Soft tissue and crestal bone level assessment in implants with platform-switched Morse Taper connections with implant-abutment interface placed subcrestally – a clinical trial

Context: The location of the implant abutment interface is of major importance for constructing esthetic dental implant restorations with a proper emergence profile. Subcrestally placed implants may also partially compensate for thin mucosal phenotypes. Aims To determine proximal crestal bone levels in subcrestally placed platform-switched implants with 160 Morse Taper connections at least 6 months after implantation. Settings and Design: This prospective follow-up clinical study is performed at XYZ Institute of Dental Sciences & Research, affiliated with a Health University, after taking Institutional Ethical Committee approval. Methods and Materials: 19 subjects requiring single- or multiple-tooth rehabilitation were included who were > 18 years old, ASA Grade I or II, with no bone metabolic diseases and adequate bone volume for placement of a standard implant. Subjects with uncontrolled diabetes, poor oral hygiene, unstable periodontitis, and not willing to give consent were excluded. Tapered implants with a platform-switch and a deep 16 0 Morse taper, including an internal indexation, were subcrestally placed 1–4 mm in a flapped approach using a conventional two-stage protocol. Three to four months later, after uncovering, they were restored. Clinical and radiographic parameters were assessed preoperatively, immediately after implant placement (T0), at the second stage, at the time of prosthesis delivery (T1) and 6 months to 2 years after loading (T2). Statistical analysis used: Windows-based software Stata version 13.1 (StataCorp, College Station, TX, USA). Descriptive statistics summarised the demographic and clinical characteristics. The changes in mesial and distal bone levels over time points (T0, T1, T2), a paired t-test was used. The relationship between implant placement depth and marginal bone levels was analysed using Pearson’s correlation coefficient (r). Results A total of 26 implants were placed and evaluated over 6 months to 2 years. The average radiographic depth of the implant at T0, T1 and T2 was 1.91 ± 0.83, 1.78 ± 0.86 and − 0.03 ± 1.60 mm, respectively. The values between T0 to T2 were statistically highly significant (p < 0.0001). Pearson’s correlation between clinical depth of implant placement and radiographic bone levels at T2 showed strong linear positive correlation (r = 0.662, p < 0.001). Conclusions Within the limitations of the study, we can conclude that, there is linear positive correlation between subcrestal depth of implant placement and presence of marginal bone around implants 6 months to 2 years after implantation in platform-switched implants with 16 degree morse tapers.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-24
DOI
https://doi.org/10.21203/rs.3.rs-11822444/v1
Primary Topic
Dental Implant Techniques and Outcomes
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Soft tissue and crestal bone level assessment in implants with platform-switched Morse Taper connections with implant-abutment interface placed subcrestally – a clinical trial

Vishnudas Dwarkadas Bhandari, Om Nemichand Baghele, Gauri Mahesh Ugale, Shital Chandraprakash Nagime et al.
1 links
Research Square
Dental Implant Techniques and Outcomes
preprint

Soft tissue and crestal bone level assessment in implants with platform-switched Morse Taper connections with implant-abutment interface placed subcrestally – a clinical trial

Vishnudas Dwarkadas Bhandari, Om Nemichand Baghele, Gauri Mahesh Ugale, Shital Chandraprakash Nagime, Raghavendra Metri, Anusha Arvind Math, Sayli Shankarrao Dalvi
preprint en

Abstract

Context: The location of the implant abutment interface is of major importance for constructing esthetic dental implant restorations with a proper emergence profile. Subcrestally placed implants may also partially compensate for thin mucosal phenotypes. Aims To determine proximal crestal bone levels in subcrestally placed platform-switched implants with 160 Morse Taper connections at least 6 months after implantation. Settings and Design: This prospective follow-up clinical study is performed at XYZ Institute of Dental Sciences & Research, affiliated with a Health University, after taking Institutional Ethical Committee approval. Methods and Materials: 19 subjects requiring single- or multiple-tooth rehabilitation were included who were > 18 years old, ASA Grade I or II, with no bone metabolic diseases and adequate bone volume for placement of a standard implant. Subjects with uncontrolled diabetes, poor oral hygiene, unstable periodontitis, and not willing to give consent were excluded. Tapered implants with a platform-switch and a deep 16 0 Morse taper, including an internal indexation, were subcrestally placed 1–4 mm in a flapped approach using a conventional two-stage protocol. Three to four months later, after uncovering, they were restored. Clinical and radiographic parameters were assessed preoperatively, immediately after implant placement (T0), at the second stage, at the time of prosthesis delivery (T1) and 6 months to 2 years after loading (T2). Statistical analysis used: Windows-based software Stata version 13.1 (StataCorp, College Station, TX, USA). Descriptive statistics summarised the demographic and clinical characteristics. The changes in mesial and distal bone levels over time points (T0, T1, T2), a paired t-test was used. The relationship between implant placement depth and marginal bone levels was analysed using Pearson’s correlation coefficient (r). Results A total of 26 implants were placed and evaluated over 6 months to 2 years. The average radiographic depth of the implant at T0, T1 and T2 was 1.91 ± 0.83, 1.78 ± 0.86 and − 0.03 ± 1.60 mm, respectively. The values between T0 to T2 were statistically highly significant (p < 0.0001). Pearson’s correlation between clinical depth of implant placement and radiographic bone levels at T2 showed strong linear positive correlation (r = 0.662, p < 0.001). Conclusions Within the limitations of the study, we can conclude that, there is linear positive correlation between subcrestal depth of implant placement and presence of marginal bone around implants 6 months to 2 years after implantation in platform-switched implants with 16 degree morse tapers.

Research Square
Maharashtra Institute of Dental Science and Research (IN)
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon