Multimodal reflection contrast mechanism driven by coupled resonators for glucose concentration-dependent resonance redistributed sensing
A reflection-based multimodal resonance contrast mechanism driven by coupled resonators is presented for RF glucose concentration sensing measurements. The proposed sensor employs a metasurface-backed corrugated patch architecture integrating a central radiating element with concentric circular resonators to enable strong inter-mode coupling. This configuration supports multiple resonant modes in the reflection response, forming the basis for multimodal sensing. Compared to conventional single-resonance approaches, the proposed mechanism exploits the relative evolution of resonances, leading to enhanced sensitivity, and improved detection resolution. The sensor demonstrates dual-frequency operation with near-linear response characteristics over the tested concentration range. An equivalent coupled-resonator model is further employed to provide physical insight into the observed multimodal behavior. The complementary metasurface ground introduces distributed reactive loading that strengthens near-field confinement and increases electromagnetic interaction with the analyte placed above the sensing region. The overall dimensions of the sensor are (34 mm × 20 mm) while the main middle sensing region is just 20 mm making it a compact design. Variations in glucose concentration modify the effective permittivity, leading to measurable shifts in resonant frequencies, changes in reflection depth, and controlled variation in resonance separation. At the first resonance frequency, a highly noticeable shift of 90 MHz and at the second frequency a shift of 170 MHz has been obtained between glucose concentrations 75–150 mg/dL (a clinical diabetic range). The proposed sensor has further obtained a low minimum experimentally detectable glucose concentration of < 0.05 wt.%. These multimodal reflection characteristics provide an improved sensing metric compared to single-parameter frequency tracking. Measured reflection analysis demonstrates high sensitivity across both resonant bands, with clear and repeatable resonance displacement corresponding to incremental glucose concentration changes. The dual-band operation enables enhanced detection reliability and expanded dynamic range. Owing to its compact geometry, strong field localization, the proposed sensor provides a promising platform for high-sensitivity RF-based glucose monitoring and other dielectric sensing applications.
Authors
- Allah Dekama Jara (ORCID: https://orcid.org/0000-0002-2075-4825)
- Abhishek Kandwal (ORCID: https://orcid.org/0000-0002-5106-3680)
- Tanya Sood (ORCID: https://orcid.org/0000-0001-7900-3551)
- Ali M. Almuhlafi (ORCID: https://orcid.org/0000-0002-9184-9936)
- Suresh Kumar (ORCID: https://orcid.org/0000-0002-3679-1049)
- Hamsakutty Vettikalladi (ORCID: https://orcid.org/0000-0002-8645-4235)
- Pawan Kumar
- Arjun Kumar
- Hamsakutty Vettikalladi
- Rohit Jasortia
Institutions
- University of Liverpool (GB)
- Maharishi Markandeshwar University, Mullana (IN)
- King Saud University (SA)
- Shoolini University (IN)
- Xi’an Jiaotong-Liverpool University (CN)
- Adama Science and Technology University (ET)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-24
- DOI
- https://doi.org/10.1038/s41598-026-72254-y
- Primary Topic
- Microwave and Dielectric Measurement Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- King Saud University
- Xi’an Jiaotong-Liverpool University