Episode calibrated thermal residual monitoring for battery fast charging protection

Temperature-sensor faults can delay protective current reduction during battery fast charging, while unnecessary alarms reduce charge delivery. This study evaluates whole-episode calibration of thermal residual monitors in a reproducible Python simulation. A two-node virtual cell represents a 50 A h battery during a 1200s charging opportunity. Training, calibration, and testing use separate virtual cells. Raw, mean-centered, linear, and quadratic predictors are compared with an identified physical model, repeated calibration draws, alternative fallback policies, and independent parameter shifts. In the original nominal test, quadratic correction achieved a healthy filtered residual root mean square error of 0.396 °C. An identified physical predictor achieved 0.441 °C, with a gradual-bias detection delay of 73.61 s compared with 67.44 s for the original quadratic monitor. Across 20 independent training and calibration repetitions, quadratic healthy-episode alarms averaged 4.84% and ranged from 3.00% to 7.50%. Under simultaneous negative sensor bias and cooling loss, a prediction-independent 75 A fallback increased mean delivered charge from 22.960 to 33.049 A h relative to a 25 A cap, with zero observed 45 °C exceedances in both 400-cell comparisons. Under the combined parameter shift, recalibration reduced the healthy-episode false-alarm rate from 100% (400/400) to 4.75% (19/400). After recalibration, only 22.25% (89/400) of gradual negative-bias episodes were detected after fault onset. A separate public-data check used ten measured 1C charging records from one 2.9 A h cell. The two-node predictor achieved a surface-temperature root mean square error of 0.293 °C on five held-out records, without resolving a distinct fast internal thermal mode. The results favor adequate physical calibration and joint assessment of detection, intervention cost, and calibration transfer. High-rate closed-loop protection remains supported by simulation.

Authors

Institutions

Publication Details

Journal
Frontiers in Mechanical Engineering
Published
2026-11-24
DOI
https://doi.org/10.3389/fmech.2026.2035718
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Episode calibrated thermal residual monitoring for battery fast charging protection

Chunhui Liu, Li Mingtao
Frontiers in Mechanical Engineering
Battery Modeling and Management
article

Episode calibrated thermal residual monitoring for battery fast charging protection

Chunhui Liu, Li Mingtao
article en

Abstract

Temperature-sensor faults can delay protective current reduction during battery fast charging, while unnecessary alarms reduce charge delivery. This study evaluates whole-episode calibration of thermal residual monitors in a reproducible Python simulation. A two-node virtual cell represents a 50 A h battery during a 1200s charging opportunity. Training, calibration, and testing use separate virtual cells. Raw, mean-centered, linear, and quadratic predictors are compared with an identified physical model, repeated calibration draws, alternative fallback policies, and independent parameter shifts. In the original nominal test, quadratic correction achieved a healthy filtered residual root mean square error of 0.396 °C. An identified physical predictor achieved 0.441 °C, with a gradual-bias detection delay of 73.61 s compared with 67.44 s for the original quadratic monitor. Across 20 independent training and calibration repetitions, quadratic healthy-episode alarms averaged 4.84% and ranged from 3.00% to 7.50%. Under simultaneous negative sensor bias and cooling loss, a prediction-independent 75 A fallback increased mean delivered charge from 22.960 to 33.049 A h relative to a 25 A cap, with zero observed 45 °C exceedances in both 400-cell comparisons. Under the combined parameter shift, recalibration reduced the healthy-episode false-alarm rate from 100% (400/400) to 4.75% (19/400). After recalibration, only 22.25% (89/400) of gradual negative-bias episodes were detected after fault onset. A separate public-data check used ten measured 1C charging records from one 2.9 A h cell. The two-node predictor achieved a surface-temperature root mean square error of 0.293 °C on five held-out records, without resolving a distinct fast internal thermal mode. The results favor adequate physical calibration and joint assessment of detection, intervention cost, and calibration transfer. High-rate closed-loop protection remains supported by simulation.

Frontiers in Mechanical EngineeringVol. 12
Shandong Huayu University of Technology (CN)
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.