Centripetal displacement of cervical lymphatic levels during head and neck cancer radiotherapy: dosimetric validation of CTVn optimization
Weight loss during radiotherapy for head and neck cancer can cause medial displacement of the clinical target volume for nodes (CTVn), leading to inadequate target dose coverage. This study aimed to quantify the centripetal displacement of the medial border of cervical lymphatic levels and to translate these data into an optimized CTVn delineation strategy with dosimetric validation. Forty-three patients with head and neck cancer were prospectively enrolled and underwent four computed tomography (CT) scans: before radiotherapy (CT0), at week 3 (CT1), week 5 (CT2), and at the end of radiotherapy (CT3). Medial border zones of levels IIa, IIb, III, and Va were delineated on all scans. The X-values of three-dimensional centroid coordinates were extracted, and medial displacement distances were calculated. Using a self-controlled design, level-specific CTVn expansion margins were applied in the experimental plan, and dosimetric parameters were compared with the standard plan. At the end of radiotherapy, centripetal displacement was most pronounced in level Va (4.42 ± 2.08 mm), followed by level IIb (2.36 ± 1.15 mm) and level III (2.35 ± 0.93 mm); displacement in level IIa was not statistically significant ( P > 0.05). Displacement exhibited an “early acceleration” pattern, with the first 3 weeks accounting for 48.6%–53.8% of the total shift. Body mass index (BMI) decrease correlated strongly with level Va displacement at the end of radiotherapy ( r = 0.721, P < 0.001). Dosimetric comparison revealed no significant differences in any organ-at-risk parameters between the experimental and control plans (P all >0.05). Target coverage (V95%, D95), homogeneity index, and conformity index showed no significant changes. The medial border of cervical lymphatic levels undergoes level-specific centripetal displacement during radiotherapy for head and neck cancer. Expanding the medial CTVn border by 2.4 mm for levels IIb and III and 4.4 mm for level Va compensates for anatomical displacement without increasing dose to organs at risk.
Authors
- Qingying Cui (ORCID: https://orcid.org/0000-0002-9408-7498)
- Shuai Fu (ORCID: https://orcid.org/0000-0002-0298-8433)
- Ruiqing Long (ORCID: https://orcid.org/0009-0000-0386-3053)
- Qing Ye (ORCID: https://orcid.org/0000-0001-6874-5146)
- Chunlei Ge (ORCID: https://orcid.org/0000-0001-8393-8341)
- Cheng Sheng (ORCID: https://orcid.org/0009-0003-4919-7924)
- Fengfeng Jia (ORCID: https://orcid.org/0009-0000-5088-6688)
- Yuan Chen
- Zhiwei Wang
- Zhiqiang Wang (ORCID: https://orcid.org/0000-0002-2490-320X)
- Tao Lu
- Yang Fu
- Fan Zhang
- Min Guo
- Ziqi Yin
- Rui Zhang
Institutions
- Kunming Medical University (CN)
- First Affiliated Hospital of Kunming Medical University (CN)
- Liupanshui Normal University (CN)
- Shougang (China) (CN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1038/s41598-026-80230-9
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China
- Kunming Medical University
- Yunnan Provincial Science and Technology Department