Off-design thermoeconomic assessment of low-GWP replacement in R245fa ORC systems coupled with reservoir degradation

A coupled thermo–hydro–mechanical (THM) reservoir model of the Chingshui geothermal field was integrated with an organic Rankine cycle (ORC) model to assess long-term system performance under progressive reservoir cooling. A single-stage axial turbo-expander originally designed for R245fa was characterized through three-dimensional computational fluid dynamics simulations, and the resulting dataset trained an artificial neural network surrogate for predicting off-design mass flow rate, isentropic efficiency, and shaft power. Annually resolved reservoir temperatures from the THM model were sequentially introduced into the ORC model to evaluate off-design performance under pinch-temperature constraints over the plant lifetime. The feasibility of operating the same R245fa-designed hardware with the low-global-warming-potential (low-GWP) refrigerant R1234ze(Z) was assessed under identical configurations and degrading heat-source conditions. Over 30 years at 30 kg/s geothermal mass flow rate, both fluids followed comparable degradation trends, with the first-law efficiency of the total system declining by 18.19% for R245fa and 18.52% for R1234ze(Z). Despite comparable thermodynamic behavior, R1234ze(Z) achieved a lower levelized cost of electricity than R245fa by the 30th year. R1234ze(Z) delivered a turbo-expander total-to-static isentropic efficiency 1.84 percentage points higher than R245fa at 30 kg/s in the 30th year, corresponding to a relative difference of 2.26%, attributable to its lower Mach number. R1234ze(Z) is therefore identified as a promising low-GWP candidate for R245fa-designed geothermal ORC systems, although its direct drop-in feasibility without hardware modification remains subject to experimental verification. These findings highlight the importance of evaluating low-GWP refrigerants based on long-term off-design adaptability of existing hardware rather than design-condition performance alone.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-11-24
DOI
https://doi.org/10.1016/j.egyr.2026.109963
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Off-design thermoeconomic assessment of low-GWP replacement in R245fa ORC systems coupled with reservoir degradation

Rajiv Kamaraj, Jui-Ching Hsieh, Yu-Cheng Lin, Yi-Chen Li
Energy Reports
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Off-design thermoeconomic assessment of low-GWP replacement in R245fa ORC systems coupled with reservoir degradation

Rajiv Kamaraj, Jui-Ching Hsieh, Yu-Cheng Lin, Yi-Chen Li
article en

Abstract

A coupled thermo–hydro–mechanical (THM) reservoir model of the Chingshui geothermal field was integrated with an organic Rankine cycle (ORC) model to assess long-term system performance under progressive reservoir cooling. A single-stage axial turbo-expander originally designed for R245fa was characterized through three-dimensional computational fluid dynamics simulations, and the resulting dataset trained an artificial neural network surrogate for predicting off-design mass flow rate, isentropic efficiency, and shaft power. Annually resolved reservoir temperatures from the THM model were sequentially introduced into the ORC model to evaluate off-design performance under pinch-temperature constraints over the plant lifetime. The feasibility of operating the same R245fa-designed hardware with the low-global-warming-potential (low-GWP) refrigerant R1234ze(Z) was assessed under identical configurations and degrading heat-source conditions. Over 30 years at 30 kg/s geothermal mass flow rate, both fluids followed comparable degradation trends, with the first-law efficiency of the total system declining by 18.19% for R245fa and 18.52% for R1234ze(Z). Despite comparable thermodynamic behavior, R1234ze(Z) achieved a lower levelized cost of electricity than R245fa by the 30th year. R1234ze(Z) delivered a turbo-expander total-to-static isentropic efficiency 1.84 percentage points higher than R245fa at 30 kg/s in the 30th year, corresponding to a relative difference of 2.26%, attributable to its lower Mach number. R1234ze(Z) is therefore identified as a promising low-GWP candidate for R245fa-designed geothermal ORC systems, although its direct drop-in feasibility without hardware modification remains subject to experimental verification. These findings highlight the importance of evaluating low-GWP refrigerants based on long-term off-design adaptability of existing hardware rather than design-condition performance alone.

Energy ReportsVol. 16
Industrial Technology Research Institute (TW), National Chin-Yi University of Technology (TW)
National Science and Technology Council
Affordable and clean energy, Climate action, Responsible consumption and production
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon