Comparative Evaluation of Two-Dimensional Axial and Three-Dimensional Multiplanar Reconstruction for Right Mainstem Bronchial Morphometry

Background: The right mainstem bronchus (RMSB) is short and highly variable in length, making right-sided double-lumen tube and bronchial blocker placement technically demanding. Two-dimensional (2D) axial computed tomography (CT) may systematically overestimate bronchial length relative to three-dimensional (3D) multiplanar reconstruction (MPR) because the RMSB courses obliquely to the axial plane. This study compared 2D and 3D CT measurements of RMSB length referenced to the right upper lobe (RUL) bronchial orifice. Methods: In this retrospective cross-sectional study, paired 2D and 3D measurements of the superior and inferior RMSB distances were obtained from preoperative chest CT in patients undergoing thoracic surgery. Agreement was assessed using Bland–Altman analysis and the intraclass correlation coefficient [ICC(2,1)]; paired measurements were compared with two-sided paired-samples t tests. Results: A total of 697 patients (405 male, 292 female) were analyzed. 2D measurements were significantly longer than 3D measurements for both distances (all p < 0.001). Mean bias (2D − 3D) was 2.56 mm for the superior distance (95% limits of agreement −1.67 to 6.79 mm; ICC 0.743) and 2.74 mm for the inferior distance (95% limits of agreement −2.34 to 7.83 mm; ICC 0.714). The direction of bias was consistent across sex, age, and height subgroups. Conclusions: Compared with 3D MPR, 2D axial CT consistently yields longer RMSB length measurements, and limits of agreement between the two methods are too wide for them to be used interchangeably in individual patients. 3D MPR may therefore be the preferred modality for planning right-sided lung isolation, particularly when airway anatomy is challenging.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-24
DOI
https://doi.org/10.3390/diagnostics16233945
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Evaluation of Two-Dimensional Axial and Three-Dimensional Multiplanar Reconstruction for Right Mainstem Bronchial Morphometry

Evgeni Gershman, Ruth Shaylor, David E. Kozuch, Jacob Dyckman et al.
2 links
Diagnostics
Airway Management and Intubation Techniques
article

Comparative Evaluation of Two-Dimensional Axial and Three-Dimensional Multiplanar Reconstruction for Right Mainstem Bronchial Morphometry

Evgeni Gershman, Ruth Shaylor, David E. Kozuch, Jacob Dyckman, Netanel Sharabi
article en

Abstract

Background: The right mainstem bronchus (RMSB) is short and highly variable in length, making right-sided double-lumen tube and bronchial blocker placement technically demanding. Two-dimensional (2D) axial computed tomography (CT) may systematically overestimate bronchial length relative to three-dimensional (3D) multiplanar reconstruction (MPR) because the RMSB courses obliquely to the axial plane. This study compared 2D and 3D CT measurements of RMSB length referenced to the right upper lobe (RUL) bronchial orifice. Methods: In this retrospective cross-sectional study, paired 2D and 3D measurements of the superior and inferior RMSB distances were obtained from preoperative chest CT in patients undergoing thoracic surgery. Agreement was assessed using Bland–Altman analysis and the intraclass correlation coefficient [ICC(2,1)]; paired measurements were compared with two-sided paired-samples t tests. Results: A total of 697 patients (405 male, 292 female) were analyzed. 2D measurements were significantly longer than 3D measurements for both distances (all p < 0.001). Mean bias (2D − 3D) was 2.56 mm for the superior distance (95% limits of agreement −1.67 to 6.79 mm; ICC 0.743) and 2.74 mm for the inferior distance (95% limits of agreement −2.34 to 7.83 mm; ICC 0.714). The direction of bias was consistent across sex, age, and height subgroups. Conclusions: Compared with 3D MPR, 2D axial CT consistently yields longer RMSB length measurements, and limits of agreement between the two methods are too wide for them to be used interchangeably in individual patients. 3D MPR may therefore be the preferred modality for planning right-sided lung isolation, particularly when airway anatomy is challenging.

DiagnosticsVol. 16(23)
Tel Aviv University (IL), Hebrew University of Jerusalem (IL), Tel Aviv Sourasky Medical Center (IL), Kaplan Medical Center (IL), Weizmann Institute of Science (IL)
Good health and well-being
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon