Numerical and Experimental Investigations of Heat Transfer and Pressure Drop for Twisted-Tube Heat Exchangers

Fluoride-salt-cooled high-temperature reactors and molten-salt reactors need compact, fouling-resistant primary-to-secondary heat exchangers that operate near atmospheric pressure at about 650 °C. Twisted tubes are a baffle-free, self-supporting candidate, but the available correlations cover narrow Reynolds number and modified Froude number windows and leave the shell side weakly characterized. Heat-transfer and friction correlations are developed for both sides of three stainless-steel twisted-tube heat exchangers, two of which differ only in twist pitch (101.6 and 76.2 mm) and one of which has a larger cross-section. Heat-transfer rates and pressure drops were measured in a counterflow water loop at 61 operating points, and the same geometries were modeled with steady Reynolds-averaged Navier–Stokes (RANS) simulations. Because the shell-side pressure drop, 4.6 to 25.7 Pa, fell below the transducer resolution and the measurements give only the overall thermal resistance, the Nusselt numbers and friction factors were reduced from the simulations, which the measurements were then used to test. The simulated values follow power laws in within 2.3% and 1.8% over tube-side from 14,000 to 50,000 and shell-side from 1560 to 3070. Shortening the pitch from 101.6 to 76.2 mm raises the shell-side and tube-side Nusselt numbers by 15% and 6% at equal , at the cost of 72% and 19% higher friction factors, and the tube-side Nusselt numbers of the long tubes exceed the smooth-tube value by 30 to 55%. The measured convective resistance agrees with the prediction in the median for Tube 1 and differs from it by 31% and 34% for Tubes 2 and 3, which is attributed to the energy imbalance between the streams. The measured tube-side friction factors are a constant 0.50 of the simulated values for the long tubes, a factor attributed to the shape of the inner cross-section of the formed tubes, which was not measured, so the friction correlations rest on the simulations. On a Reynolds-number basis the correlations lie within the band of published twisted-tube data. The correlations apply to the two cross-sections tested and within the stated ranges.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Engineering
Published
2026-11-24
DOI
https://doi.org/10.3390/jne7040068
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Numerical and Experimental Investigations of Heat Transfer and Pressure Drop for Twisted-Tube Heat Exchangers

Minghui Chen, Yuqi Liu, Braden S. Foderaro
1 links
Journal of Nuclear Engineering
Heat Transfer and Optimization
article

Numerical and Experimental Investigations of Heat Transfer and Pressure Drop for Twisted-Tube Heat Exchangers

Minghui Chen, Yuqi Liu, Braden S. Foderaro
article en

Abstract

Fluoride-salt-cooled high-temperature reactors and molten-salt reactors need compact, fouling-resistant primary-to-secondary heat exchangers that operate near atmospheric pressure at about 650 °C. Twisted tubes are a baffle-free, self-supporting candidate, but the available correlations cover narrow Reynolds number and modified Froude number windows and leave the shell side weakly characterized. Heat-transfer and friction correlations are developed for both sides of three stainless-steel twisted-tube heat exchangers, two of which differ only in twist pitch (101.6 and 76.2 mm) and one of which has a larger cross-section. Heat-transfer rates and pressure drops were measured in a counterflow water loop at 61 operating points, and the same geometries were modeled with steady Reynolds-averaged Navier–Stokes (RANS) simulations. Because the shell-side pressure drop, 4.6 to 25.7 Pa, fell below the transducer resolution and the measurements give only the overall thermal resistance, the Nusselt numbers and friction factors were reduced from the simulations, which the measurements were then used to test. The simulated values follow power laws in within 2.3% and 1.8% over tube-side from 14,000 to 50,000 and shell-side from 1560 to 3070. Shortening the pitch from 101.6 to 76.2 mm raises the shell-side and tube-side Nusselt numbers by 15% and 6% at equal , at the cost of 72% and 19% higher friction factors, and the tube-side Nusselt numbers of the long tubes exceed the smooth-tube value by 30 to 55%. The measured convective resistance agrees with the prediction in the median for Tube 1 and differs from it by 31% and 34% for Tubes 2 and 3, which is attributed to the energy imbalance between the streams. The measured tube-side friction factors are a constant 0.50 of the simulated values for the long tubes, a factor attributed to the shape of the inner cross-section of the formed tubes, which was not measured, so the friction correlations rest on the simulations. On a Reynolds-number basis the correlations lie within the band of published twisted-tube data. The correlations apply to the two cross-sections tested and within the stated ranges.

Journal of Nuclear EngineeringVol. 7(4)
University of New Mexico (US)
Office of Nuclear Energy
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon