An online built-in test diagnosis method for bonding faults in strain-gauge full-bridge sensors
To address the problem that bonding failure in the bridge arms of strain-gauge full bridges used in advanced equipment is highly concealed and difficult to identify online through conventional calibration or manual inspection, this paper proposes an online built-in test (BIT) diagnosis method based on local self-heating excitation by establishing a local self-heating thermal network model for the bridge arm. The proposed method enables addressed detection of bridge-arm bonding faults, with the arm location supplied by the selected excitation channel. Meanwhile, a model-based criterion for the minimum resolvable excitation duration and a healthy-reference fault-decision framework are formulated; normalized cooling-recovery curves are used for qualitative comparison. The results demonstrate the feasibility of using the self-heating response for bonding-fault manifestation and channel-addressed fault detection in the tested cases; statistical diagnostic performance will be assessed in future work.
Authors
- Jiale Tian (ORCID: https://orcid.org/0000-0002-1667-7732)
- Jianan Cao
- Jiaming Xu
- Shihan Yu (ORCID: https://orcid.org/0009-0004-9633-3076)
Institutions
- Xi'an Jiaotong University (CN)
Publication Details
- Journal
- Measurement Science and Technology
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1088/1361-6501/aec61d
- Primary Topic
- VLSI and Analog Circuit Testing
- Type
- article
- Field-Weighted Citation Impact
- 0.00