Complex cataract extraction in a highly myopic eye with an iris-fixated phakic intraocular lens after retinal detachment repair: a case report

Background Cataract extraction after explantation of an iris-fixated phakic intraocular lens is technically demanding. The coexistence of previous retinal detachment repair, anterior chamber silicone oil, posterior synechiae, a fibrotic pupillary membrane, and reduced endothelial cell density creates interacting risks that are not commonly addressed together. We report a stepwise surgical approach to this uncommon clinical scenario. Case presentation: A 35-year-old man with high myopia and previous retinal detachment repair presented with progressive visual loss in the left eye. Best-corrected visual acuity was 1.3 logMAR. Examination showed a complicated cataract, an Artiflex iris-fixated phakic intraocular lens, silicone oil droplets in the anterior chamber, posterior synechiae, a large peripheral iridectomy, and an attached retina. Endothelial cell density was 1,500 cells/mm2. Surgery comprised ophthalmic viscosurgical device-assisted chamber stabilization, synechiolysis, controlled disenclavation and explantation of the phakic lens, peeling of a fibrotic pupillary membrane, mechanical pupil expansion, continuous curvilinear capsulorhexis, bimanual irrigation-aspiration of the soft crystalline lens, and in-the-bag posterior chamber intraocular lens implantation. Best-corrected visual acuity improved to 0.22 logMAR, and the retina remained attached without corneal decompensation, pressure elevation, or other reported complications during 12 months of follow-up. Conclusions In a highly myopic eye with prior retinal surgery and multiple anterior segment risk factors, deliberate sequencing of iris-fixated phakic intraocular lens explantation, pupil reconstruction, low-energy cataract extraction, and endothelial protection can permit a favorable anatomical and visual outcome. The principal lesson is the need to tailor the operative sequence to the interacting risks rather than treating each factor in isolation.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-11-24
DOI
https://doi.org/10.3389/fmed.2026.1942506
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Complex cataract extraction in a highly myopic eye with an iris-fixated phakic intraocular lens after retinal detachment repair: a case report

Mihnea Munteanu, Cosmin Roşca, Cristina Pac
Frontiers in Medicine
Intraocular Surgery and Lenses
article

Complex cataract extraction in a highly myopic eye with an iris-fixated phakic intraocular lens after retinal detachment repair: a case report

Mihnea Munteanu, Cosmin Roşca, Cristina Pac
article en

Abstract

Background Cataract extraction after explantation of an iris-fixated phakic intraocular lens is technically demanding. The coexistence of previous retinal detachment repair, anterior chamber silicone oil, posterior synechiae, a fibrotic pupillary membrane, and reduced endothelial cell density creates interacting risks that are not commonly addressed together. We report a stepwise surgical approach to this uncommon clinical scenario. Case presentation: A 35-year-old man with high myopia and previous retinal detachment repair presented with progressive visual loss in the left eye. Best-corrected visual acuity was 1.3 logMAR. Examination showed a complicated cataract, an Artiflex iris-fixated phakic intraocular lens, silicone oil droplets in the anterior chamber, posterior synechiae, a large peripheral iridectomy, and an attached retina. Endothelial cell density was 1,500 cells/mm2. Surgery comprised ophthalmic viscosurgical device-assisted chamber stabilization, synechiolysis, controlled disenclavation and explantation of the phakic lens, peeling of a fibrotic pupillary membrane, mechanical pupil expansion, continuous curvilinear capsulorhexis, bimanual irrigation-aspiration of the soft crystalline lens, and in-the-bag posterior chamber intraocular lens implantation. Best-corrected visual acuity improved to 0.22 logMAR, and the retina remained attached without corneal decompensation, pressure elevation, or other reported complications during 12 months of follow-up. Conclusions In a highly myopic eye with prior retinal surgery and multiple anterior segment risk factors, deliberate sequencing of iris-fixated phakic intraocular lens explantation, pupil reconstruction, low-energy cataract extraction, and endothelial protection can permit a favorable anatomical and visual outcome. The principal lesson is the need to tailor the operative sequence to the interacting risks rather than treating each factor in isolation.

Frontiers in MedicineVol. 13
Victor Babeș University of Medicine and Pharmacy Timișoara (RO)
Good health and well-being
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Complex cataract extraction in a highly myopic eye with an iris-fixated phakic intraocular lens after retinal detachment repair: a case report — Mihnea Munteanu, Cosmin Roşca, et al. · Frontiers in Medicine (2026) | TGRS Research Map | TGRS