Improvement confined to TNF when transferring an inflammation model from bolus calibration to a combined bolus and infusion protocol
Models of the human endotoxemia response are usually calibrated on one administration protocol and used to reason about others. Transfer across protocols is rarely tested. When transfer fails, it is rarely clear whether the structure cannot reproduce both protocols or the calibration failed to select a trajectory that could. A reduced model of the cytokine response was calibrated on a 1 ng/kg bolus cohort alone. For a combined protocol in which a 1 ng/kg bolus is followed by a three hour infusion, the model overpredicts plasma TNF by factors of 5.25 and 5.31 at 4 and 6 h, respectively. The overprediction persisted across all 48 solutions recovered by the search restricted to the bolus cohort within the specified tolerance of the best fit. Their predictions at 4 h spanned less than four per cent. None met the prespecified acceptance window at both hours. Five prespecified extensions, each adding one mechanism, were compared using a criterion fixed before the extensions were built. Two extensions met the criterion using parameters selected on the bolus cohort alone. Each added a loss term that depends on TNF, one acting on the transcript and one on the plasma protein. In the combined protocol, they reduced total plasma TNF prediction error from 0.45 to 0.12 and 0.13 in log units, respectively. Both undershot the 2 h peak by about a quarter. Relative to the base model, the reductions were 73.5 and 71.9 per cent in the combined protocol and 60.6 and 57.1 per cent in the 2 ng/kg bolus cohort, respectively. The improvement was therefore not specific to infusion. The available observations did not distinguish the two extensions at the evaluated time points. A third extension exposed a distinction the criterion alone cannot make. A search that used data from the combined protocol found a trajectory that met both TNF targets with a 1.4 per cent increase over that structure's best bolus calibration error. No calibration restricted to the bolus cohort recovered that trajectory. Fits of the same structure can therefore yield different transfer outcomes within a single declared tolerance. A structure can admit a trajectory that meets the targets on both protocols even when calibration on one of them does not recover it. The improvement was confined to TNF. At fixed shared parameter values, neither extension can alter predictions for IL-6 or IL-10 because the model has no pathway from the modified TNF states to either output. Reestimating the shared parameters changed the prediction error for each cytokine by less than one per cent in both evaluated cohorts. The errors remained large. At 3 h, the model predicted an IL-6 mean of 293 pg/mL against an observed mean of 1069 pg/mL. The location of an extension determines which outputs can respond. A transfer result for one output establishes nothing about transfer for the others.
Authors
- Piotr Kukier
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-24
- DOI
- https://doi.org/10.5281/zenodo.24493510
- Primary Topic
- Sepsis Diagnosis and Treatment
- Type
- preprint