Multimodal reflection contrast mechanism driven by coupled resonators for glucose concentration-dependent resonance redistributed sensing

A reflection-based multimodal resonance contrast mechanism driven by coupled resonators is presented for RF glucose concentration sensing measurements. The proposed sensor employs a metasurface-backed corrugated patch architecture integrating a central radiating element with concentric circular resonators to enable strong inter-mode coupling. This configuration supports multiple resonant modes in the reflection response, forming the basis for multimodal sensing. Compared to conventional single-resonance approaches, the proposed mechanism exploits the relative evolution of resonances, leading to enhanced sensitivity, and improved detection resolution. The sensor demonstrates dual-frequency operation with near-linear response characteristics over the tested concentration range. An equivalent coupled-resonator model is further employed to provide physical insight into the observed multimodal behavior. The complementary metasurface ground introduces distributed reactive loading that strengthens near-field confinement and increases electromagnetic interaction with the analyte placed above the sensing region. The overall dimensions of the sensor are (34 mm × 20 mm) while the main middle sensing region is just 20 mm making it a compact design. Variations in glucose concentration modify the effective permittivity, leading to measurable shifts in resonant frequencies, changes in reflection depth, and controlled variation in resonance separation. At the first resonance frequency, a highly noticeable shift of 90 MHz and at the second frequency a shift of 170 MHz has been obtained between glucose concentrations 75–150 mg/dL (a clinical diabetic range). The proposed sensor has further obtained a low minimum experimentally detectable glucose concentration of < 0.05 wt.%. These multimodal reflection characteristics provide an improved sensing metric compared to single-parameter frequency tracking. Measured reflection analysis demonstrates high sensitivity across both resonant bands, with clear and repeatable resonance displacement corresponding to incremental glucose concentration changes. The dual-band operation enables enhanced detection reliability and expanded dynamic range. Owing to its compact geometry, strong field localization, the proposed sensor provides a promising platform for high-sensitivity RF-based glucose monitoring and other dielectric sensing applications.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-24
DOI
https://doi.org/10.1038/s41598-026-72254-y
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multimodal reflection contrast mechanism driven by coupled resonators for glucose concentration-dependent resonance redistributed sensing

Allah Dekama Jara, Abhishek Kandwal, Tanya Sood, Ali M. Almuhlafi et al.
3 links
Scientific Reports
Microwave and Dielectric Measurement Techniques
article

Multimodal reflection contrast mechanism driven by coupled resonators for glucose concentration-dependent resonance redistributed sensing

Allah Dekama Jara, Abhishek Kandwal, Tanya Sood, Ali M. Almuhlafi, Suresh Kumar, Hamsakutty Vettikalladi, Pawan Kumar, Arjun Kumar, Hamsakutty Vettikalladi, Rohit Jasortia
article en

Abstract

A reflection-based multimodal resonance contrast mechanism driven by coupled resonators is presented for RF glucose concentration sensing measurements. The proposed sensor employs a metasurface-backed corrugated patch architecture integrating a central radiating element with concentric circular resonators to enable strong inter-mode coupling. This configuration supports multiple resonant modes in the reflection response, forming the basis for multimodal sensing. Compared to conventional single-resonance approaches, the proposed mechanism exploits the relative evolution of resonances, leading to enhanced sensitivity, and improved detection resolution. The sensor demonstrates dual-frequency operation with near-linear response characteristics over the tested concentration range. An equivalent coupled-resonator model is further employed to provide physical insight into the observed multimodal behavior. The complementary metasurface ground introduces distributed reactive loading that strengthens near-field confinement and increases electromagnetic interaction with the analyte placed above the sensing region. The overall dimensions of the sensor are (34 mm × 20 mm) while the main middle sensing region is just 20 mm making it a compact design. Variations in glucose concentration modify the effective permittivity, leading to measurable shifts in resonant frequencies, changes in reflection depth, and controlled variation in resonance separation. At the first resonance frequency, a highly noticeable shift of 90 MHz and at the second frequency a shift of 170 MHz has been obtained between glucose concentrations 75–150 mg/dL (a clinical diabetic range). The proposed sensor has further obtained a low minimum experimentally detectable glucose concentration of < 0.05 wt.%. These multimodal reflection characteristics provide an improved sensing metric compared to single-parameter frequency tracking. Measured reflection analysis demonstrates high sensitivity across both resonant bands, with clear and repeatable resonance displacement corresponding to incremental glucose concentration changes. The dual-band operation enables enhanced detection reliability and expanded dynamic range. Owing to its compact geometry, strong field localization, the proposed sensor provides a promising platform for high-sensitivity RF-based glucose monitoring and other dielectric sensing applications.

Scientific ReportsVol. 16(1)
University of Liverpool (GB), Maharishi Markandeshwar University, Mullana (IN), King Saud University (SA), Shoolini University (IN), Xi’an Jiaotong-Liverpool University (CN), Adama Science and Technology University (ET)
King Saud University, Xi’an Jiaotong-Liverpool University
Good health and well-being
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon