Installation-level quantification of the systematic difference in indoor LED lighting energy demand between the CIE 2° standard and CIE 10° supplementary photometric observers

Lighting design and regulation evaluate luminous flux with the CIE 2° standard photometric observer, V ( λ ), which weights short wavelengths less than the CIE 10° supplementary photometric observer, V 10 ( λ ). This study compares only these two CIE observers and quantifies how the choice between them changes the calculated energy demand of indoor LED lighting. For 979 phosphor-converted LED spectra (2700–6500 K), the luminous flux calculated with V ( λ ) was lower than that calculated with V 10 ( λ ) for every spectrum, by 5.30 % (2700 K) to 9.44 % (6500 K). Because illuminance is proportional to luminous flux, this difference carries over unchanged to installation level. For three EN 12464-1-compliant interiors with 4000 K and 6500 K luminaires, the energy difference was calculated as the reduction in installed luminous flux that still meets the illuminance target, assuming that the reduction is achieved by using fewer luminaires or, alternatively, by dimming. If the numerical targets are kept and only checked with V 10 ( λ ) (gross scenario), the full difference applies, allowing fewer luminaires in most installations. If the targets are first converted to V 10 ( λ ) using the incandescent and fluorescent sources under which they were established (net scenario), the difference falls to 1.1–4.4 %, achievable only by dimming.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-24
DOI
https://doi.org/10.1038/s41598-026-79196-5
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Installation-level quantification of the systematic difference in indoor LED lighting energy demand between the CIE 2° standard and CIE 10° supplementary photometric observers

Dorota Mozyrska, Maciej Listowski, Irena Fryc, Justyna Fryc et al.
2 links
Scientific Reports
Building Energy and Comfort Optimization
article

Installation-level quantification of the systematic difference in indoor LED lighting energy demand between the CIE 2° standard and CIE 10° supplementary photometric observers

Dorota Mozyrska, Maciej Listowski, Irena Fryc, Justyna Fryc, Robert Supronowicz
article en

Abstract

Lighting design and regulation evaluate luminous flux with the CIE 2° standard photometric observer, V ( λ ), which weights short wavelengths less than the CIE 10° supplementary photometric observer, V 10 ( λ ). This study compares only these two CIE observers and quantifies how the choice between them changes the calculated energy demand of indoor LED lighting. For 979 phosphor-converted LED spectra (2700–6500 K), the luminous flux calculated with V ( λ ) was lower than that calculated with V 10 ( λ ) for every spectrum, by 5.30 % (2700 K) to 9.44 % (6500 K). Because illuminance is proportional to luminous flux, this difference carries over unchanged to installation level. For three EN 12464-1-compliant interiors with 4000 K and 6500 K luminaires, the energy difference was calculated as the reduction in installed luminous flux that still meets the illuminance target, assuming that the reduction is achieved by using fewer luminaires or, alternatively, by dimming. If the numerical targets are kept and only checked with V 10 ( λ ) (gross scenario), the full difference applies, allowing fewer luminaires in most installations. If the targets are first converted to V 10 ( λ ) using the incandescent and fluorescent sources under which they were established (net scenario), the difference falls to 1.1–4.4 %, achievable only by dimming.

Scientific Reports
Bialystok University of Technology (PL), Medical University of Białystok (PL)
Politechnika Bialostocka
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon