Methodological errors following comparison of ultrasound and CT images of the lower jaw distraction regenerate

Objective. To justify impossibility of direct correlation between ultrasound and CT findings when monitoring mandibular distraction regenerate density in adolescents undergoing distraction osteogenesis. Material and methods. A retrospective analysis included cases of mandibular distraction osteogenesis in adolescents with mandibular micrognathia. All patients underwent routine US (1—2 times weekly) in distraction and consolidation phases, as well as elective CT (1—2 times per treatment course) to assess regenerate mineralization. Ultrasonic echogenicity was correlated with Hounsfield units (HU); statistical analysis was performed. Results. There was no direct quantitative relationship between ultrasound echogenicity and Hounsfield density. The Pearson correlation coefficient between mean US echo-density and HU was non-significant (r=0.3; p>0.05) with high interpatient variability. In several cases, US findings indicated active osteogenesis (hyperechoic signal, narrowing of distraction gap), whereas CT density remained low (HUs were significantly below cortical bone threshold). Conversely, ultrasound failed to demonstrate appropriate echogenicity in patients with relatively high HU due to acoustic shadowing from the newly formed cortical plate. Linear calibration of US echogenicity into HU yielded unsatisfactory results. Furthermore, CT scans were frequently distorted by metal artifacts from distraction hardware that precluded accurate assessment of regenerate density. Conclusion. Ultrasound imaging and CT mutually complement but do not replace each other when monitoring distraction osteogenesis. Ultrasound is valuable for dynamic follow-up in early stages (safe and highly sensitive to onset of osteogenesis), whereas CT is essential for definitive quantitative assessment of mineralization prior to device removal.

Authors

Institutions

Publication Details

Journal
Plastic Surgery and Aesthetic Medicine
Published
2026-11-24
DOI
https://doi.org/10.17116/plast.hirurgia202604251
Primary Topic
Craniofacial Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Methodological errors following comparison of ultrasound and CT images of the lower jaw distraction regenerate

Ф.Ф. Лосев, Pavel Igorevich Shapovalov
Plastic Surgery and Aesthetic Medicine
Craniofacial Disorders and Treatments
article

Methodological errors following comparison of ultrasound and CT images of the lower jaw distraction regenerate

Ф.Ф. Лосев, Pavel Igorevich Shapovalov
article en

Abstract

Objective. To justify impossibility of direct correlation between ultrasound and CT findings when monitoring mandibular distraction regenerate density in adolescents undergoing distraction osteogenesis. Material and methods. A retrospective analysis included cases of mandibular distraction osteogenesis in adolescents with mandibular micrognathia. All patients underwent routine US (1—2 times weekly) in distraction and consolidation phases, as well as elective CT (1—2 times per treatment course) to assess regenerate mineralization. Ultrasonic echogenicity was correlated with Hounsfield units (HU); statistical analysis was performed. Results. There was no direct quantitative relationship between ultrasound echogenicity and Hounsfield density. The Pearson correlation coefficient between mean US echo-density and HU was non-significant (r=0.3; p>0.05) with high interpatient variability. In several cases, US findings indicated active osteogenesis (hyperechoic signal, narrowing of distraction gap), whereas CT density remained low (HUs were significantly below cortical bone threshold). Conversely, ultrasound failed to demonstrate appropriate echogenicity in patients with relatively high HU due to acoustic shadowing from the newly formed cortical plate. Linear calibration of US echogenicity into HU yielded unsatisfactory results. Furthermore, CT scans were frequently distorted by metal artifacts from distraction hardware that precluded accurate assessment of regenerate density. Conclusion. Ultrasound imaging and CT mutually complement but do not replace each other when monitoring distraction osteogenesis. Ultrasound is valuable for dynamic follow-up in early stages (safe and highly sensitive to onset of osteogenesis), whereas CT is essential for definitive quantitative assessment of mineralization prior to device removal.

Plastic Surgery and Aesthetic Medicine(4)
National Medical Research Center of Dentistry and Maxillofacial Surgery (RU)
Good health and well-being
Craniofacial Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon