Saliency-Guided Polar Token Routing for Efficient Otoscopic Image Classification

Background/Objectives: Otoscopic image classification can support computer-aided analysis of ear conditions, but conventional Vision Transformers (ViTs) may be computationally inefficient because all image tokens are processed uniformly. This study aimed to reduce the number of active transformer tokens while retaining benchmark classification performance. Methods: We propose Saliency-Guided Polar Token Routing (SgPTR), which organizes dense visual features into radial–angular polar tokens, assigns token-wise saliency scores, and forwards only the Top-K selected tokens to the transformer encoder. SgPTR was evaluated on the Ear Imagery and Otoscopic Image datasets. To address duplicate and near-duplicate redundancy, the evaluation was repeated with a fully specified leakage-control protocol based on SHA-256 and 64-bit dHash clustering, followed by a matched 10-seed comparison against the true 48-token Polar baseline. Results: On the original Ear Imagery benchmark, SgPTR achieved 98.75% accuracy and 98.75% Macro-F1 using 12 active tokens, corresponding to a 75% reduction from the 48-token candidate representation. On the reproducibly cleaned Ear Imagery split (372 images), SgPTR with K=12 achieved 0.9118±0.0304 accuracy versus 0.9105±0.0339 for the 48-token Polar baseline, with a paired mean difference of +0.13 percentage points and a bootstrap 95% confidence interval of [−2.89,+3.42] percentage points. The Otoscopic Image Dataset remained near saturation and is therefore interpreted primarily as a ceiling-effect benchmark rather than evidence of diagnostic superiority. Conclusions: SgPTR is an efficiency-oriented token-routing framework that reduces the active sequence by 75% while retaining similar observed mean performance in the matched cleaned-data comparison; no claim of statistical equivalence, non-inferiority, or clinical generalizability is made.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-24
DOI
https://doi.org/10.3390/diagnostics16233951
Primary Topic
Advanced Neural Network Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Saliency-Guided Polar Token Routing for Efficient Otoscopic Image Classification

Saad Khalil, Youngbae Hwang, Zaka Ur Rehman
1 links
Diagnostics
Advanced Neural Network Applications
article

Saliency-Guided Polar Token Routing for Efficient Otoscopic Image Classification

Saad Khalil, Youngbae Hwang, Zaka Ur Rehman
article en

Abstract

Background/Objectives: Otoscopic image classification can support computer-aided analysis of ear conditions, but conventional Vision Transformers (ViTs) may be computationally inefficient because all image tokens are processed uniformly. This study aimed to reduce the number of active transformer tokens while retaining benchmark classification performance. Methods: We propose Saliency-Guided Polar Token Routing (SgPTR), which organizes dense visual features into radial–angular polar tokens, assigns token-wise saliency scores, and forwards only the Top-K selected tokens to the transformer encoder. SgPTR was evaluated on the Ear Imagery and Otoscopic Image datasets. To address duplicate and near-duplicate redundancy, the evaluation was repeated with a fully specified leakage-control protocol based on SHA-256 and 64-bit dHash clustering, followed by a matched 10-seed comparison against the true 48-token Polar baseline. Results: On the original Ear Imagery benchmark, SgPTR achieved 98.75% accuracy and 98.75% Macro-F1 using 12 active tokens, corresponding to a 75% reduction from the 48-token candidate representation. On the reproducibly cleaned Ear Imagery split (372 images), SgPTR with K=12 achieved 0.9118±0.0304 accuracy versus 0.9105±0.0339 for the 48-token Polar baseline, with a paired mean difference of +0.13 percentage points and a bootstrap 95% confidence interval of [−2.89,+3.42] percentage points. The Otoscopic Image Dataset remained near saturation and is therefore interpreted primarily as a ceiling-effect benchmark rather than evidence of diagnostic superiority. Conclusions: SgPTR is an efficiency-oriented token-routing framework that reduces the active sequence by 75% while retaining similar observed mean performance in the matched cleaned-data comparison; no claim of statistical equivalence, non-inferiority, or clinical generalizability is made.

DiagnosticsVol. 16(23)
Chungbuk National University (KR)
Chungbuk National University, National Research Foundation of Korea, Ministry of Science and ICT, South Korea, Institute for Information and Communications Technology Promotion
Advanced Neural Network Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon