Association of Pavlik Harness Use and Compliance with Closed Reduction Outcomes in Developmental Dysplasia of the Hip: A Retrospective Cohort Study with a Mean Three-Year Follow-Up

Background/Objectives: Parental compliance with the Pavlik harness has rarely been analyzed as a separate variable in studies of closed reduction (CR) after harness treatment. This study evaluated whether Pavlik harness use and compliance before CR are associated with CR success, avascular necrosis (AVN), and residual acetabular dysplasia (RAD) in developmental dysplasia of the hip (DDH). Methods: We retrospectively analyzed 150 hips in 87 patients who underwent CR and hip spica casting before 12 months of age between January 2020 and June 2021. Hips were grouped by pre-CR harness use: no harness (n = 66), improper use (n = 25), and proper use (n = 59). Improper use was defined as insufficient daily wear, incorrect application despite training, premature discontinuation, or continuation of the harness despite a recommendation for CR. Loss of reduction requiring further surgery was defined as failure. Clustering of hips within families was accounted for with generalized estimating equations (GEE). Results: At a mean follow-up of 38.6 ± 4.9 months, CR succeeded in 92.0% of hips. Failure rates were 20.0% with improper use, 6.1% with no harness, and 5.1% with proper use (p = 0.076). In GEE, the odds ratio (OR) for improper versus proper use was 4.48 (95% CI 0.67–29.95) and 3.28 (95% CI 0.49–22.04) after adjustment for International Hip Dysplasia Institute (IHDI) grade 4, which was strongly associated with failure (OR 15.61; 95% CI 3.92–62.23). Among successfully reduced hips, AVN (10.1%) and RAD (6.5%) did not differ significantly between groups (p = 0.128 and p = 0.121). The mean acetabular index decreased from 37.1° to 18.7° (p < 0.001). Conclusions: In this cohort, CR failure was numerically more frequent after improper Pavlik harness use, but the difference was not statistically significant and was partly explained by disease severity. No significant differences in AVN or RAD were detected. Given the small number of events, these findings should be considered hypothesis-generating, and larger studies with prospectively documented compliance are needed.

Authors

Institutions

Publication Details

Journal
Children
Published
2026-11-24
DOI
https://doi.org/10.3390/children13121640
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association of Pavlik Harness Use and Compliance with Closed Reduction Outcomes in Developmental Dysplasia of the Hip: A Retrospective Cohort Study with a Mean Three-Year Follow-Up

Ömercan Sepetçi, Hasan Mehmet Tıraş, Ahmet Yiğit Kaptan, Burak Bozdoğan et al.
Children
Hip disorders and treatments
article

Association of Pavlik Harness Use and Compliance with Closed Reduction Outcomes in Developmental Dysplasia of the Hip: A Retrospective Cohort Study with a Mean Three-Year Follow-Up

Ömercan Sepetçi, Hasan Mehmet Tıraş, Ahmet Yiğit Kaptan, Burak Bozdoğan, Nefise Şeker, Rıdvan Acar, İbrahim Tekpınar
article en

Abstract

Background/Objectives: Parental compliance with the Pavlik harness has rarely been analyzed as a separate variable in studies of closed reduction (CR) after harness treatment. This study evaluated whether Pavlik harness use and compliance before CR are associated with CR success, avascular necrosis (AVN), and residual acetabular dysplasia (RAD) in developmental dysplasia of the hip (DDH). Methods: We retrospectively analyzed 150 hips in 87 patients who underwent CR and hip spica casting before 12 months of age between January 2020 and June 2021. Hips were grouped by pre-CR harness use: no harness (n = 66), improper use (n = 25), and proper use (n = 59). Improper use was defined as insufficient daily wear, incorrect application despite training, premature discontinuation, or continuation of the harness despite a recommendation for CR. Loss of reduction requiring further surgery was defined as failure. Clustering of hips within families was accounted for with generalized estimating equations (GEE). Results: At a mean follow-up of 38.6 ± 4.9 months, CR succeeded in 92.0% of hips. Failure rates were 20.0% with improper use, 6.1% with no harness, and 5.1% with proper use (p = 0.076). In GEE, the odds ratio (OR) for improper versus proper use was 4.48 (95% CI 0.67–29.95) and 3.28 (95% CI 0.49–22.04) after adjustment for International Hip Dysplasia Institute (IHDI) grade 4, which was strongly associated with failure (OR 15.61; 95% CI 3.92–62.23). Among successfully reduced hips, AVN (10.1%) and RAD (6.5%) did not differ significantly between groups (p = 0.128 and p = 0.121). The mean acetabular index decreased from 37.1° to 18.7° (p < 0.001). Conclusions: In this cohort, CR failure was numerically more frequent after improper Pavlik harness use, but the difference was not statistically significant and was partly explained by disease severity. No significant differences in AVN or RAD were detected. Given the small number of events, these findings should be considered hypothesis-generating, and larger studies with prospectively documented compliance are needed.

ChildrenVol. 13(12)
State Hospital (GB), Directorate of Health (IS), Şanlıurfa Mehmet Akif İnan Eğitim ve Araştırma Hastanesi (TR), Harran University (TR)
Good health and well-being
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon