An Interpretable Machine Learning Model for Early Prediction of Septic Shock in Intensive Care Unit Patients: The Incremental Value of Cardiac Output

Background Early identification of septic shock is critical for timely resuscitation, yet conventional vital signs such as blood pressure exhibit physiological lag during the compensatory phase. Whether advanced hemodynamic parameters confer incremental predictive value within machine learning (ML) early warning frameworks remains unquantified. Methods This retrospective cohort study used the MIMIC-IV v3.0 database. From 7384 patients with hemodynamic monitoring records, 1716 adult ICU patients contributing 16,140 hourly prediction windows were analyzed. Patients were partitioned into a development set (n = 1372) and a held-out test set (n = 344). Two nested models predicted septic shock within 6 h: a baseline model using routine variables and an enhanced model adding cardiac output (CO), cardiac index (CI), stroke volume index (SVI), and systemic vascular resistance index (SVRI). XGBoost was the primary classifier. Patient-level cross-validation and clustered bootstrap evaluated discrimination, calibration, and clinical utility, while SHAP and ablation assessed feature contributions. Results The enhanced model consistently outperformed the baseline across four algorithms. With XGBoost, cross-validated AUROC improved from 0.862 (95% CI 0.847-0.877) to 0.881 (0.867-0.894), a gain of 0.018 (0.010-0.027; DeLong p = 3.22 × 10 −11). Sensitivity increased from 0.249 to 0.316 and F1 from 0.335 to 0.388. Held-out AUROC was 0.819 versus 0.844 (p = 2.06 × 10 −6). Calibration was comparable, and the enhanced model provided greater net benefit at threshold probabilities of 0.01-0.49. SHAP ranked CO second only to lactate; removing CO reduced AUROC by 0.017 (0.008-0.024), whereas removing the derived indices had negligible effects. Conclusions Incorporating cardiac output into routine monitoring models provides robust incremental value for early septic shock prediction. CO captures circulatory compromise masked by compensatory normotension and may support risk-stratified ICU surveillance.

Authors

Institutions

Publication Details

Journal
Journal of Intensive Care Medicine
Published
2026-11-24
DOI
https://doi.org/10.1177/08850666261503535
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Interpretable Machine Learning Model for Early Prediction of Septic Shock in Intensive Care Unit Patients: The Incremental Value of Cardiac Output

Yangming Yue, Yulu Xu, 刘三朝, Wenyu Ye et al.
3 links
Journal of Intensive Care Medicine
Sepsis Diagnosis and Treatment
article

An Interpretable Machine Learning Model for Early Prediction of Septic Shock in Intensive Care Unit Patients: The Incremental Value of Cardiac Output

Yangming Yue, Yulu Xu, 刘三朝, Wenyu Ye, Ke Xiao, Shengwen Luo, Ye Li
article en

Abstract

Background Early identification of septic shock is critical for timely resuscitation, yet conventional vital signs such as blood pressure exhibit physiological lag during the compensatory phase. Whether advanced hemodynamic parameters confer incremental predictive value within machine learning (ML) early warning frameworks remains unquantified. Methods This retrospective cohort study used the MIMIC-IV v3.0 database. From 7384 patients with hemodynamic monitoring records, 1716 adult ICU patients contributing 16,140 hourly prediction windows were analyzed. Patients were partitioned into a development set (n = 1372) and a held-out test set (n = 344). Two nested models predicted septic shock within 6 h: a baseline model using routine variables and an enhanced model adding cardiac output (CO), cardiac index (CI), stroke volume index (SVI), and systemic vascular resistance index (SVRI). XGBoost was the primary classifier. Patient-level cross-validation and clustered bootstrap evaluated discrimination, calibration, and clinical utility, while SHAP and ablation assessed feature contributions. Results The enhanced model consistently outperformed the baseline across four algorithms. With XGBoost, cross-validated AUROC improved from 0.862 (95% CI 0.847-0.877) to 0.881 (0.867-0.894), a gain of 0.018 (0.010-0.027; DeLong p = 3.22 × 10 −11). Sensitivity increased from 0.249 to 0.316 and F1 from 0.335 to 0.388. Held-out AUROC was 0.819 versus 0.844 (p = 2.06 × 10 −6). Calibration was comparable, and the enhanced model provided greater net benefit at threshold probabilities of 0.01-0.49. SHAP ranked CO second only to lactate; removing CO reduced AUROC by 0.017 (0.008-0.024), whereas removing the derived indices had negligible effects. Conclusions Incorporating cardiac output into routine monitoring models provides robust incremental value for early septic shock prediction. CO captures circulatory compromise masked by compensatory normotension and may support risk-stratified ICU surveillance.

Journal of Intensive Care Medicine
Chinese Academy of Sciences (CN), Shenzhen Institutes of Advanced Technology (CN), Mindray (China) (CN), Zhejiang University (CN)
Good health and well-being
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon