ZC Potentiostat: A Portable, Low-Cost, Edge-AI-Enabled Electrochemical Analyzer for Rapid Lead Screening in Glazed Pottery Foodware

Chemistry, materials science, and biomedical sciences have been interested in potentiostats to determine various parameters in electrochemical experiments. This study aimed to implement a portable, low-cost, multi-channel electrochemical analyzer integrated with an on-device machine-learning classifier that gives a binary verdict in real time, displayed in its progressive web application. Scans are stored in a cloud database, from which the training data were exported; the model can be retrained as more scans are collected. Its operating techniques are cyclic voltammetry, linear sweep voltammetry with an anodic stripping option, and chronoamperometry in a potential range of ± 1.5 V for three different current ranges from ± 50 µA to ± 1.5 mA, with one channel assigned for each current range. The analyzer costs only $43. It was validated on a redox reaction using the ferricyanide couple, then on our main application: an anodic stripping binary classifier for lead leached from glazed pottery foodware. All experiments were conducted against a commercial potentiostat. The lead calibration was linear (R² = 0.99) with a limit of detection of 0.79 mg L − 1 in the leachate against the 4 mg L − 1 limit for Category 2 ceramic articles. As a proof-of-concept, we conducted 30 leave-one-out cross-validation runs on balanced datasets of 22 scans, and it distinguished safe from unsafe scans with 88.0% ± 2.2% accuracy against a 50% baseline. Four leachates were analyzed by atomic absorption spectrometry, and the safe/unsafe classification agreed with the commercial instrument’s calibrated result and with AAS.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-24
DOI
https://doi.org/10.21203/rs.3.rs-11494188/v1
Primary Topic
Electrochemical Analysis and Applications
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

ZC Potentiostat: A Portable, Low-Cost, Edge-AI-Enabled Electrochemical Analyzer for Rapid Lead Screening in Glazed Pottery Foodware

Ahmed S. Abd-Rabou, Rabeay Y. A. Hassan, Omar Ramadan, Yomnah A. Hassan
Research Square
Electrochemical Analysis and Applications
preprint

ZC Potentiostat: A Portable, Low-Cost, Edge-AI-Enabled Electrochemical Analyzer for Rapid Lead Screening in Glazed Pottery Foodware

Ahmed S. Abd-Rabou, Rabeay Y. A. Hassan, Omar Ramadan, Yomnah A. Hassan
preprint en

Abstract

Chemistry, materials science, and biomedical sciences have been interested in potentiostats to determine various parameters in electrochemical experiments. This study aimed to implement a portable, low-cost, multi-channel electrochemical analyzer integrated with an on-device machine-learning classifier that gives a binary verdict in real time, displayed in its progressive web application. Scans are stored in a cloud database, from which the training data were exported; the model can be retrained as more scans are collected. Its operating techniques are cyclic voltammetry, linear sweep voltammetry with an anodic stripping option, and chronoamperometry in a potential range of ± 1.5 V for three different current ranges from ± 50 µA to ± 1.5 mA, with one channel assigned for each current range. The analyzer costs only $43. It was validated on a redox reaction using the ferricyanide couple, then on our main application: an anodic stripping binary classifier for lead leached from glazed pottery foodware. All experiments were conducted against a commercial potentiostat. The lead calibration was linear (R² = 0.99) with a limit of detection of 0.79 mg L − 1 in the leachate against the 4 mg L − 1 limit for Category 2 ceramic articles. As a proof-of-concept, we conducted 30 leave-one-out cross-validation runs on balanced datasets of 22 scans, and it distinguished safe from unsafe scans with 88.0% ± 2.2% accuracy against a 50% baseline. Four leachates were analyzed by atomic absorption spectrometry, and the safe/unsafe classification agreed with the commercial instrument’s calibrated result and with AAS.

Research Square
Zewail City of Science and Technology (EG)
Zewail City of Science and Technology
Responsible consumption and production
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
ZC Potentiostat: A Portable, Low-Cost, Edge-AI-Enabled Electrochemical Analyzer for Rapid Lead Screening in Glazed Pottery Foodware — Ahmed S. Abd-Rabou, Rabeay Y. A. Hassan, et al. · Research Square (2026) | TGRS Research Map | TGRS