Micro-computed tomography enables in vitro 3D quantification of denture adhesive behavior at denture-mucosa interface

Introduction Removable dentures remain an important rehabilitation option for edentulous patients, with performance critically dependent on geometric adaptation between the denture base and underlying tissue. Interfacial gaps concentrate chewing stress, contributing to discomfort and reduced stability. Poly (methyl vinyl ether-co-maleic acid) (PVM/MA)-based denture adhesives hydrate to form a viscoelastic layer that occupies this mismatch and cushions the denture–mucosa interface. However, conventional retention tests and two-dimensional imaging cannot resolve how adhesive distributes across a full denture interface. Methods Here, we introduce a micro-computed tomography (micro-CT) workflow for non-destructive three-dimensional visualization and quantitative characterization of the denture–mucosa interface. Using polyethylene jaw replicas under simulated 40 N bite force, dentures were imaged before and after adhesive application. Results Adhesive-mediated filling of interfacial discontinuities reduced void volume by 55.22% (mandibular) and 38.85% (maxillary). Effective contact area increased from 2.66 cm 2 [95% CI: 2.10, 3.23] to 17.23 cm 2 [95% CI: 16.32, 18.15], (p = 1.33 × 10 −7) on the mandibular dentures and from 7.48 cm 2 [95% CI: 5.46, 9.51] to 38.79 cm 2 [95% CI: 33.47, 44.11], (p = 1.83 × 10 −5) on the maxillary dentures, indicating a transition from localized to continuous adhesive-mediated contact. Discussion This work demonstrates that micro-CT directly links adhesive distribution to interfacial geometry, providing a quantitative framework for correlating adhesive formulation, interfacial morphology, and prosthetic adaptation.

Authors

Institutions

Publication Details

Journal
Frontiers in Biomaterials Science
Published
2026-11-24
DOI
https://doi.org/10.3389/fbiom.2026.1932370
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Micro-computed tomography enables in vitro 3D quantification of denture adhesive behavior at denture-mucosa interface

Deniz Tanil Yucesoy, Roxane Bonithon, Behrad Mahmoodi, Marta Roldo et al.
Frontiers in Biomaterials Science
Dental materials and restorations
article

Micro-computed tomography enables in vitro 3D quantification of denture adhesive behavior at denture-mucosa interface

Deniz Tanil Yucesoy, Roxane Bonithon, Behrad Mahmoodi, Marta Roldo, Nodoka Iwasaki, Robert P. Howlin, Katerina Karali, Amantle Balang
article en

Abstract

Introduction Removable dentures remain an important rehabilitation option for edentulous patients, with performance critically dependent on geometric adaptation between the denture base and underlying tissue. Interfacial gaps concentrate chewing stress, contributing to discomfort and reduced stability. Poly (methyl vinyl ether-co-maleic acid) (PVM/MA)-based denture adhesives hydrate to form a viscoelastic layer that occupies this mismatch and cushions the denture–mucosa interface. However, conventional retention tests and two-dimensional imaging cannot resolve how adhesive distributes across a full denture interface. Methods Here, we introduce a micro-computed tomography (micro-CT) workflow for non-destructive three-dimensional visualization and quantitative characterization of the denture–mucosa interface. Using polyethylene jaw replicas under simulated 40 N bite force, dentures were imaged before and after adhesive application. Results Adhesive-mediated filling of interfacial discontinuities reduced void volume by 55.22% (mandibular) and 38.85% (maxillary). Effective contact area increased from 2.66 cm 2 [95% CI: 2.10, 3.23] to 17.23 cm 2 [95% CI: 16.32, 18.15], (p = 1.33 × 10 −7) on the mandibular dentures and from 7.48 cm 2 [95% CI: 5.46, 9.51] to 38.79 cm 2 [95% CI: 33.47, 44.11], (p = 1.83 × 10 −5) on the maxillary dentures, indicating a transition from localized to continuous adhesive-mediated contact. Discussion This work demonstrates that micro-CT directly links adhesive distribution to interfacial geometry, providing a quantitative framework for correlating adhesive formulation, interfacial morphology, and prosthetic adaptation.

Frontiers in Biomaterials ScienceVol. 5
Haleon (United Kingdom) (GB), University of Portsmouth (GB)
Haleon
Good health and well-being
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon