A non-contact alternating magnetic field imaging system based on diamond nitrogen-vacancy color centers

Purpose This study aims to present a non-contact alternating-current (AC) magnetic-field imaging system based on diamond nitrogen-vacancy (NV) centers that reduces dependence on external arbitrary waveform generators and lock-in amplifiers. Design/methodology/approach Fixed-frequency optically detected magnetic resonance was implemented with an STM32F1 microcontroller, which generates a 1 kHz excitation, triggers synchronous ADC acquisition, constructs a phase-coherent reference and performs in-phase/quadrature software lock-in demodulation. Straight, L-shaped and antiparallel printed circuit board traces provided validation. Findings At 1 kHz, the system achieved 6.54 nT/Hz1/2 sensitivity and a 56 dB usable dynamic range. The measured profile had a 3.8 mm full width at half maximum at a 1 mm stand-off. Reconstructed maps reproduced the features of the NV-axis-projected Biot-Savart model. Research limitations/implications The system measures only the magnetic-field projection along one NV axis and its effective lateral response depends on probe geometry, stand-off distance and scan interval. Validation was limited to controlled test traces. Practical implications Replacing the external waveform generator and lock-in amplifier in the low-frequency excitation and demodulation chain provides a lower-cost basis for circuit-board magnetic-field imaging. The laser, microwave source, scanning stage and host computer remain external. Originality/value Low-frequency excitation, synchronous acquisition and digital lock-in demodulation are integrated on one general-purpose microcontroller and demonstrated in two-dimensional NV-center magnetic-field imaging.

Authors

Institutions

Publication Details

Journal
Sensor Review
Published
2026-11-25
DOI
https://doi.org/10.1108/sr-07-2026-0757
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A non-contact alternating magnetic field imaging system based on diamond nitrogen-vacancy color centers

Shuangquan Ran, Xin Bai, Kun Huang, Long Chen et al.
1 links
Sensor Review
Diamond and Carbon-based Materials Research
article

A non-contact alternating magnetic field imaging system based on diamond nitrogen-vacancy color centers

Shuangquan Ran, Xin Bai, Kun Huang, Long Chen, Tao Hu
article en

Abstract

Purpose This study aims to present a non-contact alternating-current (AC) magnetic-field imaging system based on diamond nitrogen-vacancy (NV) centers that reduces dependence on external arbitrary waveform generators and lock-in amplifiers. Design/methodology/approach Fixed-frequency optically detected magnetic resonance was implemented with an STM32F1 microcontroller, which generates a 1 kHz excitation, triggers synchronous ADC acquisition, constructs a phase-coherent reference and performs in-phase/quadrature software lock-in demodulation. Straight, L-shaped and antiparallel printed circuit board traces provided validation. Findings At 1 kHz, the system achieved 6.54 nT/Hz1/2 sensitivity and a 56 dB usable dynamic range. The measured profile had a 3.8 mm full width at half maximum at a 1 mm stand-off. Reconstructed maps reproduced the features of the NV-axis-projected Biot-Savart model. Research limitations/implications The system measures only the magnetic-field projection along one NV axis and its effective lateral response depends on probe geometry, stand-off distance and scan interval. Validation was limited to controlled test traces. Practical implications Replacing the external waveform generator and lock-in amplifier in the low-frequency excitation and demodulation chain provides a lower-cost basis for circuit-board magnetic-field imaging. The laser, microwave source, scanning stage and host computer remain external. Originality/value Low-frequency excitation, synchronous acquisition and digital lock-in demodulation are integrated on one general-purpose microcontroller and demonstrated in two-dimensional NV-center magnetic-field imaging.

Sensor Review
Southwest University of Science and Technology (CN), North University of China (CN)
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon