Seismic resilience evaluation of power engineering structures considering near-fault ground motion effect

Near-fault ground motion (NFGM) can damage substation buildings and electrical equipment, disrupting equipment operation and delaying access for repair. However, the implications of joint building-equipment damage for post-earthquake functional recovery remain insufficiently understood. This study assesses the seismic resilience of a 220 kV building-equipment system using a coupled finite-element model subjected to 15 ordinary ground-motion (OGM) records and 15 NFGM records. Joint building-equipment damage states, incorporating building-dependent constraints on equipment operation and repair access, are retained for each record to simulate the post-earthquake functional recovery. For the selected records, NFGM generally produces higher fragility for the building, electrical cabinets, and transformers, whereas capacitor banks show no consistent increase. At a peak ground acceleration (PGA) of 0.2 g, the empirical probability of moderate-or-greater building damage increases from 33.33% under OGM to 100% under NFGM. Relative to OGM, mean initial composite functionality under NFGM is 78.34% lower at 0.2 g and falls to zero at 0.4 and 0.6 g. The corresponding relative reductions in the mean 30-day composite resilience index are 29.77%, 32.87%, and 12.41%, respectively. A comparison with unrestricted equipment operation and repair access further quantifies the influence of building-dependent constraints on recovery. Across all 30 records, these constraints reduce the mean 30-day composite resilience index by 11.29%, 38.31%, and 41.00% at 0.2, 0.4, and 0.6 g, respectively. The findings provide guidance for assessing the seismic resilience of substation systems.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2026-11-24
DOI
https://doi.org/10.1088/2631-8695/aec661
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seismic resilience evaluation of power engineering structures considering near-fault ground motion effect

Wanchen Meng, Liang Cheng, Yanhui Liu
1 links
Engineering Research Express
Seismic Performance and Analysis
article

Seismic resilience evaluation of power engineering structures considering near-fault ground motion effect

Wanchen Meng, Liang Cheng, Yanhui Liu
article en

Abstract

Near-fault ground motion (NFGM) can damage substation buildings and electrical equipment, disrupting equipment operation and delaying access for repair. However, the implications of joint building-equipment damage for post-earthquake functional recovery remain insufficiently understood. This study assesses the seismic resilience of a 220 kV building-equipment system using a coupled finite-element model subjected to 15 ordinary ground-motion (OGM) records and 15 NFGM records. Joint building-equipment damage states, incorporating building-dependent constraints on equipment operation and repair access, are retained for each record to simulate the post-earthquake functional recovery. For the selected records, NFGM generally produces higher fragility for the building, electrical cabinets, and transformers, whereas capacitor banks show no consistent increase. At a peak ground acceleration (PGA) of 0.2 g, the empirical probability of moderate-or-greater building damage increases from 33.33% under OGM to 100% under NFGM. Relative to OGM, mean initial composite functionality under NFGM is 78.34% lower at 0.2 g and falls to zero at 0.4 and 0.6 g. The corresponding relative reductions in the mean 30-day composite resilience index are 29.77%, 32.87%, and 12.41%, respectively. A comparison with unrestricted equipment operation and repair access further quantifies the influence of building-dependent constraints on recovery. Across all 30 records, these constraints reduce the mean 30-day composite resilience index by 11.29%, 38.31%, and 41.00% at 0.2, 0.4, and 0.6 g, respectively. The findings provide guidance for assessing the seismic resilience of substation systems.

Engineering Research Express
Guangzhou University (CN), China Southern Power Grid (China) (CN)
National Key Research and Development Program of China
Industry, innovation and infrastructure, Sustainable cities and communities
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Seismic resilience evaluation of power engineering structures considering near-fault ground motion effect — Wanchen Meng, Liang Cheng, et al. · Engineering Research Express (2026) | TGRS Research Map | TGRS