non-invasive liver scores have gained attention as potential predictors of heart failure-related mortality. Methods: A total of 323 patients undergoing dLVAD implantation were divided into a contemporary (predominantly Heartmate 3) cohort (2017–2024, n = 184) and a historical (predominantly HVAD) cohort (2008–2016, n = 139). Non-invasive liver scores were retrospectively calculated from preoperative laboratory parameters and correlated with 30-day mortality and severe right heart failure requiring temporary right ventricular assist device (tRVAD)implantation, with subsequent validation in our historical cohort. Results: Logistic regression and receiver operating characteristic analysis showed that the AST-to-platelet ratio index (APRI) was associated with the risk of tRVAD, with an area under the curve (AUC) of 0.71 (p < 0.01). The fibrosis-4 score (FIB-4, AUC = 0.82), the model of end-stage liver disease (MELD, AUC = 0.93), the non-alcoholic fatty liver disease score (NAFLD, AUC = 0.78), and APRI (AUC = 0.84) were the best scores associated with 30-day mortality after dLVAD implantation. After validation in the historical cohort, FIB-4 ≥ 2.25 and MELD ≥ 14.5 were identified as optimal risk scores and their cut-offs. In contrast, APRI failed to predict tRVAD implantation in the historical cohort (AUC = 0.31). Conclusions: Non-invasive liver scores offer a promising approach to improve risk stratification for dLVAD implantation. FIB-4 and MELD were consistently associated with 30-day mortality in univariate analyses, while APRI may be a valuable score for severe right heart failure requiring tRVAD implantation following univariate analysis in the contemporary cohort but not in the historical cohort. After adjustment for age and INTERMACS profile, FIB-4 was still independently associated with 30-day mortality. Nevertheless, the exact optimal cut-off values need to be further evaluated in larger cohorts.

Journal of Clinical MedicineVol. 15(23)
West German Heart and Vascular Center Essen (DE), University of Duisburg-Essen (DE)
Good health and well-being
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon