A multi‐resolution SWIN transformer framework regularized by white matter time‐intensity curve for brain dynamic contrast‐enhanced MR image registration

BACKGROUND: Deep learning-based registration methods are often computationally intensive and struggle with dynamic contrast-enhanced (DCE) images, as they cannot effectively distinguish motion artifacts from contrast-induced intensity variations, leading to unreliable physiological parameter estimation. PURPOSE: To develop a novel registration framework (TIC-SViT) based on a multi-resolution SWIN transformer architecture that exploits the inherent smoothness of tissue time-intensity curves (TICs). METHODS: A retrospective study was conducted on DCE-MRI brain data from 59 subjects, acquired using a 3.0 T scanner with a T1-weighted spoiled gradient echo sequence. The dataset was randomly split into training (n = 4956), validation (n = 1180), and testing (n = 59) pairs. Model performance was assessed in terms of computational efficiency, registration accuracy, and clinical relevance. Comparative experiments were conducted against four representative registration approaches: the traditional optimization-based method ANTs, a CNN-based deep learning model, the groupwise multi-resolution framework (GWMS), and the transformer-based C2FViT framework. Computational efficiency was assessed by comparing parameter count, training time, and testing time per DCE-MRI case. Registration accuracy was quantified using Dice coefficient (DC) and the 95th percentile Hausdorff distance (HD95) across white matter, gray matter, and cerebrospinal fluid. In addition, the temporal smoothness of TICs in arterial, venous, and white matter regions was evaluated using root mean squared error (RMSE). Clinical relevance was examined by comparing the quality of DCE-derived parameter maps generated from different registration methods. RESULTS: The proposed TIC-SViT model achieved a comparable parameter count (12.2 M, compared with 11.7, 9.5, and 12.4 M for CNN, GWMS, and C2FViT, respectively), the shortest training time and competitive testing speed (775 s and 11.7 s per case, compared with 1142 and 52.6 s for CNN, 1440 and 8.9 s for GWMS, 857 and 39.4 s for C2FViT, and 159.3 s for ANTs, which does not require training). It also produced the lowest RMSE values for TICs in artery (0.12), venous (0.14), and white matter (0.15) regions among all compared methods. In terms of global registration accuracy, C2FViT achieved the best performance, with DC values of 0.98, 0.97, and 0.82 for white matter, gray matter and cerebrospinal fluid, respectively, and the lowest HD95 value (9.5). The proposed TIC-SViT achieved the second best performance, with DC values of 0.97, 0.96, and 0.81, and HD95 of 10.2. CONCLUSIONS: The proposed method demonstrated registration accuracy comparable to that of state-of-the-art methods, but with significant improvement in computational efficiency.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-11-24
DOI
https://doi.org/10.1002/mp.70771
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A multi‐resolution SWIN transformer framework regularized by white matter time‐intensity curve for brain dynamic contrast‐enhanced MR image registration

Lei Lei, Jinhong Tao, Yinglong He, Xin Zhang et al.
2 links
Medical Physics
Medical Image Segmentation Techniques
article

A multi‐resolution SWIN transformer framework regularized by white matter time‐intensity curve for brain dynamic contrast‐enhanced MR image registration

Lei Lei, Jinhong Tao, Yinglong He, Xin Zhang, Zhong Zheng, Shuyuan Liu, Feng Xi, Zhengyang Zhu
article en

Abstract

BACKGROUND: Deep learning-based registration methods are often computationally intensive and struggle with dynamic contrast-enhanced (DCE) images, as they cannot effectively distinguish motion artifacts from contrast-induced intensity variations, leading to unreliable physiological parameter estimation. PURPOSE: To develop a novel registration framework (TIC-SViT) based on a multi-resolution SWIN transformer architecture that exploits the inherent smoothness of tissue time-intensity curves (TICs). METHODS: A retrospective study was conducted on DCE-MRI brain data from 59 subjects, acquired using a 3.0 T scanner with a T1-weighted spoiled gradient echo sequence. The dataset was randomly split into training (n = 4956), validation (n = 1180), and testing (n = 59) pairs. Model performance was assessed in terms of computational efficiency, registration accuracy, and clinical relevance. Comparative experiments were conducted against four representative registration approaches: the traditional optimization-based method ANTs, a CNN-based deep learning model, the groupwise multi-resolution framework (GWMS), and the transformer-based C2FViT framework. Computational efficiency was assessed by comparing parameter count, training time, and testing time per DCE-MRI case. Registration accuracy was quantified using Dice coefficient (DC) and the 95th percentile Hausdorff distance (HD95) across white matter, gray matter, and cerebrospinal fluid. In addition, the temporal smoothness of TICs in arterial, venous, and white matter regions was evaluated using root mean squared error (RMSE). Clinical relevance was examined by comparing the quality of DCE-derived parameter maps generated from different registration methods. RESULTS: The proposed TIC-SViT model achieved a comparable parameter count (12.2 M, compared with 11.7, 9.5, and 12.4 M for CNN, GWMS, and C2FViT, respectively), the shortest training time and competitive testing speed (775 s and 11.7 s per case, compared with 1142 and 52.6 s for CNN, 1440 and 8.9 s for GWMS, 857 and 39.4 s for C2FViT, and 159.3 s for ANTs, which does not require training). It also produced the lowest RMSE values for TICs in artery (0.12), venous (0.14), and white matter (0.15) regions among all compared methods. In terms of global registration accuracy, C2FViT achieved the best performance, with DC values of 0.98, 0.97, and 0.82 for white matter, gray matter and cerebrospinal fluid, respectively, and the lowest HD95 value (9.5). The proposed TIC-SViT achieved the second best performance, with DC values of 0.97, 0.96, and 0.81, and HD95 of 10.2. CONCLUSIONS: The proposed method demonstrated registration accuracy comparable to that of state-of-the-art methods, but with significant improvement in computational efficiency.

Medical PhysicsVol. 53(12)
University of Surrey (GB), Nanjing University of Science and Technology (CN), Jiaxing University (CN), Nanjing Drum Tower Hospital (CN), Jingning County People's Hospital (CN), Nanjing University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Zhejiang Province
Good health and well-being
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon