Calibrated for the Winter, Not for the Cold Snap: Chronological Evidence from 38 Extreme-Cold Events in Six U.S. Power Systems
Probabilistic load forecasts are validated over whole seasons, yet power systems are stressed in rare cold events. We test whether conformal 90% intervals calibrated on earlier winters remain calibrated in the next extreme-cold event, using only information available at issuance. Across 38 events in six U.S. systems, intervals around a gradient-boosting forecaster cover 0.64 of event hours against 0.84 of winter hours, a gap of 20.3 percentage points (95% interval 10.0–30.5 over 15 cold outbreaks). Intervals around the operators' own, more accurate day-ahead forecasts show a gap of 18.2 points (12.8–23.6). Most misses lie above the interval, and both a displaced median forecast and excess dispersion contribute. Recalibration selected on other events repairs 3 of 23 large-gap events; calibrating on earlier cold events restores coverage only by widening intervals 1.87-fold. Seasonal calibration does not certify event calibration.
Authors
- Dresden Goehner
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-23
- DOI
- https://doi.org/10.5281/zenodo.24490220
- Primary Topic
- Energy Load and Power Forecasting
- Type
- preprint