How much of the record does a sound fault monitor need? Bounded-memory set-membership detection of sensor faults, measured against the exact oracle

A set-membership fault detector alarms when no admissible explanation of the sensor record exists. For a linear plant with bounded noise and a bounded unknown input, the exact detector keeps a polytope of unbounded description, so an embedded detector keeps a bounded outer approximation and detects later. We measure that loss. On a two-node thermal plant with one sensor, a known heat input, an unknown ambient temperature and ten sensor fault classes, a certified LP over the full history gives each certified run's exact detection time, and bounded monitors are scored against it under the same assumptions: a difference is what a monitor loses. A template polyhedron with 42 supports needs no solver, is proved sound under explicit rounding conditions and, in exact arithmetic, never later than the interval monitor. Its frozen float64 builds meet those conditions only for noise at least 4.86e-13 °C inside the bound; a revised C state meets them in full; not yet validated on fresh seeds, its PC build raises the frozen builds' alarms on all 19,200 runs of two validation blocks. On an ESP32 the C builds match their PC builds bit for bit on 5.04 million samples. On 9,600 fresh, preregistered runs the template removed 38.7% of the interval monitor's paired lag. A window LP over 256 samples with a smoothing base update removed 99.5% of that lag on a second fresh block of 9,600 runs with no missed certified event; all 7,258 alarms carried weak-duality certificates. An earlier freeze of the window failed validation on one unsolved LP; we report it and its sound replacement. No memory budget can certify the error of a sensor drift that an admissible ambient path reproduces. Seven baselines in two comparisons fixed beforehand all lagged our monitors at their memory budgets; the nearest set-based one, a strengthened interval observer, removed 8.8% of the interval monitor's lag, the template 44.2%.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-24
DOI
https://doi.org/10.5281/zenodo.24505999
Primary Topic
Fault Detection and Control Systems
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

How much of the record does a sound fault monitor need? Bounded-memory set-membership detection of sensor faults, measured against the exact oracle

Can Koç
Zenodo (CERN European Organization for Nuclear Research)
Fault Detection and Control Systems
preprint

How much of the record does a sound fault monitor need? Bounded-memory set-membership detection of sensor faults, measured against the exact oracle

Can Koç
preprint en

Abstract

A set-membership fault detector alarms when no admissible explanation of the sensor record exists. For a linear plant with bounded noise and a bounded unknown input, the exact detector keeps a polytope of unbounded description, so an embedded detector keeps a bounded outer approximation and detects later. We measure that loss. On a two-node thermal plant with one sensor, a known heat input, an unknown ambient temperature and ten sensor fault classes, a certified LP over the full history gives each certified run's exact detection time, and bounded monitors are scored against it under the same assumptions: a difference is what a monitor loses. A template polyhedron with 42 supports needs no solver, is proved sound under explicit rounding conditions and, in exact arithmetic, never later than the interval monitor. Its frozen float64 builds meet those conditions only for noise at least 4.86e-13 °C inside the bound; a revised C state meets them in full; not yet validated on fresh seeds, its PC build raises the frozen builds' alarms on all 19,200 runs of two validation blocks. On an ESP32 the C builds match their PC builds bit for bit on 5.04 million samples. On 9,600 fresh, preregistered runs the template removed 38.7% of the interval monitor's paired lag. A window LP over 256 samples with a smoothing base update removed 99.5% of that lag on a second fresh block of 9,600 runs with no missed certified event; all 7,258 alarms carried weak-duality certificates. An earlier freeze of the window failed validation on one unsolved LP; we report it and its sound replacement. No memory budget can certify the error of a sensor drift that an admissible ambient path reproduces. Seven baselines in two comparisons fixed beforehand all lagged our monitors at their memory budgets; the nearest set-based one, a strengthened interval observer, removed 8.8% of the interval monitor's lag, the template 44.2%.

Zenodo (CERN European Organization for Nuclear Research)
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon