A New Platform for Investigating Mechanical Contributors to Corneal Endothelial Cell Injury

PURPOSE: How different mechanical factors contribute to corneal endothelial cell (CEC) loss during eye surgeries remains poorly understood. To begin to address this gap, our objective was to develop an experimental platform capable of detecting differences in CEC viability across different contact indentation loading conditions. METHODS: Corneoscleral rims were dissected from porcine eyes within 72 h after euthanasia. Prior to indentation, endothelia were stained with viability dyes and imaged using fluorescence microscopy. Images were analyzed to determine baseline endothelial z-positions and total/injured CEC counts. Endothelia were then indented under varying conditions, with each of five control factors set to one of two levels using a design of experiments (DOE) strategy. The "high" (+1) level was hypothesized to cause greater CEC loss than the "low" (-1) level. Endothelia were re-imaged/analyzed to calculate indented z-positions and total/injured CEC counts. Total CEC loss (TCL) was defined as the change in percent CEC injury (PCI) plus percent CEC detachment (PCD). The effect of each control factor on TCL, PCI, and PCD was assessed using analysis of means (ANOM) and variance (ANOVA). Z-positions were used to measure indentation depth, and the correlation between indentation depth and TCL was evaluated. RESULTS: The high (+1) level for each control factor resulted in greater TCL, PCI, and PCD than the low (-1) level, although not all effects were statistically significant. Notably, indentation duration had a large and significant effect on CEC viability. The linear regression showed a moderate and significant correlation between indentation depth and TCL. CONCLUSION: We successfully validated that our platform detects differences in CEC viability under different indentation loading conditions. It also revealed a relationship between indentation depth and TCL, suggesting that corneal mechanical properties could serve as a predictor of CEC loss during surgery.

Authors

Institutions

Publication Details

Journal
Current Eye Research
Published
2026-11-24
DOI
https://doi.org/10.1080/02713683.2026.2746885
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A New Platform for Investigating Mechanical Contributors to Corneal Endothelial Cell Injury

Naveen Mysore, Alex J. McMullen, Mark R. Buckley, Paul D. Funkenbusch et al.
1 links
Current Eye Research
Corneal surgery and disorders
article

A New Platform for Investigating Mechanical Contributors to Corneal Endothelial Cell Injury

Naveen Mysore, Alex J. McMullen, Mark R. Buckley, Paul D. Funkenbusch, Yousuf M. Khalifa
article en

Abstract

PURPOSE: How different mechanical factors contribute to corneal endothelial cell (CEC) loss during eye surgeries remains poorly understood. To begin to address this gap, our objective was to develop an experimental platform capable of detecting differences in CEC viability across different contact indentation loading conditions. METHODS: Corneoscleral rims were dissected from porcine eyes within 72 h after euthanasia. Prior to indentation, endothelia were stained with viability dyes and imaged using fluorescence microscopy. Images were analyzed to determine baseline endothelial z-positions and total/injured CEC counts. Endothelia were then indented under varying conditions, with each of five control factors set to one of two levels using a design of experiments (DOE) strategy. The "high" (+1) level was hypothesized to cause greater CEC loss than the "low" (-1) level. Endothelia were re-imaged/analyzed to calculate indented z-positions and total/injured CEC counts. Total CEC loss (TCL) was defined as the change in percent CEC injury (PCI) plus percent CEC detachment (PCD). The effect of each control factor on TCL, PCI, and PCD was assessed using analysis of means (ANOM) and variance (ANOVA). Z-positions were used to measure indentation depth, and the correlation between indentation depth and TCL was evaluated. RESULTS: The high (+1) level for each control factor resulted in greater TCL, PCI, and PCD than the low (-1) level, although not all effects were statistically significant. Notably, indentation duration had a large and significant effect on CEC viability. The linear regression showed a moderate and significant correlation between indentation depth and TCL. CONCLUSION: We successfully validated that our platform detects differences in CEC viability under different indentation loading conditions. It also revealed a relationship between indentation depth and TCL, suggesting that corneal mechanical properties could serve as a predictor of CEC loss during surgery.

Current Eye Research
Emory University (US), University of Rochester Medical Center (US), University of Rochester (US)
U.S. Department of Energy, University of Rochester, National Institutes of Health, National Eye Institute
Good health and well-being
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon