A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment

Gait analysis is commonly used to characterize pathological gait patterns, monitor rehabilitation, and evaluate treatment outcomes. This study evaluated a self-developed, low-cost, portable gait cycle analysis system (GCAS) based on pressure-sensing insoles to measure spatiotemporal gait parameters and plantar center-of-pressure trajectories during walking. The system integrates eight pressure sensors per insole, fuzzy-logic-based gait-phase classification, signal acquisition, and wireless data transmission. Pressure signals were acquired at 100 Hz and classified into four gait phases: heel contact, flat-foot contact, push-off, and swing. To assess measurement consistency, we simultaneously recorded 50 steps for each pairwise comparison of GCAS, AMTI force plate (FP), and Pedar pressure-measuring insole (PMI). GCAS showed lower mean anterior-posterior (AP) trajectory length than PMI and FP, whereas medial-lateral (ML) width showed smaller differences among systems. GCAS also showed lower variability in AP length and ML width than PMI. Bilateral COP analysis showed comparable intersection patterns between GCAS and PMI, with differences of 2.75, 2.51, and 4.10 mm in the horizontal, vertical, and straight-line directions, respectively. In a preliminary clinical assessment, 21 participants in the control group (C) with Kellgren-Lawrence grades 0-2 and 22 participants in the experimental group (E) with grades 3-4 were evaluated. E showed significantly lower walking speed, stride ratio, and HFPS ratio and greater AP variability than C. These findings provide preliminary evidence that GCAS can capture gait characteristics and may support portable assessment of gait abnormalities.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-11-24
DOI
https://doi.org/10.1088/1873-4030/aec5f8
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment

Chin‐Kai Huang, Jing‐Jing Fang, Chien-Hung Chen, Guan-Jyun Song et al.
2 links
Medical Engineering & Physics
Lower Extremity Biomechanics and Pathologies
article

A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment

Chin‐Kai Huang, Jing‐Jing Fang, Chien-Hung Chen, Guan-Jyun Song, Chih-Wei Chang, Sung-Pu Liao
article en

Abstract

Gait analysis is commonly used to characterize pathological gait patterns, monitor rehabilitation, and evaluate treatment outcomes. This study evaluated a self-developed, low-cost, portable gait cycle analysis system (GCAS) based on pressure-sensing insoles to measure spatiotemporal gait parameters and plantar center-of-pressure trajectories during walking. The system integrates eight pressure sensors per insole, fuzzy-logic-based gait-phase classification, signal acquisition, and wireless data transmission. Pressure signals were acquired at 100 Hz and classified into four gait phases: heel contact, flat-foot contact, push-off, and swing. To assess measurement consistency, we simultaneously recorded 50 steps for each pairwise comparison of GCAS, AMTI force plate (FP), and Pedar pressure-measuring insole (PMI). GCAS showed lower mean anterior-posterior (AP) trajectory length than PMI and FP, whereas medial-lateral (ML) width showed smaller differences among systems. GCAS also showed lower variability in AP length and ML width than PMI. Bilateral COP analysis showed comparable intersection patterns between GCAS and PMI, with differences of 2.75, 2.51, and 4.10 mm in the horizontal, vertical, and straight-line directions, respectively. In a preliminary clinical assessment, 21 participants in the control group (C) with Kellgren-Lawrence grades 0-2 and 22 participants in the experimental group (E) with grades 3-4 were evaluated. E showed significantly lower walking speed, stride ratio, and HFPS ratio and greater AP variability than C. These findings provide preliminary evidence that GCAS can capture gait characteristics and may support portable assessment of gait abnormalities.

Medical Engineering & Physics
Kaohsiung Veterans General Hospital (TW), National Cheng Kung University (TW)
Kaohsiung Veterans General Hospital, National Science and Technology Council
Good health and well-being
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon