Night-deferred battery recharging in electric two-wheeler battery swapping stations: Peak-demand displacement and degradation-aware cost assessment under time-of-use tariffs

Battery swapping stations decouple the refueling of electric two-wheelers from battery recharging, yet most stations recharge returned batteries as soon as chargers become free, pushing much of the energy demand into evening hours when Indian distribution grids peak and time-of-use (TOU) tariffs are highest. This paper evaluates a night-deferred operating policy: batteries still charging at the close of the swapping day are paused, batteries returned after the point from which no further swap of the day will need them are not recharged by day at all, the station draws no grid power during the 20:00–23:00 evening peak, and the deferred energy is delivered after 23:00 through the slowest chargers the station already owns. The policy is tested on an event-driven simulation of a 100-vehicle two-wheeler station whose charger portfolio is sized by six metaheuristic algorithms, with thirty independent runs per algorithm in each regime. Night deferral reduced the mean cost per swap by 6.3–8.9% for all six algorithms (Welch’s t-test, p < 10−32; Cohen’s d = 8.6–15.4), displaced 93 kWh—35% of the daily energy—from the evening into the off-peak band, eliminated all grid draw in 20:00–23:00, and reduced the number of charger units to be installed from 68 to 49, at the price of three additional stock batteries. About half of the saving comes from the tariff and half from completing deferred batteries on low-stress slow chargers. The advantage persists when the charger-class degradation coefficients are scaled between one half and twice their base values, grows to 11.4% for a commuter day with an evening return peak, and holds for a station twice the size. The policy requires no additional chargers, storage, or grid capacity, and the simulation code and data are openly available.

Authors

Institutions

Publication Details

Journal
Energy Sources Part A Recovery Utilization and Environmental Effects
Published
2026-11-24
DOI
https://doi.org/10.1080/15567036.2026.2769065
Primary Topic
Electric Vehicles and Infrastructure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Night-deferred battery recharging in electric two-wheeler battery swapping stations: Peak-demand displacement and degradation-aware cost assessment under time-of-use tariffs

Snehal Purani, Indrajit N. Trivedi, Hardik Agravatt
Energy Sources Part A Recovery Utilization and Environmental Effects
Electric Vehicles and Infrastructure
article

Night-deferred battery recharging in electric two-wheeler battery swapping stations: Peak-demand displacement and degradation-aware cost assessment under time-of-use tariffs

Snehal Purani, Indrajit N. Trivedi, Hardik Agravatt
article en

Abstract

Battery swapping stations decouple the refueling of electric two-wheelers from battery recharging, yet most stations recharge returned batteries as soon as chargers become free, pushing much of the energy demand into evening hours when Indian distribution grids peak and time-of-use (TOU) tariffs are highest. This paper evaluates a night-deferred operating policy: batteries still charging at the close of the swapping day are paused, batteries returned after the point from which no further swap of the day will need them are not recharged by day at all, the station draws no grid power during the 20:00–23:00 evening peak, and the deferred energy is delivered after 23:00 through the slowest chargers the station already owns. The policy is tested on an event-driven simulation of a 100-vehicle two-wheeler station whose charger portfolio is sized by six metaheuristic algorithms, with thirty independent runs per algorithm in each regime. Night deferral reduced the mean cost per swap by 6.3–8.9% for all six algorithms (Welch’s t-test, p < 10−32; Cohen’s d = 8.6–15.4), displaced 93 kWh—35% of the daily energy—from the evening into the off-peak band, eliminated all grid draw in 20:00–23:00, and reduced the number of charger units to be installed from 68 to 49, at the price of three additional stock batteries. About half of the saving comes from the tariff and half from completing deferred batteries on low-stress slow chargers. The advantage persists when the charger-class degradation coefficients are scaled between one half and twice their base values, grows to 11.4% for a commuter day with an evening return peak, and holds for a station twice the size. The policy requires no additional chargers, storage, or grid capacity, and the simulation code and data are openly available.

Energy Sources Part A Recovery Utilization and Environmental EffectsVol. 48(1)
Gujarat Technological University (IN)
Affordable and clean energy, Industry, innovation and infrastructure, Climate action, Sustainable cities and communities
Electric Vehicles and Infrastructure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon